23.03.2013 Views

Download - Brunswick

Download - Brunswick

Download - Brunswick

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Figure 21. No Tap - <strong>Brunswick</strong> A-2<br />

No Tap Cycling<br />

When a bowler bowls a No Tap strike, the scorer console sends a signal to the<br />

VPS Processing PCB. In turn, the Processor energizes the New Pins Solenoid<br />

at 44° so the standing pins are swept away.<br />

1. Bowler delivers his first ball and the ball breaks the ball detect's light<br />

path.<br />

2. The ball causes the pinsetter to trigger. Refer to Figure 21.<br />

3. The 44° switch closes causing the new pin solenoid to switch the<br />

pinsetter to the second ball.<br />

4. The scorer displays an " N<br />

T X."<br />

5. 144° switch closes, but no action is taken.<br />

6. The pinsetter sweeps the pins and sets a new rack of pins.<br />

7. The 0° signal resets the scoring cycle allowing the VPS to accept<br />

another ball detect.<br />

(1) BALL DETECT (2) VPS STARTS SCORING PROCESS (3) PINSETTER TRIGGERS<br />

(4) NEW PINS SOLENOID SELECTS STRIKE (5) SCORER DISPLAYS NT AND X SCORED (6) SCISSORS BLOCKED<br />

(7) SWITCHES TO FIRST BALL AND SWEEPS (8) SETS A NEW RACK OF PINS (9) RESETS SCORING CYCLE<br />

STANDING PINS<br />

(10) 0° PULSE/360° (11) 44° PULSE (12) NO TAP<br />

(13) 144° PULSE (NO ACTION)<br />

Video Pinsensing System 31