|3. Twisted-Pair Cable<br />

Testing<br />

Verification of the transmission performance of the installed cabling system is<br />

recommended by the ANSI/TIA 568-C.2 standard. The primary field test parameters<br />

for twisted-pair cabling systems include:<br />

• Impedance or return loss<br />

• Attenuation or insertion loss<br />

• Near-end crosstalk<br />

• Power-sum crosstalk<br />

• Attenuation-to-crosstalk ratio<br />

• Far-end crosstalk<br />

• Propagation delay and delay skew<br />

• Noise.<br />

Wire mapping is the most basic and obvious test for any twisted-pair cable<br />

installation. A proper wire-mapping tester can detect any of the following faults:<br />

• Open pair<br />

• Shorted pair<br />

• Short between pairs<br />

• Reversed pairs<br />

• Crossed pairs<br />