In order to make the New Pins Solenoid actuate on a foul, the following<br />
signals must occur:<br />
1. First ball.<br />
2. Foul signal.<br />
3. Ball detect.<br />
If the signals are present, the New Pins Solenoid will be energized two times<br />
during the pinsetter cycle. At 44° the New Pins Solenoid will energize causing<br />
the pinsetter to switch to second ball and sweep all standing pins. It energizes<br />
again at 0° causing the pinsetter to switch to second ball to give the bowler a<br />
full rack, second ball shot.<br />
For third ball, tenth frame, the New Pins Solenoid will fire one time at 0 o after<br />
a tenth frame spare or a “double.” This will automatically put the pinsetter in<br />
a second ball mode for the final ball of the game.<br />
For No Tap situations the New Pins Solenoid energizes at 44° causing the<br />
pinsetter to switch to second ball, sweep all pins from the pin deck, and reset<br />
to a full rack first ball for the next bowler.<br />