Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

B<br />

Floor/Ceilings<br />

Steel Framed<br />

3 Hour <strong>Fire</strong>-rated Construction Steel Bar Joist Framing (Refer to ULC/UL Design Directory listings for loading conditions. See page 6.) Acoustical Performance Reference<br />

Construction Detail Description Test Number STC Test Number ARL Index<br />

clg. wt. 3, clg. wt. 4 • 15.9 mm (5/8�)SHEETROCK FIRECODE C Core ULC Des G512 <strong>SA</strong>920 B-32<br />

Gypsum Panels or UL Des G512<br />

406 mm<br />

(16")<br />

– metal fur channel 610 mm (24�) o.c.<br />

– joints finished<br />

– 64 mm (2-1/2�) concrete on corrugated steel deck<br />

or riblath<br />

– steel bar joists, 610 mm (24�) o.c.<br />

• optional veneer plaster<br />

clg. wt. 3 • <strong>CGC</strong> DGL Drywall Suspension System UL Des G529 SC2000 B-33<br />

• 12.7 mm (1/2�) or 15.9 mm (5/8�)SHEETROCK<br />

FIRECODE C Core Gypsum Panels<br />

540 mm<br />

(21 1 ⁄4")<br />

624 mm<br />

(24 9 ⁄16")<br />

min.<br />

584 mm<br />

(23")<br />

543 mm<br />

(21 3 ⁄8")<br />

572 mm<br />

(22 1 ⁄2")<br />

– joints finished<br />

– 81 mm (3-1/4�) concrete on riblath or corrugated<br />

steel deck<br />

– steel bar joists, 610 mm (24�) o.c.<br />

• 15.9 mm (5/8�) or 19.1 mm (3/4�) FR-83 or FR-X1 UL Des G205 DXLA, DXLZA or SDXLA Susp Exp Grid SC2000 B-34<br />

or 12.7 mm (1/2�) or 15.9 mm (5/8�) FR-4 or 12.7 mm<br />

(1/2�) FC-CB or Astro-FR acoustical ceiling panels<br />

• DXL, DXLZ, or SDXL Susp Exp Grid System<br />

– light fixture and air duct optional<br />

– 89 mm (3-1/2�) concrete deck on riblath<br />

– steel bar joists, 1200 mm (4�) o.c.<br />

• 15.9 mm (5/8�) or 19.1 mm (3/4�) FR-83 or 19.1 mm (3/4�) UL Des G211 DXLA, DXLZA, SDXLA or ZXLA Susp Exp SC2000 B-35<br />

FR-X1, Astro-FR or FR-4 acoustical ceiling panels<br />

Grid Syst may be used instead, but fire<br />

• DXL, DXLA, DXLZ, DXLZA, SDXL, SDXLA or<br />

rating is limited to 2-hr.; 12.7 mm (1/2�)<br />

ZXLA Susp Exp Grid System<br />

FC-CB gypsum panels may be used as a<br />

– light fixture and air duct optional<br />

– 75 mm (3�) concrete deck used instead, but fire rating<br />

is limited to 2-hr.; 13 mm (1/2�) on riblath<br />

– steel bar joists, 610 mm (24�) o.c.<br />

ceiling panel for fire rating of 1-hr.<br />

• 15.9 mm (5/8�) FR-81; 15.9 mm (5/8�) or UL Des G213 When FR-4 or M clg panels are used, the fire SC2000 B-36<br />

19.1 mm (3/4�) FR-83; 19.1 mm (3/4�) FR-X1; or<br />

rating is limited to 2-hr.; 12.7 mm (1/2�)<br />

12.7 mm (1/2�) FC-CB; or 15.9 mm (5/8�) FR-4; or<br />

FC-CB gypsum panels may be used as a<br />

19.1 mm (3/4�) Astro-FR acoustical ceiling panels<br />

• DXL, DXLZ or SDXL Susp Exp Grid System<br />

– light fixture and air duct optional<br />

– 89 mm (3-1/2�) concrete deck on riblath or steel deck<br />

(increase concrete 13 mm (1/2�))<br />

– steel bar joists, 610 mm (24�) o.c.<br />

ceiling panel for fire ratings of 1- or 1-1/2-hr.<br />

31 <strong>CGC</strong> <strong>Fire</strong>-<strong>Resistant</strong> <strong>Assemblies</strong><br />

Syst may be used instead, but fire rating<br />

is limited to 2-hr.; DXLT, DXLTA, DXLTZ<br />

or DXLTZA Susp Exp Grid Syst may be<br />

also used, but fire rating is limited to<br />

1-1/2-hr.; 12.7 mm (1/2�) FC-CB gypsum<br />

panels may be used as a ceiling panel for<br />

fire ratings of 1 or 1-1/2-hr.