compounds eluting from microwave-heated spaghetti, which incorporated a trap and<br />

condenser to capture volatiles.<br />

Solvent extraction is a technique used to capture higher molecular weight<br />

compounds than is possible with headspace analyses. Because water can also be<br />

co-extracted with the aroma compounds, an additional distillation step is <strong>of</strong>ten<br />

necessary. <strong>The</strong> high vacuum transfer (HVT) method is based on the concept <strong>of</strong><br />

transferring volatiles under vacuum between two vessels based on a large<br />

temperature differential (Engel et al., 1999). A specialized version <strong>of</strong> this is the<br />

solvent assisted flavor evaporation method, or SAFE. Engel et al. (1999) developed<br />

the SAFE, which in connection with solvent extraction and a high vacuum pump<br />

(5x10 -3 Pa) allows the isolation <strong>of</strong> volatiles from solvent extracts, food suspensions<br />

such as fruit pulp, matrices with a high fat content, and aqueous foods such as milk<br />

or beer. Engel et al. (1999) developed SAFE to avoid some <strong>of</strong> the drawbacks <strong>of</strong><br />

HVT, such as: condensation <strong>of</strong> aroma volatiles with higher boiling points inside<br />

transfer tubing, limitation to only diethyl ether and dichloromethane extracts due to<br />

their freezing point, blockage <strong>of</strong> samples high in fat in the stopcock <strong>of</strong> the sample<br />

funnel, as well as the fragility <strong>of</strong> the system. Using SAFE, higher boiling point<br />

alkanes as well as more <strong>of</strong> the polar odorants such as vanillin, sotolon and 3-<br />

methylbutanoic acid were isolated when compared to HVT. Furthermore, the use <strong>of</strong><br />

SAFE resulted in higher yields from fatty matrices <strong>of</strong> 50% fat, compared to high<br />

vacuum transfer (Engel et al., 1999). Solvent assisted flavor evaporation has been<br />

used in several applications, including the analysis <strong>of</strong> volatile compounds in fresh<br />

milk (Bendall, 2001).<br />