46<br />

<strong>AIGA</strong> 012/04<br />

Appendix D: Detergent cleaning of pipes with high pressure cleaning<br />

equipment<br />

1 Parts to be Cleaned<br />

Bent and straight pipes.<br />

Welded, brazed and soldered manifolds.<br />

Minimum internal pipe diameter:<br />

� Around 13 mm (Depending on hose and nozzle diameter).<br />

Maximum internal pipe diameter:<br />

� Around 300 mm (Depending on nozzle design and pressure.)<br />

Maximum bending angle:<br />

� 90°<br />

Minimum bending radius<br />

� 100-150 mm (Depending on pipe diameter, hose flexibility etc.)<br />

Material<br />

� Stainless steel pipes/manifolds. Some with brass connections soldered to the pipes.<br />

Maximum pipe length<br />

� Up to 30 m. Depending on hose length, number of pipe bends, pipe diameter.<br />

2 Processing of the Parts before Detergent Cleaning<br />

Stainless steel pipes exposed to different kind of treatment like bending, soldering and welding<br />

followed by pickling and pressure testing with potable water.<br />

3 Cleaning Equipment<br />

A high pressure cleaning equipment with high pressure flexible hose and pipe cleaning nozzles. (See<br />

fig 1).<br />

The backward directed jets from the nozzle pull the hose into and through the pipe while flushing the<br />

internal surface.<br />

Hot potable water or apparatus equipped with water heating facilities may be required for heavy duty<br />

cleaning.<br />

4 Cleaning<br />

The cleaning agent is applied at low pressure and ambient temperature via the hose and the nozzle.<br />

In this sequence, the hose must be transported through the pipe manually.<br />

The cleaner foam must wet the whole internal surface.<br />

The cleaner foam is left 5-10 minutes inside the pipe for dirt dissolving action. During this time period,<br />

the pipe should be rotated/turned around 2-3 times to ensure good cleaner accessibility.<br />

5 Rinsing<br />

The internal surface of the pipe is rinsed by warm high pressure clean water from the pipe cleaning<br />

nozzle. The hose is slowly transported back and forth so that all internal surfaces are in contact with