Section V<br />
Paragraphs 5-40 to 5-42<br />
c. Set Time-Mark Generator output to 5 mc and<br />
adjust vertical SENSITIVITY and VERTICAL POSI-<br />
TION for a 6-cm display coinciding with top and bot-<br />
tom lines of graticule.<br />
d. Set HORIZONTAL POSITION to align left side<br />
of display with left graticule edge.<br />
e. Adjust Pattern Adj R345 for minimum barrel-<br />
ing or pin-cushioning around top, bottom, and left<br />
sides of display (see figure 5-4).<br />
f. Adjust HORIZONTAL POSITION to align right<br />
side of display with right graticule edge.<br />
g. Trim Pattern Adj R345, if necessary, for minimum<br />
barreling or pin-cushioning. Repeat steps d<br />
and e for squarest overall pattern.<br />
h. Disconnect Time-Mark Generator.<br />
5-40. HORIZONTAL AMPLIFIER.<br />
5-41. Refer to figure 5-3 for location of adjustments.<br />
5-8<br />
BARRELING<br />
5-42. SWEEP GAIN.<br />
Model <strong>175A</strong><br />
a. Locate foam-covered wire which connects sweep<br />
generator output to horizontal amplifier input (see<br />
figure 5-3).<br />
b. Disconnect wire from sweep generator printed<br />
circuit board.<br />
c. Set:<br />
HORIZONTAL DISPLAY . . . . . . . . X1<br />
d. Connect the Calibration Generator to the foam-<br />
covered wire and set output to 50 volts peak-to-peak.<br />
e. Center display and adjust X1 Gain Adj R225 for<br />
5.5 cm of horizontal deflection.<br />
f. Set:<br />
Figure 5-4. Pattern Adjustment<br />
HORIZONTAL DISPLAY . . . . . . . . XI0<br />
g. Set Calibration Generator output to 5 volts peak-<br />
to-peak.<br />
I<br />
I<br />
PI N-CUSHION ING<br />
I<br />
I<br />
<strong>175A</strong>-A-8<br />
i<br />
01526-2