B<br />
Floor/Ceilings<br />
Steel Framed<br />
3 Hour <strong>Fire</strong>-rated Construction Steel Bar Joist Framing (Refer to ULC/UL Design Directory listings for loading conditions. See page 6.) Acoustical Performance Reference<br />
Construction Detail Description Test Number STC Test Number ARL Index<br />
clg. wt. 3, clg. wt. 4 • 15.9 mm (5/8�)SHEETROCK FIRECODE C Core ULC Des G512 <strong>SA</strong>920 B-32<br />
Gypsum Panels or UL Des G512<br />
406 mm<br />
(16")<br />
– metal fur channel 610 mm (24�) o.c.<br />
– joints finished<br />
– 64 mm (2-1/2�) concrete on corrugated steel deck<br />
or riblath<br />
– steel bar joists, 610 mm (24�) o.c.<br />
• optional veneer plaster<br />
clg. wt. 3 • <strong>CGC</strong> DGL Drywall Suspension System UL Des G529 SC2000 B-33<br />
• 12.7 mm (1/2�) or 15.9 mm (5/8�)SHEETROCK<br />
FIRECODE C Core Gypsum Panels<br />
540 mm<br />
(21 1 ⁄4")<br />
624 mm<br />
(24 9 ⁄16")<br />
min.<br />
584 mm<br />
(23")<br />
543 mm<br />
(21 3 ⁄8")<br />
572 mm<br />
(22 1 ⁄2")<br />
– joints finished<br />
– 81 mm (3-1/4�) concrete on riblath or corrugated<br />
steel deck<br />
– steel bar joists, 610 mm (24�) o.c.<br />
• 15.9 mm (5/8�) or 19.1 mm (3/4�) FR-83 or FR-X1 UL Des G205 DXLA, DXLZA or SDXLA Susp Exp Grid SC2000 B-34<br />
or 12.7 mm (1/2�) or 15.9 mm (5/8�) FR-4 or 12.7 mm<br />
(1/2�) FC-CB or Astro-FR acoustical ceiling panels<br />
• DXL, DXLZ, or SDXL Susp Exp Grid System<br />
– light fixture and air duct optional<br />
– 89 mm (3-1/2�) concrete deck on riblath<br />
– steel bar joists, 1200 mm (4�) o.c.<br />
• 15.9 mm (5/8�) or 19.1 mm (3/4�) FR-83 or 19.1 mm (3/4�) UL Des G211 DXLA, DXLZA, SDXLA or ZXLA Susp Exp SC2000 B-35<br />
FR-X1, Astro-FR or FR-4 acoustical ceiling panels<br />
Grid Syst may be used instead, but fire<br />
• DXL, DXLA, DXLZ, DXLZA, SDXL, SDXLA or<br />
rating is limited to 2-hr.; 12.7 mm (1/2�)<br />
ZXLA Susp Exp Grid System<br />
FC-CB gypsum panels may be used as a<br />
– light fixture and air duct optional<br />
– 75 mm (3�) concrete deck used instead, but fire rating<br />
is limited to 2-hr.; 13 mm (1/2�) on riblath<br />
– steel bar joists, 610 mm (24�) o.c.<br />
ceiling panel for fire rating of 1-hr.<br />
• 15.9 mm (5/8�) FR-81; 15.9 mm (5/8�) or UL Des G213 When FR-4 or M clg panels are used, the fire SC2000 B-36<br />
19.1 mm (3/4�) FR-83; 19.1 mm (3/4�) FR-X1; or<br />
rating is limited to 2-hr.; 12.7 mm (1/2�)<br />
12.7 mm (1/2�) FC-CB; or 15.9 mm (5/8�) FR-4; or<br />
FC-CB gypsum panels may be used as a<br />
19.1 mm (3/4�) Astro-FR acoustical ceiling panels<br />
• DXL, DXLZ or SDXL Susp Exp Grid System<br />
– light fixture and air duct optional<br />
– 89 mm (3-1/2�) concrete deck on riblath or steel deck<br />
(increase concrete 13 mm (1/2�))<br />
– steel bar joists, 610 mm (24�) o.c.<br />
ceiling panel for fire ratings of 1- or 1-1/2-hr.<br />
31 <strong>CGC</strong> <strong>Fire</strong>-<strong>Resistant</strong> <strong>Assemblies</strong><br />
Syst may be used instead, but fire rating<br />
is limited to 2-hr.; DXLT, DXLTA, DXLTZ<br />
or DXLTZA Susp Exp Grid Syst may be<br />
also used, but fire rating is limited to<br />
1-1/2-hr.; 12.7 mm (1/2�) FC-CB gypsum<br />
panels may be used as a ceiling panel for<br />
fire ratings of 1 or 1-1/2-hr.