09.03.2013 Views

SEALANTS & ADHESIVES - CH Reed Inc.

SEALANTS & ADHESIVES - CH Reed Inc.

SEALANTS & ADHESIVES - CH Reed Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Automatic Dispense Valve Selection Guide<br />

Service<br />

Manual<br />

306715<br />

Description Replaces<br />

n/a<br />

Air<br />

to Close (6)<br />

Air<br />

to Open<br />

Fluid<br />

Outlet<br />

Fluid<br />

Inlet<br />

Working<br />

Pressure<br />

Part<br />

Number<br />

Valve<br />

Style<br />

tip seal gun, includes tip and<br />

needle.<br />

3/8" npt (m) 3/8" npt (m) 1/4" npsm(m) spring<br />

Stainless steel<br />

205435 3000 psi<br />

210 bar<br />

Standard<br />

Duty<br />

APPLICATORS ❚ <strong>SEALANTS</strong> AND <strong>ADHESIVES</strong> EQUIPMENT<br />

3/8" npt (m) 3/8" npt (m) 1/4" npsm(m) spring 205435 with carbide ball and seat n/a<br />

306715<br />

207440 3000 psi<br />

210 bar<br />

3/8" npt (m) 3/8" npt (m) 1/4" npsm(m) spring 205435 without tip and needle n/a<br />

306715<br />

205612 3000 psi<br />

210 bar<br />

1/4" 1/4" orifice 1/8" npt (f) 1/8" npt (f) Snuff-back valve with EPDM seals n/a<br />

n/a<br />

C27130 2400 psi<br />

165 bar<br />

12000<br />

Series<br />

1/4" 1/4" orifice 1/8" npt (f) 1/8" npt (f) Snuff-back valve with Viton seals n/a<br />

n/a<br />

C27134 2400 psi<br />

165 bar<br />

1/4" 1/4" or flange 1/8" npt (f) spring Base seal valve n/a<br />

n/a<br />

C27151 2400 psi<br />

165 bar<br />

1/4" 1/4" or flange 1/8" npt (f) 1/8" npt (f) Larger inlet n/a<br />

n/a<br />

C27340 2400 psi<br />

165 bar<br />

1/4" .093 in orifice 1/8" npt (f) spring Tip seal gun, includes nozzle n/a<br />

n/a<br />

C27142 2400 psi<br />

165 bar<br />

Notes:<br />

(1) EnDure and AutoPlus valves are used with mounting manifold, which includes all fluid and electrical connections.<br />

Mounting manifold for AutoPlus valve is 244930. EnDure valves are shipped with mounting manifold. See Graco<br />

instruction manual 309376 for details.<br />

(2) Base valve (fluid and air section) for these models is 244535<br />

(3) Base valve for these models is 244907<br />

(4) Base valve for these models is 244937<br />

(5) Maximum outlet pressure for Ultra-Lite valves is 2000 psi. Using above these pressures could cause premature<br />

needle/seat failure. See Graco manual 308876.<br />

GRACO<br />

(6) Valves marked with * in this column have redundant spring closure. If air supply is lost valve will close.<br />

101<br />