<strong>Brunswick</strong> A-2 Pinsetter Modifications<br />

Switch Cluster<br />

Figure 10. <strong>Brunswick</strong> A-2 Pinsetter Switch Cluster<br />

The Switch Cluster is a metal plate containing switches and cams that are<br />

mounted on the detector and is engaged to the detector 1:1 gear. The nylon gear<br />

that drives the cam shaft turns the cams which are timed to close the switches at<br />

proper times during the pinsetter cycle. Refer to Figure 10.<br />

(1) ADJUSTABLE CAM (2) 0º SWITCH (ZERO) (3) B-2000 SWITCH (NO LONGER<br />

USED)<br />

(4) 44º/144º SWITCH ("TAKE DATA")<br />

44o /144o Switch (“Take Data”)<br />

1. This switch closes twice every pinsetter cycle. The first switch closing<br />

will cause a “take data” signal when the deck is approximately 1" (44°)<br />

above the pins if the pinsetter is on first ball.<br />

2. The second switch closing will cause a “take data” signal at 144° when<br />

the rake is approximately 10" from the no. 1 pin if the pinsetter is on<br />

second ball.<br />

3. The switch is also used during special pinsetter cycles to energize the<br />

New Pins Solenoid during the first ball foul or No Tap cycles so any<br />

standing pin(s) will be swept away.<br />

0o Switch<br />

1. The 0° switch closes once each pinsetter cycle. It is used to reset<br />

memory on the Video Processing Board and allows it to accept the ball<br />

detect signal.<br />

2. Energize the New Pins Solenoid at the end of the first ball and third ball<br />

fouls, tenth frame cycles so that the bowler will have a second ball shot.<br />