Figure 21. No Tap - <strong>Brunswick</strong> A-2<br />
No Tap Cycling<br />
When a bowler bowls a No Tap strike, the scorer console sends a signal to the<br />
VPS Processing PCB. In turn, the Processor energizes the New Pins Solenoid<br />
at 44° so the standing pins are swept away.<br />
1. Bowler delivers his first ball and the ball breaks the ball detect's light<br />
path.<br />
2. The ball causes the pinsetter to trigger. Refer to Figure 21.<br />
3. The 44° switch closes causing the new pin solenoid to switch the<br />
pinsetter to the second ball.<br />
4. The scorer displays an " N<br />
T X."<br />
5. 144° switch closes, but no action is taken.<br />
6. The pinsetter sweeps the pins and sets a new rack of pins.<br />
7. The 0° signal resets the scoring cycle allowing the VPS to accept<br />
another ball detect.<br />
(1) BALL DETECT (2) VPS STARTS SCORING PROCESS (3) PINSETTER TRIGGERS<br />
(4) NEW PINS SOLENOID SELECTS STRIKE (5) SCORER DISPLAYS NT AND X SCORED (6) SCISSORS BLOCKED<br />
(7) SWITCHES TO FIRST BALL AND SWEEPS (8) SETS A NEW RACK OF PINS (9) RESETS SCORING CYCLE<br />
STANDING PINS<br />
(10) 0° PULSE/360° (11) 44° PULSE (12) NO TAP<br />
(13) 144° PULSE (NO ACTION)<br />
Video Pinsensing System 31