24.02.2013 Views

Fire-Resistant Assemblies SA-100 - CGC

Fire-Resistant Assemblies SA-100 - CGC

Fire-Resistant Assemblies SA-100 - CGC

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

B<br />

Floor/Ceilings<br />

Structural Concrete<br />

1-1/2 Hour <strong>Fire</strong>-rated Construction (Refer to ULC/UL Design Directory listings for loading conditions. See page 6.) Acoustical Performance Reference<br />

Construction Detail Description Test Number STC Test Number ARL Index<br />

416 mm<br />

(16 3 ⁄8")<br />

2 Hour <strong>Fire</strong>-rated Construction<br />

• 15.9 mm (5/8�) FR-4, M or FR-81; 15.9 mm (5/8�) UL Des D209 SC2000 B-75<br />

or 19.1 mm (3/4�) FR-83; or 19.1 mm (3/4�)<br />

FR-X1 acoust ceiling panels or 12.7 mm (1/2�)<br />

FC-CB gypsum lay-in tile<br />

• DXL, DXLA, DXLZ, DXLZA, SDXL, SDXLA or<br />

ZXLA Susp Exp Grid System<br />

– light fixture and speakers optional<br />

– 64 mm (2-1/2�) concrete on fluted or cellular steel deck<br />

clg. wt. 3 • 15.9 mm (5/8�)SHEETROCK FIRECODE C UL Des J502, <strong>SA</strong>305 B-76<br />

Core Gypsum Panels J503<br />

241 mm<br />

(9 1 ⁄2")<br />

216 mm<br />

(8 1 ⁄2")<br />

222 mm<br />

(8 3 ⁄4")<br />

– metal furring channel 610 mm (24�) o.c.<br />

– joints finished<br />

– 50 mm (2�) precast normal weight (J502) or<br />

lightweight (UL Des J503) concrete units with<br />

150 mm (6�) deep stems 1200 mm (48�) o.c.<br />

• <strong>CGC</strong> DGL Drywall Suspension System<br />

(UL Des J502)<br />

• 12.7 mm (1/2�)LEVELROCK Floor Underlayment UL Des J991 <strong>SA</strong>305 B-77<br />

• optional SRM-25 or SRB sound mat<br />

– 200 mm (8�) minimum thick normal weight precast<br />

concrete units<br />

• 12.7 mm (1/2�)LEVELROCK Floor Underlayment UL Des J994 <strong>SA</strong>305 B-78<br />

– 200 mm (8�) minimum thick light weight precast<br />

concrete units<br />

clg. wt. 3 • 15.9 mm (5/8�)SHEETROCK FIRECODE Core GA-FC-2120 <strong>SA</strong>305 B-79<br />

Gypsum Panels<br />

– metal furring channel 610 mm (24�) o.c.<br />

– joints finished<br />

– joist leg 250 mm (10�) deep<br />

356 mm<br />

(14")<br />

619 mm<br />

(24 3 ⁄8")<br />

• 19.1 mm (3/4�) FR-83 acoust ceiling panels UL Des D215 SC2000 B-80<br />

• DXL, DXLZ or SDXL Susp Exp Grid System<br />

– light fixture and air duct optional<br />

– 64 mm (2-1/2�) concrete deck deck on fluted or<br />

cellular steel floor<br />

41 <strong>CGC</strong> <strong>Fire</strong>-<strong>Resistant</strong> <strong>Assemblies</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!