B<br />

Floor/Ceilings<br />

Wood Framed<br />

2 Hour <strong>Fire</strong>-rated Construction Dimensional Lumber (Refer to ULC/UL Design Directory listings for loading conditions. See page 6.) Acoustical Performance Reference<br />

Construction Detail Description Test Number STC IIC Test Number ARL Index<br />

clg. wt. 5 • 2 layers 15.9 mm (5/8�) SHEETROCK FIRECODE ULC Des L511 Assembly not recommended B-58<br />

C Core Gypsum Panels or UL Des L511 when sound control is a major<br />

– 25 mm (1�) nominal wood sub and finished floor consideration.<br />

349 mm<br />

(13 3 ⁄4")<br />

337 mm<br />

(13 1 ⁄4")<br />

330 mm<br />

(13")<br />

330 mm<br />

(13")<br />

311 mm<br />

(12 1 ⁄4")<br />

– 2x10 wood joist 400 mm (16�) o.c.<br />

– Resilient channel<br />

– joints finished<br />

• 2 layers 15.9 mm (5/8�) SHEETROCK FIRECODE UL Des L541 52 RAL-IN-89-5<br />

<strong>SA</strong>934 B-59<br />

C Core Gypsum Panels<br />

– 200 x 200 mm (8� x 8�) ceramic tile<br />

• 12.7 mm (1/2�) DUROCK Exterior Cement Board<br />

• 25.4 mm (1�) SHEETROCK Gypsum Liner Panels<br />

– 13 mm (1/2�) plywood<br />

– 2x10 wood joist 400 mm (16�) o.c.<br />

– 75 mm (3�) mineral wool batt<br />

– Resilient channel<br />

• 2 layers 15.9 mm (5/8�) SHEETROCK FIRECODE UL Des L541 59 RAL-TL-90-40<br />

B-60<br />

C Core Gypsum Panels<br />

– 2x10 wood joists 400 mm (16�) o.c.<br />

– 75 mm (3�) mineral wool batt<br />

– Resilient channel<br />

• 2 layers 15.9 mm (5/8�)SHEETROCK FIRECODE UL Des L541 66 59 RAL-020602<br />

<strong>SA</strong>305 B-61<br />

C Core Gypsum Panel<br />

• optional SRM-25 or SRB sound mat<br />

LEVELROCK, SRB and vinyl<br />

– 15 mm (19/32�) wood subfloor<br />

67 52 RAL-020503<br />

– 2x10 wood joist spaced 400 mm (16�) o.c.<br />

– 75 mm (3�) <strong>SA</strong>FB<br />

LEVELROCK and SRB – no flooring<br />

– Resilient channel<br />

67 53 RAL-020701<br />

• 38 mm (1-1/2�) LEVELROCK Floor Underlayment<br />

LEVELROCK, SRB and ceramic tile<br />

• 2 layer 15.9 mm (5/8�)SHEETROCK FIRECODE UL Des L511 <strong>SA</strong>305 B-62<br />

C Core Gypsum Panels<br />

– 12 mm (15/32�) T&G wood subfloor<br />

– 2x10 wood joist<br />

– Resilient channel<br />

– joints finished<br />

• optional 19.1 mm (3/4�) LEVELROCK<br />

Floor Underlayment<br />

• optional SRM-25 or SRB sound mat<br />

37 <strong>CGC</strong> <strong>Fire</strong>-<strong>Resistant</strong> <strong>Assemblies</strong><br />

58 RAL-TL-89-145<br />

Based on vinyl tile over oriented<br />

board in place of ceramic tile and<br />

cement board<br />

51 RAL-IN-89-7<br />

59 RAL-TL-89-146<br />

Based on carpet/pad over oriented<br />

strand board in place of ceramic<br />

tile and cement board<br />

60 RAL-TL-89-141<br />

62 RAL-IN-89-8<br />

69 RAL-IN-90-5<br />

59 RAL-TL-90-40<br />

Based on vinyl tile in<br />

place of carpet/pad<br />

37 RAL-IN-90-6