B<br />
Floor/Ceilings<br />
Structural Concrete<br />
1-1/2 Hour <strong>Fire</strong>-rated Construction (Refer to ULC/UL Design Directory listings for loading conditions. See page 6.) Acoustical Performance Reference<br />
Construction Detail Description Test Number STC Test Number ARL Index<br />
416 mm<br />
(16 3 ⁄8")<br />
2 Hour <strong>Fire</strong>-rated Construction<br />
• 15.9 mm (5/8�) FR-4, M or FR-81; 15.9 mm (5/8�) UL Des D209 SC2000 B-75<br />
or 19.1 mm (3/4�) FR-83; or 19.1 mm (3/4�)<br />
FR-X1 acoust ceiling panels or 12.7 mm (1/2�)<br />
FC-CB gypsum lay-in tile<br />
• DXL, DXLA, DXLZ, DXLZA, SDXL, SDXLA or<br />
ZXLA Susp Exp Grid System<br />
– light fixture and speakers optional<br />
– 64 mm (2-1/2�) concrete on fluted or cellular steel deck<br />
clg. wt. 3 • 15.9 mm (5/8�)SHEETROCK FIRECODE C UL Des J502, <strong>SA</strong>305 B-76<br />
Core Gypsum Panels J503<br />
241 mm<br />
(9 1 ⁄2")<br />
216 mm<br />
(8 1 ⁄2")<br />
222 mm<br />
(8 3 ⁄4")<br />
– metal furring channel 610 mm (24�) o.c.<br />
– joints finished<br />
– 50 mm (2�) precast normal weight (J502) or<br />
lightweight (UL Des J503) concrete units with<br />
150 mm (6�) deep stems 1200 mm (48�) o.c.<br />
• <strong>CGC</strong> DGL Drywall Suspension System<br />
(UL Des J502)<br />
• 12.7 mm (1/2�)LEVELROCK Floor Underlayment UL Des J991 <strong>SA</strong>305 B-77<br />
• optional SRM-25 or SRB sound mat<br />
– 200 mm (8�) minimum thick normal weight precast<br />
concrete units<br />
• 12.7 mm (1/2�)LEVELROCK Floor Underlayment UL Des J994 <strong>SA</strong>305 B-78<br />
– 200 mm (8�) minimum thick light weight precast<br />
concrete units<br />
clg. wt. 3 • 15.9 mm (5/8�)SHEETROCK FIRECODE Core GA-FC-2120 <strong>SA</strong>305 B-79<br />
Gypsum Panels<br />
– metal furring channel 610 mm (24�) o.c.<br />
– joints finished<br />
– joist leg 250 mm (10�) deep<br />
356 mm<br />
(14")<br />
619 mm<br />
(24 3 ⁄8")<br />
• 19.1 mm (3/4�) FR-83 acoust ceiling panels UL Des D215 SC2000 B-80<br />
• DXL, DXLZ or SDXL Susp Exp Grid System<br />
– light fixture and air duct optional<br />
– 64 mm (2-1/2�) concrete deck deck on fluted or<br />
cellular steel floor<br />
41 <strong>CGC</strong> <strong>Fire</strong>-<strong>Resistant</strong> <strong>Assemblies</strong>