Functional characteristics<br />
Depending on the operating mode<br />
camera assignment or monitor<br />
assignment, 49 or 4 PC users can<br />
be called.<br />
Calling, speech and door release via<br />
the Software Client DC<strong>IP</strong> SC 600-... .<br />
The Software Client must be<br />
installed on every PC which receives<br />
door calls. Standard call tones for<br />
the Software Client 3-tone chime. A<br />
dedicated *.wav file can be assigned<br />
for each call tone.<br />
It is not possible to listen in to an<br />
existing call from other PC users in<br />
the network.<br />
The door is opened by the called<br />
PC user using a “virtual door<br />
release button”, the light switching<br />
function is actuated using a “virtual<br />
light button”. The door call can be<br />
muted with an optical display on the<br />
monitor.<br />
Camera assignment mode<br />
The SIM <strong>740</strong>-... is assigned to a<br />
door / camera. In this mode, the<br />
device can be assigned up to 49<br />
different call destinations, i.e. <strong>Siedle</strong><br />
Multi system addresses which<br />
correspond to the functions of 49<br />
Multi telephones. In this operating<br />
mode, a DC<strong>IP</strong> <strong>740</strong>-... is required<br />
for each door. This operating<br />
mode is advisable in systems with a<br />
small number of doors and a large<br />
number of PC users.<br />
Monitor assignment mode:<br />
Up to a maximum of 4 call<br />
destinations, i.e. <strong>Siedle</strong> Multi system<br />
addresses, can be assigned to the<br />
interface. These correspond to the<br />
functions of the 4 Multi telephones.<br />
The call destination can be dialled<br />
from every door within the <strong>Siedle</strong><br />
Multi (max. 254). This operating<br />
mode is advisable in systems with a<br />
large number of doors and a small<br />
number of PC users.<br />
Remarks<br />
a) Door release 12 V AC, use at least<br />
20 Ohm (e.g. TÖ 615-...)<br />
• 12 V AC consumers in the wiring<br />
diagram:<br />
• Door release appr. 600 mA<br />
• Light contact load in the door<br />
loudspeaker max. 24 V AC, 2 A<br />
c) Distance of the SIVS 610-... to the<br />
door station max. 200 m with<br />
J-Y(ST)Y 0.8 mm core material.<br />
Distance between the two devices<br />
SIVS 610-... and <strong>IP</strong>VS 600-... in<br />
the distributor max. 1 m. During<br />
installation, ensure that the door<br />
release is laid in a separate cable.<br />
Power supply voltage bv+/cv- of the<br />
SIVS 610 15 V DC, max. 300 mA<br />
When connecting additional devices<br />
to the Vario bus (terminals Da/Db),<br />
the Vario bus requires an additional<br />
power supply.<br />
d) ***Optionally the DCA <strong>740</strong>-01<br />
can be connected to the PBX<br />
extension of a telephone system.<br />
Active door calls can then be routed<br />
via the telephone.<br />
The functional features of the<br />
Software Client can still be used.<br />
19