C<br />

Roof/Ceilings<br />

Steel Framed<br />

1 Hour <strong>Fire</strong>-rated Construction Steel Truss (Refer to ULC/UL Design Directory listings for loading conditions. See page 6.) Acoustical Performance Reference<br />

Construction Detail Description Test Number STC Test Number ARL Index<br />

clg. wt. 3 • 15.9 mm (5/8�) SHEETROCK FIRECODE C UL Des P524 C-24<br />

Core Gypsum Panels<br />

– Resilient channels<br />

– joints finished<br />

– insulation optional in concealed space directly<br />

over gypsum ceiling membrane<br />

– roof covering and roof insulation<br />

– steel roof deck<br />

– minimum 302 mm (11-7/8�) deep steel roof<br />

truss 1200 mm (48�) o.c.<br />

clg. wt. 3 • 15.9 mm (5/8�) SHEETROCK FIRECODE C UL Des P521, C-25<br />

Core Gypsum Panels P525, P527, P529<br />

– Resilient channels<br />

– joints finished<br />

– steel roof deck<br />

– steel truss 1200 mm (48�) o.c.<br />

• roof covering and roof insulation over 13 mm (1/2�)<br />

DUROCK Cement Board or 12.7 mm (1/2�)<br />

SHEETROCK Gypsum Panels<br />

clg. wt. 3 • 15.9 mm (5/8�) SHEETROCK FIRECODE C UL Des P523, C-26<br />

Core Gypsum Panels P526, P528, P530<br />

– Resilient channels<br />

– joints finished<br />

– insulation optional in concealed space directly<br />

over gypsum ceiling membrane<br />

– 18 mm (23/32�) thick plywood decking<br />

– steel truss 1200 mm (48�) o.c.<br />

clg. wt. 3 • 15.9 mm (5/8�) SHEETROCK FIRECODE C UL Des P522 C-27<br />

Core Gypsum Panels<br />

– 13 mm (1/2�) plywood sheathing<br />

– pitched or parallel chord wood trusses, 610 mm (24�) o.c.<br />

– air duct<br />

– ceiling damper<br />

– optional insulation<br />

– Resilient channel, 400 mm (16�) o.c.<br />

without insulation, 300 mm (12�) o.c. with insulation<br />

• optional <strong>CGC</strong> DGL Drywall Suspension System<br />

– joints finished<br />