Limiting Heights Table<br />
;<br />
;<br />
Typical table 2 Stud Stud Allow. Partition, Partition, Furring,<br />
limiting<br />
heights—<br />
Interior<br />
partitions<br />
width spacing defl. one layer two layers one layer<br />
;; ;;<br />
;; ;; ;;<br />
25-gauge stud (.0179 min.)<br />
400 mm L/120 3277 f 3277 d 3124 d<br />
L/240 2896 d 3200 d 2515 d<br />
41 mm L/360 2515 d 2743 d 2210 d<br />
600 mm L/120 2667 f 2667 f 2667 f<br />
L/240 2515 d 2667 f 2210 d<br />
L/360 2210 d 2438 d 1095 d<br />
400 mm L/120 4191 f 4191 f 4191 d*<br />
L/240 3810 d 4191 d 3353 d<br />
64 mm L/360 3277 d 3581 d 2972 d<br />
600 mm L/120 3429 f 3429 f 3429 f<br />
L/240 3277 d 3429 f 2972 d<br />
L/360 2896 d 3124 d 2591 d<br />
400 mm L/120 5105 f 5105 f 5105 f*<br />
L/240 4877 d 5105 f 4420 d*<br />
92 mm L/360 4267 d 4496 d 3886 d*<br />
600 mm L/120 4115 f 4115 f 4115 f*<br />
L/240 4115 f 4115 f 3886 d*<br />
L/360 3734 d 3962 d 3353 d<br />
400 mm L/120 6096 f 6096 f 6096 f*<br />
L/240 6096 f 6096 f 6096 f*<br />
152 mm L/360 6096 f 6096 f 5715 f*<br />
600 mm L/120 4572 v 4572 v 4572 v*<br />
L/240 4572 v 4572 v 4572 v*<br />
L/360 4572 v 4572 v 4572 v*<br />
20 gauge stud (.0312 min.)<br />
400 mm L/120 5282 f 5462 f 5029 d*<br />
L/240 4215 d 4901 d 3962 d*<br />
64 mm L/360 3658 d 4267 d 3505 d<br />
600 mm L/120 4444 f 4444 f 4420 d*<br />
L/240 3658 d 4090 f 3505 d<br />
L/360 3200 d 3758 d 3048 d<br />
400 mm L/120 6882 d 7215 f 6629 d*<br />
L/240 5462 d 6148 d 5258 d*<br />
92 mm L/360 4749 d 5386 d 4572 d*<br />
600 mm L/120 5892 f 5892 f 5791 d*<br />
L/240 4749 d 5386 f 4572 d*<br />
L/360 4167 d 4724 d 4039 d*<br />
400 mm L/120 <strong>100</strong>34 d 10339 f 9805 d*<br />
L/240 7949 d 8687 d 7772 d*<br />
152 mm L/360 8959 d 7596 d 7087 d*<br />
600 mm L/120 7696 f 7696 f 8534 d*<br />
L/240 6956 d 7596 d 6782 d*<br />
L/360 6072 d 6654 d 5944 d*<br />
73 <strong>CGC</strong> <strong>Fire</strong>-<strong>Resistant</strong> <strong>Assemblies</strong><br />
Stud Stud Allow. Partition, Partition, Furring,<br />
width spacing defl. one layer two layers one layer<br />
25-gauge stud (.0179 min.)<br />
16� L/120 10�9� f 10�9� d 10�3� d<br />
L/240 9�6� d 10�6� d 8�3� d<br />
1-5/8� L/360 8�3� d 9�0� d 7�3� d<br />
24� L/120 8�9� f 8�9� f 8�9� f<br />
L/240 8�3� d 8�9� f 7�3� d<br />
L/360 7�3� d 8�0� d 6�3� d<br />
16� L/120 13�9� f 13�9� f 13�9� d*<br />
L/240 12�6� d 13�6� d 11�0� d<br />
2-1/2� L/360 10�9� d 11�9� d 9�9� d<br />
24� L/120 11�3� f 11�3� f 11�3� f<br />
L/240 10�9� d 11�3� f 9�9� d<br />
L/360 9�6� d 10�3� d 8�6� d<br />
16� L/120 16�9� f 16�9� f 16�9� f*<br />
L/240 16�0� d 16�9� f 14�6� d*<br />
3-5/8� L/360 14�0� d 14�9� d 12�9� d*<br />
24� L/120 13�6� f 13�6� f 13�6� f*<br />
L/240 13�6� f 13�6� f 12�9� d*<br />
L/360 12�3� d 13�0� d 11�0� d<br />
16� L/120 20�0� f 20�0� f 20�0� f*<br />
L/240 20�0� f 20�0� f 20�0� f*<br />
6� L/360 20�0� f 20�0� f 18�9� f*<br />
24� L/120 15�0� v 15�0� v 15�0� v*<br />
L/240 15�0� v 15�0� v 15�0� v*<br />
L/360 15�0� v 15�0� v 15�0� v*<br />
20 gauge stud (.0312 min.)<br />
16� L/120 17�4� f 17�11� f 16�6� d*<br />
L/240 13�10� d 16�1� d 13�0� d*<br />
2-1/2� L/360 12�0� d 14�0� d 11�6� d<br />
24� L/120 14�7� f 14�7� f 14�6� d*<br />
L/240 12�0� d 13�5� f 11�6� d<br />
L/360 10�6� d 12�4� d 10�0� d<br />
16� L/120 22�7� d 23�8� f 21�9� d*<br />
L/240 17�11� d 20�2� d 17�3� d*<br />
3-5/8� L/360 15�7� d 17�8� d 15�0� d*<br />
24� L/120 19�4� f 19�4� f 19�0� d*<br />
L/240 15�7� d 17�8� f 15�0 �d*<br />
L/360 13�8� d 15�6� d 13�3 �d*<br />
16� L/120 32�11� d 33�11� f 32�3� d*<br />
L/240 26�1� d 28�6� d 25�6� d*<br />
6� L/360 22�10� d 24�11� d 23�3� d*<br />
24� L/120 25�3� f 25�3� f 28�0� d*<br />
L/240 22�10� d 24�11� d 22�3� d*<br />
L/360 19�11� d 21�10� d 19�6� d*<br />
Notice: The Limiting Heights tables are based primarily on typical minimum physical and<br />
structural properties (I x and S x ). Physical and structural properties may vary by region and<br />
manufacturer. Request actual physical and structural property data from your local steel<br />
framing manufacturer. Limiting criteria: d-deflection; f-bending stress, v-end reaction<br />
shear.<br />
* Studs exceeding 3660 mm (12 ft.) require mid-height anchor to exterior wall.<br />
;<br />
;<br />
;; ;;<br />
;; ;; ;;