Figure 19. First Ball Foul - <strong>Brunswick</strong> A-2<br />
First Ball Foul<br />
On a first ball foul, the New Pins Solenoid switches the detector to second<br />
ball. On a first ball foul, when the New Pins Solenoid switches the detector to<br />
the second ball, the cycle link and crank generates a strike in the detector. It<br />
then blocks the scissors and prevents the pinsetter from picking up the<br />
standing pins.<br />
1. Bowler delivers his first ball and fouls.<br />
2. The ball breaks the ball detect's light path and triggers the pinsetter.<br />
Refer to Figure 19.<br />
3. The New Pins Solenoid switches the pinsetter to the second ball at 44 o ,<br />
selecting a strike cycle.<br />
4. The scorer displays an "F" and scores a "0."<br />
5. 144° switch closes, but no action is taken.<br />
6. The pinsetter sweeps the pins and sets a new rack of pins.<br />
7. The New Pins Solenoid switches the pinsetter to second ball when the<br />
0° switch closes.<br />
8. The 0° signal resets the scoring cycle to accept another ball detect.<br />
7. The 0° signal resets the scoring cycle allowing the VPS to accept<br />
another ball detect.<br />
(1) FOUL (2) BALL DETECT (3) PINSETTER TRIGGERS<br />
(4) VPS TAKES DATA (5) NEW PINS SOLENOID SWITCHES PINSETTER (6) SCORER DISPLAYS FOUL AND<br />
TO SECOND BALL SCORES 0<br />
(7) SCISSORS BLOCKED (8) SWEEPS STANDING PINS (9) SETS A NEW RACK OF PINS<br />
(10) NEW PINS SOLENOID SWITCHES (11) RESETS SCORING CYCLE (12) 0° PULSE/360°<br />
PINSETTER BACK TO SECOND BALL (13) 144° PULSE (NO ACTION) (14) FIRST BALL FOUL<br />
(15) PINSETTER SWITCHES BACK TO 1ST BALL (16) 44° PULSE<br />