09.03.2013 Views

SEALANTS & ADHESIVES - CH Reed Inc.

SEALANTS & ADHESIVES - CH Reed Inc.

SEALANTS & ADHESIVES - CH Reed Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

4<br />

200<br />

GRACO <strong>SEALANTS</strong> AND <strong>ADHESIVES</strong> EQUIPMENT ❚ 2K EQUIPMENT<br />

Variable Ratio Hydra-Cat<br />

Mechanical Proportioner<br />

FIGURE A<br />

VARIABLE RATIO HYDRA-CAT IN<br />

MINIMUM RATIO POSITION<br />

• Air motor is connected directly to primary fluid pump<br />

• Each full stroke of air motor creates full stroke in<br />

primary fluid pump<br />

• Air motor is also connected to secondary fluid pump by<br />

lever arm, which is supported at fulcrum like a teetertotter.<br />

• In the Min-Set position, the stroke of the primary fluid<br />

pump (1) is equal to the stroke of the secondary fluid<br />

pump (2).<br />

Figure A<br />

1 = Primary Stroke 4 in. (102 mm)<br />

2 = Secondary Stroke in<br />

Minimum Ratio Position<br />

Air<br />

Motor<br />

1 2<br />

Primary<br />

Fluid Pump<br />

Fulcrum<br />

Motor<br />

Lever Arm<br />

Secondary<br />

Fluid Pump<br />

If setting is at Min-Set:<br />

• Mix ratio will be at a minimum<br />

• Pressure ratio will be at a minimum<br />

• Flow Rate will be at a maximum<br />

FIGURE B<br />

VARIABLE RATIO HYDRA-CAT IN<br />

MAXIMUM RATIO POSITION<br />

• Secondary fluid pump was moved closer to the fulcrum<br />

• In the Max-Set position, air motor and primary fluid<br />

pump still make full stroke (1), but secondary fluid pump<br />

now makes shorter stroke (3) which is less than 25% of<br />

original stroke length.<br />

• By moving the secondary fluid pump closer to or farther<br />

from the fulcrum, any ratio in the basic range can be<br />

obtained.<br />

Air<br />

Motor<br />

1<br />

Primary<br />

Fluid Pump<br />

Fulcrum<br />

Motor<br />

Lever Arm<br />

Secondary<br />

Fluid Pump<br />

If setting is at Max-Set:<br />

• Mix ratio will be at a maximum<br />

• Pressure ratio will be at a maximum<br />

• Flow Rate will be at a minimum<br />

Figure B<br />

1 = Primary Stroke<br />

4 in. (102 mm)<br />

3 = Secondary Stroke<br />

in Maximum<br />

Ratio Position

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!