02.07.2013 Views

the distillery redevelopment - Boston Redevelopment Authority

the distillery redevelopment - Boston Redevelopment Authority

the distillery redevelopment - Boston Redevelopment Authority

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

THE DISTILLERY<br />

REDEVELOPMENT<br />

516-524 East Second Street and 2 Dorchester Street<br />

<strong>Boston</strong> MA 02127<br />

Article 80 Submission<br />

21 May 2007<br />

Submitted to <strong>Boston</strong> <strong>Redevelopment</strong> <strong>Authority</strong> <strong>Boston</strong> MA<br />

Submitted by Second Street Associates LLC


THE DISTILLERY REDEVELOPMENT<br />

516-524 East Second Street / 2 Dorchester Street, <strong>Boston</strong> MA 02127<br />

Article 80 Submission 21 May 2007<br />

Submitted to <strong>Boston</strong> <strong>Redevelopment</strong> <strong>Authority</strong><br />

Submitted by Second Street Associates LLC<br />

Project Team Frederick M. Gordon Proponent<br />

Second Street Associates LLC<br />

516 East Second Street,<br />

South <strong>Boston</strong>, MA 02127<br />

617-269-8430 following page…


617-1776<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Hubert Murray Architect + Planner Architecture / Planning<br />

204 Erie Street, Cambridge, MA 02139<br />

617-354-9555<br />

The Hickory Consortium Energy Consultant<br />

Mark Kelly PE LEED AP.<br />

1 Jeefe Rd, Acton MA 01720<br />

978-895-0988<br />

The Office of David Neilson Urban Design.<br />

17 Powderhouse St., #316,<br />

South <strong>Boston</strong>, MA 02127<br />

617-268-0816<br />

Vanasse Hangen Brustlin Inc. Transportation / Infrastructure<br />

Susan Sloan Rossiter, Principal,<br />

99 High Street, <strong>Boston</strong>, 02110<br />

617-728-7777<br />

Weidlinger Associates Inc. Geotechnical / Structural<br />

Stephen Lew.PhD, PE, NIST<br />

201 Broadway, 4th Floor,<br />

Cambridge, MA 02139-1955<br />

617-374-0000<br />

Dr. Nancy Seasholes, PhD Site History<br />

1 Field Rd., Lexington,<br />

MA 02421-8014<br />

781-863-8085<br />

Apex. Environmental Soils Analysis<br />

Geoffrey May, LSP<br />

374 Congress Street.,<br />

<strong>Boston</strong>, MA Suite 508 02210<br />

617-728-0070 x 114<br />

Goulston and Storrs Legal<br />

Mat<strong>the</strong>w Kiefer LLB,<br />

400 Atlantic Avenue,<br />

<strong>Boston</strong>, MA 02110-3333<br />

0.0 Table of Contents 0-2


Executive Summary<br />

1. INTRODUCTION<br />

1.1. Project Objectives<br />

1.2. Housing and Urban Design Objectives<br />

1.3. Environmental and Energy Objectives<br />

1.4. Article 37<br />

2. PROGRAM<br />

2.1. Existing Program<br />

2.2. Proposed Development<br />

2.3. Construction Sequencing<br />

2.4. Program Summary<br />

2.5. Parking<br />

3. ZONING ANALYSIS<br />

3.1. Article 80 Large Project Review<br />

3.2. Article 37 Green Buildings<br />

3.3. Article 27P South <strong>Boston</strong> IPOD<br />

3.4. Project Dimensions<br />

3.5. Space Allocation<br />

3.6. O<strong>the</strong>r Permits<br />

4. SITE CONDITIONS<br />

4.1. Tidelands<br />

4.2. Flood Hazard<br />

4.3. Environmental Site History<br />

5. HISTORIC RESOURCES<br />

5.1. Neighborhood Historic Resources<br />

5.2. Site Land Use History<br />

6. URBAN DESIGN<br />

6.1. Site Context<br />

6.2. Site Development and Massing<br />

6.3. Space Allocation<br />

6.4. Access and Circulation<br />

7. ARCHITECTURE<br />

7.1. Architectural Expression<br />

7.2. H Street Elevation<br />

7.3. East First Street Elevation<br />

7.4. Dorchester Street Elevation<br />

7.5. East Second Street Elevation<br />

7.6. Roofscape<br />

Architectural Drawings 1 through 16<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

0.0 Table of Contents 0-3


8. LANDSCAPE ARCHITECTURE<br />

8.1. Street Landscape<br />

8.2. The Courtyard<br />

8.3. The Roof<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

9. TRANSPORTATION ACCESS PLAN COMPONENT<br />

9.1. Introduction<br />

9.1.1. Project Description<br />

9.1.2. Study Area<br />

9.1.3. Study Methodology<br />

9.1.4. Summary of Findings<br />

9.2. Existing Conditions<br />

9.2.1. Existing Roadway Conditions<br />

9.2.2. Study Area Intersections<br />

9.2.3. Existing Traffic Volumes<br />

9.2.4. Parking<br />

9.2.5. Crash History<br />

9.2.6. Pedestrian and Bicycle Conditions<br />

9.2.7. Public Transportation<br />

9.2.8. Vehicular Site Access<br />

9.2.9. Adjacent Land Uses<br />

9.3. Evaluation of Future Transportation Conditions<br />

9.3.1. No Build Condition<br />

9.3.2. 2011 Build Condition<br />

9.4. Traffic Operations Analysis<br />

9.5. Access to Parking<br />

9.5.1. Assessment of Alternatives<br />

9.5.2. Lower Level Access<br />

9.5.3. Upper Level Access<br />

9.5.4. Service Vehicles and Emergency Services<br />

9.6. Transportation Mitigation and Improvement Plan<br />

9.6.1. Project Improvements<br />

9.6.2. Transportation Demand Management<br />

9.6.3. Loading and Service Management Actions<br />

9.6.4. Construction Management<br />

9.7. Transportation Access Plan Agreement and Construction Management Plan<br />

10. INFRASTRUCTURE SYSTEMS<br />

10.1. Introduction<br />

10.1.1. Regulatory Framework<br />

10.2. Wastewater<br />

10.2.1. Existing Wastewater<br />

10.2.2. Demand / Use<br />

10.2.3. Proposed Connection<br />

10.3. Domestic Water and Fire Protection<br />

0.0 Table of Contents 0-4


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

10.3.1. Existing Water Supply System<br />

10.3.2. Proposed Connection<br />

10.4. Stormwater Management<br />

10.4.1. Existing Conditions<br />

10.4.2. Proposed Conditions<br />

10.4.3. Compliance with DEP Stormwater Management Policy<br />

10.5. Anticipated Energy Needs<br />

10.5.1. Electrical Service<br />

10.5.2. Natural Gas<br />

10.5.3. Telecommunications<br />

10.6. Protection of Utilities<br />

10.7. Sustainable Design / Energy Conservation<br />

10.8. Conclusion<br />

11. GEOTECHNICAL IMPACT<br />

11.1. Project Description<br />

11.2. Subsurface Exploration Program<br />

11.3. Subsurface Conditions<br />

11.4. Groundwater<br />

11.5. Foundation Design Recommendations<br />

11.6. Seismic Design<br />

11.7. Construction Considerations<br />

Figures and Tables<br />

12. ENVIRONMENTAL IMPACTS<br />

12.1. Article 37<br />

12.2. Wind<br />

12.3. Shadow<br />

12.4. Daylight<br />

12.5. Solar Glare<br />

12.6. Air Quality<br />

12.7. Water Quality<br />

13. CONSTRUCTION IMPACTS<br />

13.1. Traffic<br />

13.2. Air Quality<br />

13.3. Noise<br />

13.4. Rodent Control<br />

13.5. Wildlife Habitat<br />

13.6. Construction Management<br />

13.7. Monitoring<br />

14. DESIGN REVIEW<br />

14.1. Community Meetings<br />

14.2. <strong>Boston</strong> Civic Design Commission<br />

0.0 Table of Contents 0-5


EXECUTIVE SUMMARY<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Second Street Associates owns a property in South <strong>Boston</strong>, <strong>the</strong> site of a former rum<br />

<strong>distillery</strong>. The Distillery site is a 1.74 acre site bounded by East First Street, East Second<br />

Street, H Street and Dorchester Street.<br />

There are three main buildings on <strong>the</strong> site, totaling 105,667 gross square feet providing a<br />

total of 30 live-work units and 42 work-only units for artists and small manufacturers:<br />

• <strong>the</strong> former <strong>distillery</strong>, (consisting of <strong>the</strong> Distillery Building on East Second Street<br />

and <strong>the</strong> Warehouse on H Street) was built in <strong>the</strong> period 1862 - 1874, providing 30<br />

live-work and 38 work-only spaces.<br />

• a former <strong>distillery</strong> company bottling plant built in 1966 currently being used as a<br />

laydown area and warehouse by Fishbach and Moore, an electrical contractor.<br />

• a one-story masonry building, a former cooper shop built in <strong>the</strong> 1930’s, currently<br />

with three commercial tenancies.<br />

The aim of <strong>the</strong> owner is to redevelop <strong>the</strong> property, preserving <strong>the</strong> older, architecturally<br />

distinguished, Distillery Building while demolishing <strong>the</strong> o<strong>the</strong>r buildings on site. These<br />

will be replaced with 124,996 gross square feet of residential space, artists’ work and<br />

live-work units, workshops, offices, retail stores, and 123 parking spaces. The new<br />

building complex will be designed and constructed to reduce fossil fuel in <strong>the</strong><br />

construction materials used, <strong>the</strong> method of construction and day to day operation,<br />

achieving a high benchmark in terms of life cycle energy costs. The building will also<br />

seek to minimize non-energy related negative environmental impacts and to promote and<br />

sustain a healthy living environment.<br />

It is also <strong>the</strong> goal of <strong>the</strong> owner to attract to <strong>the</strong> property more artists, and small-scale<br />

entrepreneurs involved in green technology so that <strong>the</strong> place becomes a destination not<br />

only for its design and construction but also for <strong>the</strong> technologically progressive and<br />

creative community that will live and work in this part of South <strong>Boston</strong>.<br />

1.0 Executive Summary | Introduction 1-1


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The proposed development will retain 30 artists’ live-work units and 37 commercial units<br />

(losing one from <strong>the</strong> current count of 38) in <strong>the</strong> existing historic building on <strong>the</strong> eastern<br />

half of <strong>the</strong> site and add 44 new residential units, 25 new live-work units, art galleries, a<br />

café, greenhouse, and small-scale retail spaces with associated off-street parking. The<br />

development will produce all of its electricity on site using a renewable and almost<br />

carbon-neutral fuel. The waste heat from this process will carry all heat, hot water and<br />

air conditioning loads.<br />

Project Description<br />

Landowner: Second Street Associates LLC<br />

Developer: Second Street Associates LLC<br />

The proposed development involves <strong>the</strong> construction of two wings of four-storey<br />

residential and commercial accommodation over two basement stories of structured<br />

parking. In order to prepare this part of <strong>the</strong> site for <strong>the</strong> proposed development, two singlestorey<br />

industrial buildings will be demolished.<br />

The residential development on East First Street consists of 25 live-work studios totaling<br />

28,755 net square feet. Pedestrian access to <strong>the</strong>se units is from East First Street and an<br />

inner court, elevation +34’. Street access to <strong>the</strong> inner court is at <strong>the</strong> corner of East First<br />

and Dorchester Streets (elevation +16’) via elevator and stairs. There is also direct, atgrade<br />

access to <strong>the</strong> courtyard from East Second Street at elevation +32’.<br />

The 44-unit residential accommodation (58,751 net square feet) on Dorchester Street is<br />

accessible from five street level front doors leading to five stair and elevator cores<br />

serving residential units clustered around a shared atrium. The units are also accessible<br />

via stairs from <strong>the</strong> courtyard.<br />

There are two levels of parking. The lower level parking (59 spaces) is served by twoway<br />

access from H Street, extending along East First Street and Dorchester Street at<br />

elevation +16’. The upper level parking (capacity 64 spaces) is served by two-way access<br />

from Dorchester Street at elevation +25’, extending to Dorchester Street and First Street<br />

1.0 Executive Summary | Introduction 1-2


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

with a short spur adjacent to East Second Street. The upper level parking has a small<br />

truck loading area to serve <strong>the</strong> retail store on East Second Street. On H Street <strong>the</strong>re is a<br />

40-ft. truck loading dock that can serve, via dock and large elevator, all buildings in <strong>the</strong><br />

development, existing and proposed.<br />

The project is designed to be served by two 45 kw diesel generators powered by<br />

vegetable oil. The system will be grid-integrated for backup purposes, but o<strong>the</strong>rwise will<br />

draw no net electricity during each monthly billing cycle. All heating and cooling loads<br />

will be met by <strong>the</strong> waste heat from <strong>the</strong> electric generation. In addition to serving <strong>the</strong><br />

buildings, excess electrical capacity will be available to provide electrical charging for<br />

plug-in hybrid electrical vehicles.<br />

Zoning and Project Dimensions<br />

The site is located in <strong>the</strong> South <strong>Boston</strong> Interim Planning Overlay District under <strong>the</strong> terms<br />

of Article 27P of <strong>the</strong> Zoning Ordinance. Map 4 (South <strong>Boston</strong>) shows <strong>the</strong> site to be<br />

designated L, allowing a building height of 35 feet and an FAR of 2.0.<br />

The proposed building roof height is <strong>the</strong> same as <strong>the</strong> existing adjacent buildings<br />

established as +83’ above sea level. The grade varies from +16.5’ at <strong>the</strong> corner of First<br />

and Dorchester, to +32’ on East Second Street. The roof heights in <strong>the</strong> table below are<br />

established as height above mean grade for each of <strong>the</strong> four frontages on <strong>the</strong> block.<br />

Proposed Building Height above mean grade Existing Roof Height<br />

First Street 61.59’ n.a.<br />

H Street 53.47’ 60’-6”<br />

Second Street 48.32’ 52’-0”<br />

Dorchester Street 65.30’ n.a.<br />

The FAR of <strong>the</strong> new and existing buildings combined on <strong>the</strong> site is 3.05.<br />

Setbacks: <strong>the</strong> new buildings are built to <strong>the</strong> property line at Dorchester Street and East<br />

Second Street. On East First Street <strong>the</strong> building will be set back from <strong>the</strong> property line to<br />

allow a 5’-6” sidewalk. An open courtyard (26,322 sf) faces south onto East Second<br />

Street.<br />

1.0 Executive Summary | Introduction 1-3


1.0 INTRODUCTION<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Second Street Associates owns a property in South <strong>Boston</strong>, <strong>the</strong> site of a former<br />

rum <strong>distillery</strong>. The Distillery site is a 1.74 acre site bounded by East First Street,<br />

East Second Street, H Street and Dorchester Street.<br />

There are three main buildings on <strong>the</strong> site, totaling 105,667 gross square feet<br />

providing a total of 30 live-work units and 42 work-only units for artists and small<br />

manufacturers:<br />

• <strong>the</strong> former <strong>distillery</strong>, (consisting of <strong>the</strong> Distillery Building on East Second<br />

Street and <strong>the</strong> Warehouse on H Street) was built in <strong>the</strong> period 1862 - 1874,<br />

providing 30 live-work and 38 work-only spaces.<br />

• a former <strong>distillery</strong> company bottling plant built in 1966 currently being<br />

used as a laydown area and warehouse by Fishbach and Moore, an<br />

electrical contractor.<br />

• a one-story masonry building, a former cooper shop built in <strong>the</strong> 1930’s,<br />

currently with three commercial tenancies.<br />

The aim of <strong>the</strong> owner is to redevelop <strong>the</strong> property, preserving <strong>the</strong> older,<br />

architecturally distinguished, Distillery Building while demolishing <strong>the</strong> o<strong>the</strong>r<br />

buildings on site. These will be replaced with 124,996 gross square feet of<br />

residential space, artists’ work and live-work units, workshops, offices, retail<br />

stores, and 123 parking spaces. The new building complex will be designed and<br />

constructed to reduce fossil fuel in <strong>the</strong> construction materials used, <strong>the</strong> method of<br />

construction and day to day operation, achieving a high benchmark in terms of<br />

life cycle energy costs. The building will also seek to minimize non-energy<br />

related negative environmental impacts and to promote and sustain a healthy<br />

living environment.<br />

1.0 Executive Summary | Introduction 1-4


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

It is also <strong>the</strong> goal of <strong>the</strong> owner to attract to <strong>the</strong> property more artists, and smallscale<br />

entrepreneurs involved in green technology so that <strong>the</strong> place becomes a<br />

destination not only for its design and construction but also for <strong>the</strong> technologically<br />

progressive and creative community that will live and work in this part of South<br />

<strong>Boston</strong>.<br />

The proposed development will retain 30 artists’ live-work units and 37<br />

commercial units (losing one from <strong>the</strong> current count of 38) in <strong>the</strong> existing historic<br />

building on <strong>the</strong> eastern half of <strong>the</strong> site and add 44 new residential units, 25 new<br />

live-work units, art galleries, a café, greenhouse, and small-scale retail spaces<br />

with associated off-street parking. The development will produce all of its<br />

electricity on site using a renewable and almost carbon-neutral fuel. The waste<br />

heat from this process will carry all heat, hot water and air conditioning loads.<br />

1.1 Project Objectives<br />

The objectives that <strong>the</strong> proponent has set for <strong>the</strong> project is to create an energy<br />

efficient development minimizing dependency on fossil fuels and non-renewable<br />

resources and at <strong>the</strong> same time maintain and expand accommodation for <strong>the</strong> artists<br />

and creative entrepreneurs as well as providing new high quality conventional<br />

residences.<br />

In addition to specific studies of materials, design, and materials, <strong>the</strong> development<br />

team generated at <strong>the</strong> very outset of its work a prioritized schedule of values<br />

which this project is to realize. These are:<br />

1. Energy<br />

This project is a live social, political and technological experiment in <strong>the</strong><br />

economics of energy use in residential construction. The goal is to reduce<br />

dependence on outside sources of fossil fuel energy and o<strong>the</strong>rwise nonrenewable<br />

resources. These goals are to be quantified in terms of<br />

1.0 Executive Summary | Introduction 1-5


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

1.1. Embodied energy contained in materials<br />

1.2. Energy used in construction<br />

1.3. Energy in use<br />

1.4. Cycles of renewability for both materials and fuels<br />

2. Environment<br />

The project is designed to minimize its environmental footprint in terms<br />

of:<br />

2.1. The use of renewable resources<br />

2.2. The minimization of exposure to and creation of toxins and<br />

destructive residuals<br />

2.3. Minimizing damage to <strong>the</strong> surrounding environment and ecology,<br />

including air and water quality and <strong>the</strong> condition of <strong>the</strong> upper<br />

atmosphere<br />

3. Technology<br />

The technology employed in pursuit of <strong>the</strong>se objectives must be:<br />

3.1. State-of-<strong>the</strong>-Shelf - established and up-to-date<br />

3.2. Experimental – technologies may be tested and demonstrated<br />

within this residential configuration<br />

3.3. Robust and Redundant – durable, ei<strong>the</strong>r duplicative or non-critical<br />

and user-friendly<br />

3.4. Transferable – technologies and configurations should serve as a<br />

standard and be transferable to comparable projects elsewhere.<br />

1.0 Executive Summary | Introduction 1-6


4. Profitability<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

4.1. The project has to make a profit for <strong>the</strong> Owner. Considerations that<br />

may affect <strong>the</strong> degree of profit may be <strong>the</strong> terms of ownership<br />

(condominium or leased rental) which may be affected by <strong>the</strong><br />

terms of liability and <strong>the</strong> degree of test-bed experimentation<br />

required in use.<br />

4.2. The residences, studios, offices and retail locations have to be<br />

marketable.<br />

5. Comfort<br />

5.1. The design of <strong>the</strong> residences will provide visual, auditory and<br />

<strong>the</strong>rmal comfort.<br />

6. Community<br />

6.1. Within <strong>the</strong> context of profitability <strong>the</strong> project will incorporate a<br />

number of affordable units for artists, small sustainable<br />

development firms and non-profits in <strong>the</strong> field of sustainable<br />

development.<br />

6.2. Affordable units within <strong>the</strong> complex will be indistinguishable in<br />

quality from o<strong>the</strong>r accommodation. They will accommodate a full<br />

spectrum of qualifying candidates with accommodation sizes<br />

ranging from single room studios to 3-bedroom family units.<br />

6.3. It is important that this development contribute to, and enhance <strong>the</strong><br />

potential of, <strong>the</strong> community of artists already on site and to <strong>the</strong><br />

neighborhood and community of South <strong>Boston</strong>. The design process<br />

will fully involve members of <strong>the</strong>se communities.<br />

1.0 Executive Summary | Introduction 1-7


7. Health<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

6.4. The development of live-work space for artists and technological<br />

innovators will create a new questing and creative community at<br />

<strong>the</strong> cusp of an existing residential and former industrial area.<br />

7.1. The aim of <strong>the</strong> project is to promote a healthy environment during<br />

construction and in <strong>the</strong> living and working environment<br />

accommodated in <strong>the</strong> development. Healthy materials and<br />

processes as well as Indoor Air Quality will be particularly<br />

important not only as a good in itself but as an attractive marketing<br />

characteristic.<br />

7.2. Natural organic fruit and vegetables will be grown on site and sold<br />

to provide healthy produce to residents and neighbors.<br />

7.3. Issues to be address will focus on maximizing indoor air quality<br />

and <strong>the</strong> minimization of toxins in <strong>the</strong> structure and systems.<br />

7.4. The maintenance and operation of <strong>the</strong> building will adhere to<br />

protocols on <strong>the</strong> use of non-toxic cleaning agents, fertilizers,<br />

sprays, packaging etc.<br />

8. Liability<br />

9. Waste<br />

8.1. While this is an innovative project engaging financial,<br />

technological and social risk, it calls for risk management to<br />

reduce <strong>the</strong> liability of participating parties.<br />

9.1. The development should engage ‘cradle-to-cradle’ thinking in <strong>the</strong><br />

use of resources and materiel including construction waste, food<br />

waste, and production waste.<br />

1.0 Executive Summary | Introduction 1-8


10. Attractiveness<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

10.1. The residences must be attractive places to live in. This may be<br />

interpreted as aes<strong>the</strong>tically pleasing and as ethically and<br />

technologically attractive. In addition to creating an attractive<br />

architecture that reflects <strong>the</strong> values of <strong>the</strong> project and makes a<br />

positive contribution to <strong>the</strong> neighborhood, <strong>the</strong> building will capture<br />

views of <strong>the</strong> city and <strong>the</strong> neighborhood. A close relationship to<br />

natural vegetation will be important.<br />

10.2. Open space and landscaped roof areas within <strong>the</strong> project will<br />

embody principles of sustainability, incorporating areas for homegrown<br />

fruit and vegetables and employing recycled water for<br />

irrigation.<br />

11. Transportation<br />

12. Water<br />

11.1. The development will address <strong>the</strong> issues of urban transportation<br />

opening up possibilities of links to <strong>the</strong> neighborhood and city that<br />

reduce dependency on private automobiles. Options will include<br />

alternative fuels, shared ownership, alternative modes (such as<br />

buses, shuttles, taxis, battery driven scooters and bicycles) and<br />

walking.<br />

12.1. Water will be valued and managed as an increasingly scarce and<br />

valuable resource to be used and re-used. As an element<br />

fundamental to human life, water will also be expressed as part of<br />

<strong>the</strong> architecture and landscape.<br />

13. Defiance<br />

1.0 Executive Summary | Introduction 1-9


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

13.1. This project is a bold act of defiance. Reflecting <strong>the</strong> nature of<br />

many of <strong>the</strong> resident artists and innovators, <strong>the</strong> aim is to create a<br />

healthy, innovative, and attractive living and working environment<br />

in an urban neighborhood of a nor<strong>the</strong>rn city in defiance of climate,<br />

<strong>the</strong> changing economy, dependence on non-renewable resources<br />

and acceptance of <strong>the</strong> status quo.<br />

14. Demonstration<br />

14.1. The Distillery project aims to act as a demonstration and as a<br />

standard for comparable projects throughout <strong>the</strong> country. The<br />

project will employ methods that are reproducible elsewhere and<br />

will diffuse <strong>the</strong> innovations in technology, construction, project<br />

management and community involvement through documentation<br />

and publication.<br />

By <strong>the</strong>se standards <strong>the</strong> Distillery will measure its own success and will become a<br />

standard for o<strong>the</strong>rs.<br />

1.2 Housing and Urban Design Objectives<br />

The existing buildings on <strong>the</strong> Distillery site include 30 residential live-work units<br />

for artists and 42 commercial units for artists, small manufacturers and service<br />

operations. The larger of <strong>the</strong> two one-storey buildings on Dorchester Street is<br />

currently occupied by an electrical contractor who uses <strong>the</strong> space as a warehouse.<br />

This is a temporary location for <strong>the</strong> contractor, Fishbach and Moore, for <strong>the</strong>ir<br />

work on <strong>the</strong> “Big Dig;” it will soon be completed and that building will be vacant.<br />

The smaller of <strong>the</strong> two buildings, a former cooper shop, has three small-scale<br />

tenants.<br />

As proposed, <strong>the</strong> new development will consist of 25 live-work units on <strong>the</strong> East<br />

First Street frontage and 44 residential units on <strong>the</strong> Dorchester Street frontage.<br />

The new development will also include small commercial and retail spaces at<br />

1.0 Executive Summary | Introduction 1-10


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

street level. At courtyard level <strong>the</strong>re will be a café and two small galleries<br />

(included in <strong>the</strong> commercial / retail category below).<br />

Table 1-1 NET NEW UNITS<br />

Units<br />

Existing Lost Gained Total<br />

Commercial / Retail 42 -1 6 47<br />

Live-Work 30 0 25 55<br />

Residential 0 0 44 44<br />

Total 72 -1 75 146<br />

The aim of <strong>the</strong> development is to retain existing tenancies as affordable units for<br />

artists and small businesses. It is envisioned that <strong>the</strong> existing Distillery building<br />

will not be improved and will remain a relatively low-cost rental location for its<br />

artist and commercial tenants. The new development is designed to attract more<br />

of <strong>the</strong> same type of enterprise, with an emphasis on small-scale entrepreneurs<br />

engaged in ‘green technology’ so that <strong>the</strong> site will become a destination for those<br />

interested in this field.<br />

This project will be developed in accordance with <strong>the</strong> Executive Order of Mayor<br />

Thomas M. Menino dated May 16th 2006 relative to <strong>the</strong> Inclusionary<br />

Development Policy of <strong>the</strong> City of <strong>Boston</strong>. The number of affordable units in <strong>the</strong><br />

project will be not less than 15% of <strong>the</strong> total market rate units, i.e. 15% of 69 units<br />

= 10 units.<br />

The intention is to retain <strong>the</strong> residential units as rental apartments at least for <strong>the</strong><br />

first five years after completion so that any wrinkles in <strong>the</strong> new technology can be<br />

ironed out. Finishes will be kept very simple allowing residents to complete <strong>the</strong><br />

units according to <strong>the</strong>ir own taste and budgets.<br />

1.3 Environmental and Energy Objectives<br />

The proposed buildings will use a unique engineering approach to achieve<br />

reduction in energy use and environmental impact which until now has been<br />

achievable only by small-scale experimental architecture. This approach<br />

involves three main factors: building geometry, cogeneration of electricity with<br />

1.0 Executive Summary | Introduction 1-11


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

renewable fuel, and energy efficient shell and floor slabs. O<strong>the</strong>r techniques,<br />

passive solar heat gain, heliostats, daylighting, natural venting and heat recovery<br />

venting are included in our design, but play a lesser role in <strong>the</strong> energy<br />

performance. Integration of electrical cogeneration, plug-in hybrid vehicles and<br />

o<strong>the</strong>r innovative transportation initiatives also contribute to benchmark setting<br />

reductions in <strong>the</strong> total energy and environmental impact of <strong>the</strong> site.<br />

The conceptualization of <strong>the</strong> energy profile of <strong>the</strong> project was facilitated by a<br />

grant from <strong>the</strong> Massachusetts Technology Collaborative. The report, The<br />

Feasibility Study of Renewable Energy and Energy Efficiency Options for a 79unit<br />

Condominium Development in South <strong>Boston</strong> (May 2005), is available from<br />

<strong>the</strong> MTC or from <strong>the</strong> developer. This study defined <strong>the</strong> building’s energy<br />

efficient building morphology, and did a broad survey of <strong>the</strong> energy efficiency<br />

technologies which <strong>the</strong> project will implement. A second grant from MTC for<br />

$40,000, A Feasibility study for Vegetable Oil CHP, was awarded in October,<br />

2006, and is focused more specifically on establishing <strong>the</strong> feasibility of using<br />

virgin vegetable oil as an energy source for a combined heat and power system.<br />

Work under this grant commenced on Dec. 13 th , and should be completed May 1,<br />

2007.<br />

1.4 Construction<br />

In addition to complying with <strong>the</strong> pertinent regulations, it is an objective of <strong>the</strong><br />

proponent to incorporate into <strong>the</strong> construction process healthful and<br />

environmentally responsible principles insofar as this is practicable. In order to<br />

maintain as much normal use of <strong>the</strong> property as possible, <strong>the</strong> construction will be<br />

sequenced so that <strong>the</strong> vacant north sector of <strong>the</strong> lot will be developed first – <strong>the</strong><br />

live-work studios facing East First Street – to be followed by <strong>the</strong> development of<br />

<strong>the</strong> residential units on Dorchester Street.<br />

1.0 Executive Summary | Introduction 1-12


2.0 PROGRAM<br />

2.1 Existing Program<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Currently <strong>the</strong>re are three main buildings on <strong>the</strong> 1.74-acre site:<br />

• <strong>the</strong> Distillery / Warehouse, containing 30 live-work and 38 work-only<br />

units;<br />

• <strong>the</strong> Honeywell Building / former bottling plant , currently accommodating<br />

one commercial tenant using <strong>the</strong> building as light manufacturing and<br />

warehousing;<br />

• <strong>the</strong> Cooper Shop, currently accommodating 3 small-scale commercial<br />

tenants.<br />

The existing disposition of buildings on <strong>the</strong> site is shown in Figure 2-1:<br />

HONEYWELL BUILDING<br />

Figure 2-1: Existing Buildings<br />

COOPER SHOP<br />

WAREHOUSE<br />

DISTILLERY<br />

2.0 Program 2-1


The existing program is summarized in Table 2-1:<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Table 2-1 PROGRAM IN EXISTING BUILDINGS (Distillery / Warehouse / Honeywell / Cooper Shop)<br />

Program Use Gp NSF # units<br />

Residential Units (Live-Work units) R-2 42,798 30<br />

Studio non-live Work Units (Commercial) B 31,812 41<br />

Industrial / Light Manufacturing F-2 21,950 1<br />

Total Units 96,560 72<br />

Gross Area (GSF) 105,667<br />

Parking<br />

Parking available to residential and commercial units 45<br />

O<strong>the</strong>r parking rented to Fishbach and Moore 21<br />

Total Parking 66<br />

2.2 Proposed Development<br />

The aim of <strong>the</strong> owner is to redevelop <strong>the</strong> property, preserving <strong>the</strong> older Distillery<br />

building while demolishing <strong>the</strong> o<strong>the</strong>r buildings on site, replacing <strong>the</strong>m with<br />

apartments, artists’ studios and studio apartments, workshops, offices and retail<br />

stores. The overall layout is shown in Figure 2-2:<br />

Figure 2-2: Proposed Development<br />

2.0 Program 2-2


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The proposed development will retain <strong>the</strong> artists’ live-work units and commercial<br />

units in <strong>the</strong> existing historic building on <strong>the</strong> eastern half of <strong>the</strong> site and on <strong>the</strong><br />

north and west edges of <strong>the</strong> site add new residential units, new live-work units;<br />

and a mix of galleries, a café, greenhouse, and small-scale retail spaces with<br />

associated off-street parking. Where <strong>the</strong> proposed new building and <strong>the</strong> existing<br />

building join (at <strong>the</strong> corner of H Street and First) <strong>the</strong>re is a reconfiguration of livework<br />

studios on six floors (with no reduction) and <strong>the</strong> loss of one existing workonly<br />

unit (in <strong>the</strong> basement) to accommodate that junction and <strong>the</strong> vertical<br />

circulation. The net total of existing and proposed units is summarized in Table<br />

2-2:<br />

Table 2-2 EXISTING AND NEW UNITS<br />

Units<br />

Existing Lost Gained Total<br />

Commercial / Retail 42 -5 6 43<br />

Live-Work 30 0 25 55<br />

Residential 0 0 44 44<br />

Total 72 -1 75 142<br />

The residential accommodation on East First Street consists of 25 live-work<br />

studios on four floors. There is direct pedestrian access to <strong>the</strong>se units from East<br />

First Street and from <strong>the</strong> inner court, two levels up at elevation +34’. Street access<br />

to <strong>the</strong> inner court is at <strong>the</strong> corner of East First and Dorchester Streets (elevation<br />

+16’) via elevator and stairs. There is also direct, at-grade access to <strong>the</strong> court from<br />

East Second Street.<br />

The residential accommodation on Dorchester Street consists of 44 new<br />

residential units on four floors, arranged in five cores centered on stairs, elevators<br />

and an enclosed atrium. The units are also accessible via stairs from <strong>the</strong> courtyard.<br />

There are two levels of parking. The lower level parking (59 spaces) is served by<br />

two-way access from H Street, extending along East First Street and Dorchester<br />

Street at elevation +16’. The upper level parking (64 spaces) is served by two-way<br />

access from Dorchester Street at elevation +25’, extending to Dorchester Street<br />

2.0 Program 2-3


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

and First Street with a short spur adjacent to East Second Street. The upper level<br />

parking has a small truck loading area to serve <strong>the</strong> retail store on East Second<br />

Street. On H Street <strong>the</strong>re is a large truck loading dock that can serve all buildings<br />

in <strong>the</strong> development, existing and proposed.<br />

2.3 Construction Sequencing<br />

In order to maintain revenue while construction proceeds <strong>the</strong> proposed sequencing<br />

of <strong>the</strong> work will be split into two phases. Phase 1 will be built on largely vacant<br />

land demolishing only <strong>the</strong> Cooper Shop, leaving <strong>the</strong> Honeywell Building in place.<br />

Phase 1 will be completed and occupied as construction proceeds into Phase 2,<br />

entailing <strong>the</strong> demolition of <strong>the</strong> Honeywell Building to make way for <strong>the</strong><br />

residential units on Dorchester Street. This is illustrated in Figures 2-3 and 2-4.1,<br />

2.4.2, and 2.4.3 below.<br />

PHASE 2<br />

Figure 2-3: Construction Sequencing<br />

PHASE 1<br />

2.0 Program 2-4


Figure 2.4.1 Phase 1 Construction – Level 1<br />

Figure 2.4.2 Phase 1 Construction – Level 2<br />

Figure 2.4.3 Phase 1 Construction – Level 3<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

2.0 Program 2-5


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The development and disposition of new units and <strong>the</strong> net totals through Phases 1<br />

and 2 is shown in Table 2-3:<br />

Table 2-3 CONSTRUCTION SEQUENCING BY PHASE<br />

EXISTING Commercial Live/ Work Residential Total Parking<br />

Distillery / Warehouse 38 30 68<br />

Honeywell 1 1<br />

Cooper 3 3<br />

Total Occupancies 42 30 0 72<br />

Parking Surface 66<br />

Parking Structured 0<br />

Parking Total 66<br />

PHASE ONE Commercial Live/ Work Residential Total Parking<br />

Distillery / Warehouse 37 30 67<br />

Honeywell 1 1<br />

Phase One Building 3 25 12 40<br />

Total Occupancies 41 55 12 108<br />

Parking Surface 24<br />

Parking Structured 45<br />

Parking Total 69<br />

PHASE TWO Commercial Live/ Work Residential Total Parking<br />

Distillery / Warehouse 37 30 67<br />

Phase One Building 3 25 12 40<br />

Phase Two Building 3 32 35<br />

Total Occupancies 43 55 44 142<br />

Parking Surface 0<br />

Parking Structured 123<br />

Parking Total 123<br />

2.4 Program Summary<br />

A summary of <strong>the</strong> program (for new construction) by Use Group in total and by<br />

phase is shown in Table 2-4 on <strong>the</strong> following pages.<br />

2.0 Program 2-6


Table 2-4 PROPOSED PROGRAM BY USE GROUP AND PHASE<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

PHASE 1 PHASE 2 TOTAL<br />

Commercial Unit Use Gp nsf units nsf units nsf units<br />

COM 1.1 - store at Dorchester L1 M 472 1 626 626 1<br />

COM 3.1 - Dorchester and Second L3 M - - 1,500 1 1,500 1<br />

COM 3.2 - café L3 A-3 1,584 1 1,584 1<br />

COM 4.1 - greenhouse L4 B - - 1,319 1 1,319 1<br />

GAL 2.1 - Gallery (in courtyard) L2 A-3 - - 1,324 1 1,324 1<br />

GAL 3.1 - Gallery L3 A-3 868 1 868 1<br />

Total 2,924 3 4,769 3 7,221 6<br />

PHASE 1 PHASE 2 TOTAL<br />

Residential - Live Work Studios Unit Use Gp nsf units nsf units nsf units<br />

LWS 3.01 R-2 1,014 1 - - 1,014 1<br />

LWS 3.02 R-2 1,006 1 - - 1,006 1<br />

LWS 3.03 R-2 1,030 1 - - 1,030 1<br />

LWS 3.04 R-2 1,249 1 - - 1,249 1<br />

LWS 4.01 R-2 1,121 1 - - 1,121 1<br />

LWS 4.02 R-2 1,445 1 - - 1,445 1<br />

LWS 4.03 R-2 1,127 1 - - 1,127 1<br />

LWS 4.04 R-2 1,050 1 - - 1,050 1<br />

LWS 4.05 R-2 1,160 1 - - 1,160 1<br />

LWS 4.06 R-2 1,000 1 - - 1,000 1<br />

LWS 4.07 R-2 1,249 1 - - 1,249 1<br />

LWS 5.01 R-2 1,121 1 - - 1,121 1<br />

LWS 5.02 R-2 1,445 1 - - 1,445 1<br />

LWS 5.03 R-2 1,127 1 - - 1,127 1<br />

LWS 5.04 R-2 1,050 1 - - 1,050 1<br />

LWS 5.05 R-2 1,160 1 - - 1,160 1<br />

LWS 5.06 R-2 1,000 1 - - 1,000 1<br />

LWS 5.07 R-2 1,249 1 - - 1,249 1<br />

LWS 6.01 R-2 1,121 1 - - 1,121 1<br />

LWS 6.02 R-2 1,445 1 - - 1,445 1<br />

LWS 6.03 R-2 1,127 1 - - 1,127 1<br />

LWS 6.04 R-2 1,050 1 - - 1,050 1<br />

LWS 6.05 R-2 1,160 1 - - 1,160 1<br />

LWS 6.06 R-2 1,000 1 - - 1,000 1<br />

LWS 6.07 R-2 1,249 1 - - 1,249 1<br />

- -<br />

Total 28,755 25 - - 28,755 25<br />

2.0 Program 2-7


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

PHASE 1 PHASE 2 TOTAL<br />

Residential Units Unit Use Gp nsf units nsf units nsf units<br />

APT 3.01 R-2 - - 1,455 1 1,455 1<br />

APT 3.02 R-2 - - 1,446 1 1,446 1<br />

APT 3.03 R-2 - - 1,446 1 1,446 1<br />

APT 3.04 R-2 - - 1,446 1 1,446 1<br />

APT 3.05 R-2 - - 1,446 1 1,446 1<br />

APT 3.06 R-2 - - 1,446 1 1,446 1<br />

APT 3.07 R-2 - - 1,446 1 1,446 1<br />

APT 3.08 R-2 - - 1,446 1 1,446 1<br />

APT 3.09 R-2 1,446 1 - - 1,446 1<br />

APT 3.10 R-2 748 1 - - 748 1<br />

APT 3.11 R-2 700 1 - - 700 1<br />

APT 4.01 R-2 - - 1,464 1 1,464 1<br />

APT 4.02 R-2 - - 1,481 1 1,481 1<br />

APT 4.03 R-2 - - 1,481 1 1,481 1<br />

APT 4.04 R-2 - - 1,481 1 1,481 1<br />

APT 4.05 R-2 - - 1,481 1 1,481 1<br />

APT 4.06 R-2 - - 1,481 1 1,481 1<br />

APT 4.07 R-2 - - 1,481 1 1,481 1<br />

APT 4.08 R-2 - - 1,481 1 1,481 1<br />

APT 4.09 R-2 1,481 1 - - 1,481 1<br />

APT 4.10 R-2 748 1 - - 748 1<br />

APT 4.11 R-2 700 1 - - 700 1<br />

APT 5.01 R-2 - - 1,464 1 1,464 1<br />

APT 5.02 R-2 - - 1,481 1 1,481 1<br />

APT 5.03 R-2 - - 1,481 1 1,481 1<br />

APT 5.04 R-2 - - 1,481 1 1,481 1<br />

APT 5.05 R-2 - - 1,481 1 1,481 1<br />

APT 5.06 R-2 - - 1,481 1 1,481 1<br />

APT 5.07 R-2 - - 1,481 1 1,481 1<br />

APT 5.08 R-2 - - 1,481 1 1,481 1<br />

APT 5.09 R-2 1,481 1 - - 1,481 1<br />

APT 5.10 R-2 748 1 - - 748 1<br />

APT 5.11 R-2 700 1 - - 700 1<br />

APT 6.01 R-2 - - 1,464 1 1,464 1<br />

APT 6.02 R-2 - - 1,481 1 1,481 1<br />

APT 6.03 R-2 - - 1,481 1 1,481 1<br />

APT 6.04 R-2 - - 1,481 1 1,481 1<br />

APT 6.05 R-2 - - 1,481 1 1,481 1<br />

APT 6.06 R-2 - - 1,481 1 1,481 1<br />

APT 6.07 R-2 - - 1,481 1 1,481 1<br />

APT 6.08 R-2 - - 1,481 1 1,481 1<br />

APT 6.09 R-2 1,481 1 - - 1,481 1<br />

APT 6.10 R-2 748 1 - - 748 1<br />

APT 6.11 R-2 700 1 - - 700 1<br />

Total 11,681 12 47,070 32 58,751 44<br />

2.0 Program 2-8


2.5 Parking<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

A summary of <strong>the</strong> parking program by phase is shown in Table 2-5. Fur<strong>the</strong>r<br />

analysis is provided in Chapter 9: Transportation Access Plan.<br />

Table 2-5 PARKING<br />

PHASE 1 PHASE 2 - TOTAL<br />

Use Gp nsf spaces nsf spaces<br />

Lower Parking (Level 1) S-2 9,348 23 21,955 59<br />

Upper Parking (Level 2) S-2 8,116 22 25,056 64<br />

Surface parking (phase 1 only) N.A. 24 -<br />

Total 17,464 69 47,011 123<br />

2.0 Program 2-9


3.0 ZONING ANALYSIS<br />

3.1 Article 80<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The proposed project amounts to 124,996 gross square feet of new construction<br />

(excluding associated garage space) and <strong>the</strong>refore qualifies for consideration as a<br />

Large Project under <strong>the</strong> terms of Article 80B.<br />

3.2 Article 37<br />

Article 37, Green Buildings, adopted into Article 80 on January 10 th 2007, is<br />

addressed in this proposal in Chapter 12 Environmental Impacts, Section 12.1 and<br />

Appendices 12-1 and 12-2.<br />

3.3 South <strong>Boston</strong> IPOD Article 27P<br />

The site is located in <strong>the</strong> South <strong>Boston</strong> Interim Planning Overlay District under<br />

<strong>the</strong> terms of Article 27P of <strong>the</strong> Zoning Ordinance. Map 4 (South <strong>Boston</strong>) shows<br />

<strong>the</strong> site to be designated L, allowing a building height of 35 feet and an FAR of<br />

2.0. Tables 3-1 through 3-3 provide basic dimensions of <strong>the</strong> proposed<br />

development.<br />

3.4 Project Dimensions<br />

Project dimensions are tabulated in Tables 3-1 through 3-4 below.<br />

Building Heights: The proposed building roof height is <strong>the</strong> same as <strong>the</strong> existing<br />

adjacent buildings. The grade varies from +16.5’ at <strong>the</strong> corner of First and<br />

Dorchester, to +32’ on East Second Street as shown in Figure 3-1. The roof<br />

heights in Table 3-1 below are established as height above mean grade for each of<br />

<strong>the</strong> four frontages on <strong>the</strong> block.<br />

3.0 Zoning 3-1


+ 16.5’<br />

Table 3-1 BUILDING HEIGHTS – above mean<br />

grade<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Proposed Building Heights Existing Roof Height<br />

First Street 61.59’ n.a.<br />

H Street 53.47’ 60’-6”<br />

Second Street 48.32’ 52’-0”<br />

Dorchester Street 65.30’ n.a.<br />

Setbacks and Sidewalks: <strong>the</strong> new buildings are built to <strong>the</strong> property line at<br />

Dorchester Street, H Street and East Second Street. On East First Street <strong>the</strong><br />

building will be set back from <strong>the</strong> property line to allow for a 5’-6” sidewalk<br />

(currently 4’-0”) to be compatible with <strong>the</strong> new sidewalk built on <strong>the</strong> adjacent<br />

block. An open courtyard, part of <strong>the</strong> property but publicly visible and accessible,<br />

faces south on East Second Street.<br />

Table 3-2 PROJECT DIMENSIONS<br />

Height Stories Frontage Setback Sidewalk<br />

proposed<br />

Sidewalk<br />

existing<br />

East First Street 61.59’ 2 parking + 4 187’-0” 0’-0” 5’-6” 4’-0”<br />

H Street 53.47’ 2 parking + 4 56’-0” 0’-0” 8’-0” 8’-0”<br />

Second Street 48.32’ 2 parking + 4<br />

1 parking<br />

93’-6”<br />

110-0”<br />

+ 19.5’<br />

+ 29.5’ +32’<br />

+ 30.5’<br />

Figure 3-1<br />

Spot Grade Elevations<br />

0’-0” 8’-6” 8’-6"<br />

Dorchester Street 65.30’ 2 parking + 4 316’-6” 0’-0” 8’-5” to 11’-4” 8’-5” to 11’-4”<br />

3.0 Zoning 3-2


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Floor Area Ratio: <strong>the</strong> FAR is shown both as a function of <strong>the</strong> proposed new building<br />

in relation to <strong>the</strong> available developable area on <strong>the</strong> lot; and as a function of <strong>the</strong><br />

proposed new development and <strong>the</strong> existing property in relation to <strong>the</strong> total lot<br />

area.<br />

Table 3-3 FLOOR AREA RATIO<br />

1.0 LOT AREA<br />

1.1 Total Lot Area 75,618 S.F.<br />

1.2 Distillery & Boiler House (footprint) 21,205 S.F.<br />

1.3 Total developable lot area (courtyard and one-storey buildings) 54,413 S.F.<br />

2.0 GROSS FLOOR AREA (GFA)<br />

2.1 Parking LEVEL 1 3,949 S.F.<br />

2.2 Parking LEVEL 2 3,954 S.F.<br />

2.3 Residential LEVEL 3 31,421 S.F.<br />

2.4 Residential LEVEL 4 28,830 S.F.<br />

2.5 Residential LEVEL 5 28,421 S.F.<br />

2.6 Residential LEVEL 6 28,421 S.F.<br />

2.7 Total Proposed GFA 124,996 S.F.<br />

2.8 Total Existing GFA 105,667 S.F.<br />

2.9 Total GFA (existing and proposed) 230,663 S.F.<br />

3.0 FLOOR AREA RATIO (FAR)<br />

3.1 Proposed GFA / Total Developable Lot Area (line 2.7 / line 1.3 ) 2.30<br />

3.2 Total GFA / Total Lot Area (line 2.9 / line 1.1 ) 3.05<br />

4.0 PARKING SPACES<br />

4.1 Level 1 Parking 59<br />

4.2 Level 2 Parking 64<br />

4.3 Total Parking spaces 123<br />

3.0 Zoning 3-3


3.5 Space Allocation<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The space use and parking program is summarized in Chapter 2 and Tables 2-1<br />

through 2-5. The allocation of space is shown on <strong>the</strong> architectural plans in<br />

Chapter 7 and summarized in Table 3-4 below:<br />

Table 3-4 SPACE ALLOCATION<br />

Stories Residential Commercial O<strong>the</strong>r<br />

East First Street 2 parking + 4 25 Live<br />

Work Units<br />

on four<br />

stories<br />

None Main pedestrian access at Level 1<br />

to residences and café / gallery on<br />

Level 3<br />

H Street 2 parking + 4 None None Access to Level 1 Parking.<br />

Truck Loading<br />

Pedestrian access<br />

Second Street 2 parking + 4<br />

1 parking<br />

Dorchester Street 2 parking + 4 44<br />

Residential<br />

Units on<br />

four stories<br />

3.6 O<strong>the</strong>r Permits<br />

None Retail outlet<br />

at street level.<br />

Greenhouse<br />

above.<br />

Emergency and delivery access to<br />

courtyard.<br />

Access to residences, galleries<br />

and cafe<br />

None 5 pedestrian access points to<br />

residential units. Vehicle access to<br />

Level 2 parking. Light truck service<br />

access.<br />

Permits that may be anticipated for this project are as follows:<br />

BOSTON <strong>Boston</strong> Landmarks Commission Review Demolition Delay<br />

<strong>Boston</strong> Water and Sewer Commission Site Plan Review<br />

<strong>Boston</strong> Water and Sewer Commission General Service Application<br />

Public Improvement Commission Specific Repairs<br />

<strong>Boston</strong> Transportation Department Construction Management Plan<br />

<strong>Boston</strong> Transportation Department Transportation Access Plan Agreement<br />

Inspectional Services Department Building Permit(s)<br />

STATE Massachusetts Historical Commission Finding of No Adverse Impact<br />

Department of Environmental Protection Sewer Connection Permit<br />

Department of Environmental Protection Notice of Demolition / Construction<br />

FEDERAL Federal Aviation Administration Notice of Hazard to Air Navigation<br />

EPA / NPDES Notice of Intent for Construction - Stormwater<br />

3.0 Zoning 3-4


4.0 SITE CONDITIONS<br />

4.1 Tidelands<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

MGL Chapter 91 and <strong>the</strong> Waterways Regulations Act 310 CMR 9.0 do not apply<br />

to <strong>the</strong> Distillery development site under any of <strong>the</strong> four stipulated criteria:<br />

1. Flowed Tidelands: <strong>the</strong> entire site is on <strong>the</strong> landward side of <strong>the</strong> Mean High<br />

Water (MHW) shoreline.<br />

2. Filled Tidelands: <strong>the</strong> historic Mean High Water ran through <strong>the</strong> middle of<br />

<strong>the</strong> site which has been gradually filled over <strong>the</strong> course of <strong>the</strong> last century<br />

and a half (see Chapter 5.0). The site is separated from <strong>the</strong> existing MHW<br />

by East First Street. In addition <strong>the</strong> closest point of <strong>the</strong> site to <strong>the</strong> existing<br />

MHW is 449 feet, which is outside <strong>the</strong> prescribed limit of 250 feet. These<br />

two factors render <strong>the</strong> site a ‘landlocked tideland’ beyond <strong>the</strong> jurisdiction<br />

of Chapter 91.<br />

3. The site does not conform with <strong>the</strong> definition of a great pond, and<br />

4. The site is not situated on a non-tidal river or stream.<br />

For <strong>the</strong>se reasons it is construed that MGL Chapter 91 does not apply. See Figure<br />

4-1 on <strong>the</strong> next page.<br />

4.2 Flood Hazard<br />

According to <strong>the</strong> FEMA Flood Insurance map (Figure 4-2), <strong>the</strong> site is in Zone C,<br />

i.e. outside <strong>the</strong> 100-year and 500-year flood zones. In addition, it is to be noted<br />

that while <strong>the</strong> lowest point of <strong>the</strong> site is at datum 116.5 (MHW = 100.0) <strong>the</strong><br />

proposed building is designed so that <strong>the</strong> lowest residential floor is at datum 135,<br />

i.e. 18.5’ higher than that lowest point. Lower levels of <strong>the</strong> construction are<br />

devoted principally to parking.<br />

4.0 Site Conditions 4-1


Figure 4-1 Tidelands<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

449 FEET<br />

Figure 4-2 FEMA Flood Insurance Rate Map, Rev. November 1990<br />

4.0 Site Conditions 4-2


4.3 Environmental Site History<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The property is located in a commercial/residential area of South <strong>Boston</strong>. The<br />

property and surrounding properties have had industrial/commercial uses for well<br />

over 100 years. The neighborhood, including portions of <strong>the</strong> property, were part<br />

of a manufactured gas plant that operated from <strong>the</strong> 1890’s to <strong>the</strong> 1930’s. A<br />

shipping channel also occupied <strong>the</strong> lower portion of <strong>the</strong> property along First<br />

Street.<br />

The property has three Release Tracking Numbers (RTN) associated with it. The<br />

response actions to <strong>the</strong> releases have been conducted under <strong>the</strong> Massachusetts<br />

Contingency Plan (310 CMR 40.0000).<br />

RTN 3 – 11965<br />

This petroleum release is associated with <strong>the</strong> former No.6 fuel oil tanks. In<br />

October 1995, a 9,000 gallon underground ground storage tank was removed from<br />

<strong>the</strong> property. During a Phase I assessment, elevated levels of total petroleum<br />

hydrocarbons were detected above reportable concentrations. A Phase II<br />

Comprehensive Site assessment was conducted. A Release Abatement Measure<br />

consisting of bioremediation was also undertaken to reduce <strong>the</strong> levels of<br />

petroleum contamination in <strong>the</strong> soil. A Method III Risk assessment confirmed that<br />

<strong>the</strong> petroleum contamination was low enough to conclude that a Condition of No<br />

Significant Risk had been obtained at <strong>the</strong> site. An Activity and Use Limitation<br />

was submitted that provided notice on <strong>the</strong> deed that soils below 9 feet from grade<br />

were to be left undisturbed unless proper oversight was obtained by a Licensed<br />

Site Professional. A Response Action Completion Report was prepared for RTN<br />

3-11965 and submitted to <strong>the</strong> Massachusetts Department of Environmental<br />

Protection in February, 1999.<br />

RTN 3 – 18069<br />

During <strong>the</strong> subsurface investigation conducted to assess <strong>the</strong> petroleum<br />

contamination as described above, elevated levels of polyaromatic hydrocarbons<br />

4.0 Site Conditions 4-3


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

(PAHs) were encountered in <strong>the</strong> soil from a boring located along First Street<br />

far<strong>the</strong>st from <strong>the</strong> former underground tank. The PAHs were attributed to past<br />

releases of coal tar from <strong>the</strong> former coal gasification facility. A Downgradient<br />

Property Status (DPS) Opinion was submitted to <strong>the</strong> DEP. The DPS was audited<br />

by <strong>the</strong> DEP and an addendum to <strong>the</strong> DPS was submitted in November, 2000. This<br />

RTN currently has DPS status for <strong>the</strong> coal tar contamination detected in soils<br />

along First Street.<br />

RTN 3 – 24537<br />

As part of <strong>the</strong> preparations for <strong>the</strong> proposed construction activities on <strong>the</strong><br />

property, <strong>the</strong> physical conditions of <strong>the</strong> existing monitoring wells associated with<br />

<strong>the</strong> above RTN (3-18069) were assessed. A total of 12 inches of dense nonaqueous<br />

phase liquid (DNAPL) was measured for <strong>the</strong> first time in <strong>the</strong> existing<br />

well near First Street. This boring had been <strong>the</strong> focus previous response action<br />

activities under RTN 3-18069. The presence of DNAPL in <strong>the</strong> groundwater<br />

constituted a new reporting condition. The DNAPL was reported to <strong>the</strong> DEP in<br />

December 2004. Immediate Response Actions (IRA) was conducted and<br />

consisted of assessment and monitoring of <strong>the</strong> DNAPL over a period of one year.<br />

DNAPL was not detected in o<strong>the</strong>r monitoring wells located in <strong>the</strong> immediate area.<br />

The site was tier classified as a Tier II site in December of 2005. An Immediate<br />

Response Action Completion report was also submitted at that time indicating<br />

that <strong>the</strong> DNAPL had been removed and had not returned during <strong>the</strong> one-year<br />

monitoring period. The site is currently under going Phase II Comprehensive Site<br />

assessment to evaluate <strong>the</strong> extent of <strong>the</strong> coal tar contamination along First Street.<br />

4.0 Site Conditions 4-4


5.0 HISTORIC RESOURCES<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

5.1 Neighborhood Historic Resources<br />

On <strong>the</strong> streets immediately abutting <strong>the</strong> Distillery site <strong>the</strong>re are no buildings of<br />

historic interest listed by <strong>the</strong> Massachusetts Historical Commission (MHC). The<br />

map at <strong>the</strong> end of this chapter (Figure 5-1) shows buildings listed by <strong>the</strong> MHC<br />

within a quarter mile radius of <strong>the</strong> site 1 . None of <strong>the</strong>se buildings is likely to be<br />

affected by <strong>the</strong> development.<br />

The Distillery buildings <strong>the</strong>mselves and <strong>the</strong> site in particular, are of historic<br />

interest although not listed by <strong>the</strong> MHC. The following account gives a history of<br />

<strong>the</strong> development of <strong>the</strong> site and buildings since 1847. During site excavation a<br />

photographic record will be kept of any major artifacts unear<strong>the</strong>d. Should any<br />

large pieces of granite be discovered <strong>the</strong>y will ei<strong>the</strong>r be used on site in a visible<br />

way as part of <strong>the</strong> historical interpretation of <strong>the</strong> site, or <strong>the</strong>y will be reserved for<br />

use on parts of <strong>the</strong> seawall elsewhere in <strong>the</strong> city.<br />

5.2 Site Land Use History<br />

The parcel owned by Second Street Associates LLC (SSA) at 516 E. Second St.,<br />

South <strong>Boston</strong>, is bounded by East Second, Dorchester, East First, and H Streets. A<br />

detail from an 1847 chart of <strong>Boston</strong> Harbor, surveyed by <strong>the</strong> U. S. Coast Survey<br />

and known for its accuracy, shows that this area was once on <strong>the</strong> north shore of<br />

South <strong>Boston</strong> - <strong>the</strong> south part of <strong>the</strong> present parcel is original uplands and <strong>the</strong><br />

north part once tidal flats (Figure 5-2). The chart also shows that in 1847 <strong>the</strong>re<br />

was, on what is now SSA land, a small L-shaped building on Dorchester Street<br />

and a small wharf extending out into <strong>the</strong> flats at <strong>the</strong> end of <strong>the</strong> street (Figure 5-2).<br />

1 Data compiled from <strong>the</strong> following:<br />

http://mhc-macris.net/VMWeb.asp?Page=towns.asp<br />

http://www.cityofboston.gov/assessing/search/<br />

http://www.cityofboston.gov/bra/pdf/maps/southboston.pdf<br />

5.0 Historic Resources 5-1


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 5-2 US Coast Survey: Plan of Inner Harbor of <strong>Boston</strong>, 1847<br />

The land that became <strong>the</strong> SSA parcel had been owned in <strong>the</strong> early nineteenth<br />

century by <strong>the</strong> South <strong>Boston</strong> Association, a corporation formed in 1805 to<br />

develop South <strong>Boston</strong> as a speculative venture. The future SSA area north of East<br />

Second between Dorchester and H Streets apparently became <strong>the</strong> property of<br />

Jonathan Mason, a member of <strong>the</strong> association, for after Mason died in 1831 this<br />

land was included in an 1836 partition of his estate. A plan of this partition, dated<br />

April 9, 1836, shows that <strong>the</strong> SSA parcel is comprised of Lots No. 47-52 in<br />

Mason's estate (Figure 5-3). The 1836 plan also shows that <strong>the</strong> north part of <strong>the</strong><br />

present SSA parcel was to become a public dock ("dock" meaning water into<br />

which ships sailed, not structures at which <strong>the</strong>y moored) and suggests that Lots<br />

47-50 had already been filled to <strong>the</strong> edge of <strong>the</strong> dock (Figure 5-3). The later 1847<br />

plan, however, shows no such dock (Figure 5-2). The explanation is probably that<br />

<strong>the</strong> dock was mandated in 1836 but <strong>the</strong> area surrounding it had not yet been filled.<br />

5.0 Historic Resources 5-2


Figure 5-3 Wadsworth survey, 1836<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Lots 47 and 48 were purchased in 1862 by Henry Sou<strong>the</strong>r. By this time <strong>the</strong> lots<br />

had definitely been filled out to <strong>the</strong> dock, for <strong>the</strong> deeds of sale cite <strong>the</strong> dock as<br />

<strong>the</strong>ir northwestern boundary. 2 It was probably Sou<strong>the</strong>r who built <strong>the</strong> existing fourand-a-half<br />

story brick brewery on E. Second Street and adjoining six-story brick<br />

malt house on H Street. These buildings were constructed sometime between<br />

1862 and 1874, for <strong>the</strong>re were no buildings on Lots 47 and 48, where <strong>the</strong><br />

buildings are located (Figures 5-3 and 5-4), when Sou<strong>the</strong>r acquired <strong>the</strong>se lots in<br />

1862 but buildings are shown in this location in an 1874 atlas. 3 Also, <strong>the</strong><br />

architecture of <strong>the</strong> buildings, with a panel-brick detail at <strong>the</strong> cornice and<br />

segmental-arch window heads, is consistent with a late 1860s/early 1870s<br />

construction date. And in 1870 when Sou<strong>the</strong>r bought <strong>the</strong> adjoining Lot 49 (Figure<br />

5-3), he is described as a "brewer.” 4<br />

2 Deeds, Suffolk [County, Massachusetts) Registry of Deeds, Edward W. Brooke Courthouse, <strong>Boston</strong>,<br />

Mass., 814: 81, 34 (hereafter cited as S.D.).<br />

3 G.M. Hopkins, Atlas of <strong>the</strong> County of Suffolk, Massachusetts. Volume 3rd including South <strong>Boston</strong> and<br />

Dorchester (Philadelphia: G.M. Hopkins & Co., 1874), Plate C. 3 S.D. 1021: 111. 4 S.D. 1874: 83.<br />

4 S.D. 1021: 111.<br />

5.0 Historic Resources 5-3


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 5-4 1888 Sanborn Insurance Atlas, Plate 113<br />

By 1883, a prospectus for <strong>the</strong> brewery on East Second St. indicates that, although<br />

it was still owned by Sou<strong>the</strong>r, it was operated by Jones, Cook and Company under<br />

<strong>the</strong> name Bay State Brewery & Malt House (Figure 5-5a). The buildings shown<br />

on <strong>the</strong> plan accompanying <strong>the</strong> prospectus (Figure 5-5b) are also shown on an<br />

1888 Sanborn atlas map of <strong>the</strong> property (Figure 5-4). The prospectus had<br />

presumably been prepared with <strong>the</strong> intention of selling <strong>the</strong> property, and in 1889<br />

Sou<strong>the</strong>r did sell it-to Frank Jones, James P. Cook, and Charles A. Sinclair of <strong>the</strong><br />

Bay State Brewery. 5 Five months later, however, Jones, Cook, and Sinclair sold<br />

<strong>the</strong> property to Frederic Jessup Stimson, Louis Curtis, and John M. Graham. The<br />

deed included a 99-year lease to <strong>the</strong> Frank Jones Brewing Company, 6 which<br />

continued to operate a brewery on <strong>the</strong> site.<br />

5 S.D. 1874: 83<br />

6 S.D. 1877: 145; 3095: 353.<br />

5.0 Historic Resources 5-4


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 5-5a 1883 Prospectus<br />

Figure 5-5b 1883 Prospectus, Plan<br />

5.0 Historic Resources 5-5


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 5-6 1899 Sanborn Insurance Atlas, Plates 27, 28<br />

Meanwhile, <strong>the</strong> property on <strong>the</strong> west side of <strong>the</strong> dock had been acquired in <strong>the</strong> late<br />

1850s and early 60s by <strong>the</strong> South <strong>Boston</strong> Gas Light Company. The company<br />

undoubtedly produced coal gas on this site, for both <strong>the</strong> 1888 and 1899 Sanborn<br />

atlases show coal sheds on <strong>the</strong> wharf portion of <strong>the</strong> property and retorts closer to<br />

West First Street (Figures 5-4 and 5-6). The coal gas was presumably stored in a<br />

gas holder located on <strong>the</strong> western part of what is now <strong>the</strong> SSA parcel (Figures 5-<br />

4, 5-5b and 5-6). In 1905 all <strong>Boston</strong> gas companies consolidated as <strong>the</strong> <strong>Boston</strong><br />

Consolidated Gas Company. In June 1905, for example, <strong>the</strong> consolidated gas<br />

company acquired al1 <strong>the</strong> property of <strong>the</strong> former South <strong>Boston</strong> Gas Light<br />

Company. 7 <strong>Boston</strong> Consolidated Gas apparently soon stopped producing coal gas<br />

on <strong>the</strong> W. First Street site, for in 1906 it sold most of <strong>the</strong> property to Lumsden and<br />

Van Stone Company, which operated a machine shop and foundry (Figure 5-7). 8<br />

7 S.D. 3049: 237.<br />

8 S.D. 3174: 356, 359.<br />

5.0 Historic Resources 5-6


Figure 5-7 1923 Sanborn Insurance Atlas<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The gas company did, however, retain <strong>the</strong> parcel at <strong>the</strong> comer of West First and<br />

Dorchester Streets for ano<strong>the</strong>r 15 years, selling it in 1921 to Windram<br />

Manufacturing Company, which produced treated cloth (Figure 5-7). 9 The gas<br />

company also maintained <strong>the</strong> gas holder at <strong>the</strong> comer or E. Second and Dorchester<br />

Streets until at least 1923 (Figures 5-7 and 5-8), selling <strong>the</strong> site, with no mention<br />

of a gasholder on it, in 1930. 10<br />

9 S.D. 4278: 530.<br />

10 S.D. 5229: 289.<br />

5.0 Historic Resources 5-7


Figure 5-8 1947 Sanborn Insurance Atlas<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Changes also occurred on <strong>the</strong> SSA parcel. In 1905, Stimson, Curtis, and Graham<br />

sold <strong>the</strong> brewery property on <strong>the</strong> eastern part of <strong>the</strong> present SSA parcel to Frederic<br />

L. Felton of Newton. 11 The brewery relinquished its lease 12 and in 1906, <strong>the</strong> same<br />

year that <strong>Boston</strong> Consolidated Gas sold most of <strong>the</strong> former South <strong>Boston</strong> Gas<br />

Light property to Lumsden and Van Stone (see above), Felton sold his property to<br />

Felton & Son, Inc. 13 The former brewery <strong>the</strong>n became a rum <strong>distillery</strong> (Figure 5-<br />

7).<br />

In 1914 <strong>the</strong> city decided to extend E. First Street westward across <strong>the</strong> dock and<br />

across <strong>the</strong> former South <strong>Boston</strong> Gas, New England Felt Roofing, and Jarvis<br />

Wharf properties to join with W. First Street (see Figures 5-6 and 5-7). 14 The<br />

11<br />

S.D. 3095: 353.<br />

12<br />

S.D. 3095: 355.<br />

13<br />

S.D. 3188: 95.<br />

14<br />

Annual Report of <strong>the</strong> Street Laying-Out Department for <strong>the</strong> year Ending February 1, 1915, City<br />

Document No. 32 (1915).<br />

5.0 Historic Resources 5-8


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

order to extend <strong>the</strong> street was passed at <strong>the</strong> end of June, and on August 21, 1914,<br />

<strong>the</strong> city received a license to do <strong>the</strong> necessary filling across <strong>the</strong> dock. The license<br />

specified that <strong>the</strong> north side of <strong>the</strong> new street was to be finished with a seawall,<br />

<strong>the</strong> south side was to be sloped, and <strong>the</strong> quadrilateral cut off at <strong>the</strong> end of <strong>the</strong> old<br />

dock (Figure 5-6) was to be filled solid to <strong>the</strong> grade of <strong>the</strong> street (italics added). 15<br />

The license does not specify, however, <strong>the</strong> kind of fill to be used. The extension<br />

or East First Street and filling of <strong>the</strong> dock-<strong>the</strong> part of <strong>the</strong> present SSA parcel now<br />

designated RTN-11965-was probably completed in 1914. Felton & Son <strong>the</strong>n<br />

acquired this newly made land in 1920 and 1921. 16<br />

In <strong>the</strong> years since <strong>the</strong> dock was filled <strong>the</strong>re have been more changes to <strong>the</strong> SSA<br />

parcel. The gasholder at <strong>the</strong> corner of E. Second and Dorchester Streets was<br />

evidently removed sometime between 1923 and 1930 (see above). Felton & Son<br />

did not acquire this land and <strong>the</strong> adjoining lot at <strong>the</strong> western tip of <strong>the</strong> parcel until<br />

1956, however. 17 (The present Neamco Office Products building at 510 East<br />

Second Street was reportedly constructed about 1966 on <strong>the</strong> site of <strong>the</strong> former<br />

gasholder. 18 ) In <strong>the</strong> 1930s <strong>the</strong>re was a railroad track, shown on a 1947 Sanborn<br />

atlas (Figure 5-8), on <strong>the</strong> site of <strong>the</strong> former dock in <strong>the</strong> north part of <strong>the</strong> parcel.<br />

The track was used for hauling molasses to <strong>the</strong> <strong>distillery</strong>, 19 and railroad cars can<br />

be seen on <strong>the</strong> north side of <strong>the</strong> Felton <strong>distillery</strong> in a photograph that appeared on<br />

<strong>the</strong> front of a 1938 booklet about <strong>the</strong> Felton & Son <strong>distillery</strong>. 20 About 1960 Felton<br />

& Son sold what is now <strong>the</strong> SSA parcel to Old Mr. <strong>Boston</strong>. 21 The latter continued<br />

to operate a <strong>distillery</strong> on <strong>the</strong> site until <strong>the</strong>y sold <strong>the</strong> property to Second Street<br />

Associates in 1982. 22<br />

15<br />

License No. 98, Directors of <strong>the</strong> Port of <strong>Boston</strong> to <strong>the</strong> City of <strong>Boston</strong>, August 21, 1914, Division of<br />

Wetlands and Waterways, [Massachusetts] Department of Environmental Protection, <strong>Boston</strong>, Mass.<br />

16<br />

S.D. 4224: 51, 4307: 109.<br />

17<br />

S.D. 7168: 381, 7200: 575.<br />

18<br />

ENSTRAT, Report on Project No. 049522-8.<br />

19<br />

Fred Gordon, personal communication.<br />

20<br />

West Peterson, The Romance of Rum: [History of New England's Famous Drink and Felton's Five<br />

Generations of Quality ([<strong>Boston</strong>]: , 1938).<br />

21<br />

Fred Gordon, personal communication.<br />

22 Ibid.<br />

5.0 Historic Resources 5-9


6.0 URBAN DESIGN<br />

6.1 Site Context<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The area of South <strong>Boston</strong> in which <strong>the</strong> site is located is historically on <strong>the</strong><br />

shoreline (see Chapter 5) which in <strong>the</strong> nineteenth and <strong>the</strong> twentieth centuries was<br />

heavily industrialized, <strong>the</strong> Distillery itself being an example of <strong>the</strong> type of land<br />

use prevalent throughout this period. As <strong>the</strong> shoreline was extended outwards on<br />

‘made land’ <strong>the</strong> new uses were primarily industrial. On <strong>the</strong> higher ground, in <strong>the</strong><br />

hinterland, is <strong>the</strong> residential neighborhood proper, extending south along<br />

Dorchester Street on both sides.<br />

Figure 6-1 Project Site in relation to South <strong>Boston</strong> neighborhood and seaport<br />

6.0 Urban Design 6-1


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Today <strong>the</strong> site is at <strong>the</strong> cusp of <strong>the</strong> industrial uses that abut First Street (to <strong>the</strong><br />

north) and <strong>the</strong> residential land uses that extend south to Broadway and beyond.<br />

On <strong>the</strong> northwest side of <strong>the</strong> site (on Dorchester Street) a former industrial site is<br />

being redeveloped as residential. To <strong>the</strong> east of <strong>the</strong> site, on H Street, <strong>the</strong> industrial<br />

land uses still prevail.<br />

Figure 6-2 View of Distillery site from Summer Street bridge<br />

6.2 Site Development and Massing<br />

The massing and disposition of <strong>the</strong> buildings on site are determined by <strong>the</strong><br />

following objectives:<br />

1. To create a strong edge to all four streets on <strong>the</strong> block.<br />

On Dorchester Street this objective is enriched by <strong>the</strong> additional desire to<br />

locate front doors to <strong>the</strong> residential units on this street in order to maximize<br />

pedestrian circulation. The elevation is given a vertical articulation with bay<br />

windows that also give residents views up and down <strong>the</strong> street.<br />

6.0 Urban Design 6-2


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 6-3 View up Dorchester Street from corner of East First Street<br />

Figure 6-4 View up Dorchester Street from corner of East Second Street<br />

On First Street <strong>the</strong> goal is to provide a strong edge to <strong>the</strong> trucking route,<br />

eliminating vehicular access on this frontage for safety reasons but at <strong>the</strong> same<br />

time providing pedestrian access to <strong>the</strong> live-work units and to <strong>the</strong> elevated<br />

courtyard from street level. At <strong>the</strong> corner of First and Dorchester <strong>the</strong>re is a<br />

major entrance to <strong>the</strong> entire complex. This entrance lobby rises through three<br />

stories from <strong>the</strong> street to a café and gallery at courtyard level, as well as to <strong>the</strong><br />

live-work and residential units. The stair rises through an extensively glazed<br />

6.0 Urban Design 6-3


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

lobby to permit views up and down First Street and to provide a lively, well lit<br />

elevation to passing traffic. A second stairway is located at mid-block giving<br />

access to <strong>the</strong> live-work units and <strong>the</strong> courtyard.<br />

The elevational treatment maintains <strong>the</strong> scale of <strong>the</strong> existing historic industrial<br />

buildings with which <strong>the</strong>y form a corner, and at <strong>the</strong> same time <strong>the</strong> mass is<br />

scaled down with small ‘juliet’ balconies and vertical patterns in <strong>the</strong><br />

brickwork at <strong>the</strong> party walls.<br />

Figure 6-5 View west along East First Street<br />

Figure 6-6 East First Street edge to Distillery site<br />

6.0 Urban Design 6-4


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The H Street elevation is an extension of <strong>the</strong> Distillery Building in general<br />

massing. This elevation also provides access to <strong>the</strong> lower level parking and to<br />

<strong>the</strong> loading bay for large trucks.<br />

2. To create of an edge condition on Second Street modified by <strong>the</strong> objective of<br />

creating an energy efficient footprint that maximizes solar exposure for<br />

sou<strong>the</strong>rn elevations and for <strong>the</strong> open courtyard space at <strong>the</strong> center of <strong>the</strong><br />

development.<br />

Figure 6-7 Interior courtyard elevation – sou<strong>the</strong>ast exposure<br />

The Second Street frontage will have <strong>the</strong> existing Distillery Building as one<br />

‘bookend’ to <strong>the</strong> street frontage. On <strong>the</strong> corner of Second and Dorchester <strong>the</strong>re<br />

will be a large volume greenhouse which will have exposure to sunshine for<br />

most of <strong>the</strong> day. As an urban design element it is intended to create a<br />

landmark at this important but o<strong>the</strong>rwise somewhat inchoate crossroads.<br />

Between <strong>the</strong> Distillery Building and <strong>the</strong> Greenhouse, <strong>the</strong> courtyard is open<br />

and penetrated by sunshine from morning until early afternoon. Next to <strong>the</strong><br />

Greenhouse will be a plinth (over <strong>the</strong> upper level parking) raised<br />

approximately 3 feet above sidewalk level that will be developed as an urban<br />

garden. At that height it will be easy for members of <strong>the</strong> pedestrians on <strong>the</strong><br />

Second Street sidewalk to see <strong>the</strong> garden itself and beyond into <strong>the</strong> planted<br />

courtyard. Between <strong>the</strong> plinth and <strong>the</strong> Distillery Building <strong>the</strong>re will be a 24’<br />

wide access point to <strong>the</strong> courtyard restricted to emergency and delivery<br />

vehicles.<br />

6.0 Urban Design 6-5


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 6-8 Interior courtyard – view from East Second Street<br />

3. To respond to <strong>the</strong> massing and volume of <strong>the</strong> existing historic structures on<br />

site which are approximately 65 feet above mean grade. The parapet level of<br />

<strong>the</strong> new buildings is calibrated as an extension of <strong>the</strong> existing eaves and<br />

parapet lines of <strong>the</strong> Distillery (on Second Street) and <strong>the</strong> Warehouse Building<br />

(on H Street). The heights of <strong>the</strong> new structures above mean grade for each of<br />

<strong>the</strong> streets are shown in Tables 3-1 and 3-2.<br />

Figure 6-9 H Street elevation of <strong>the</strong> existing buildings and proposed extension<br />

6.0 Urban Design 6-6


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

4. To modulate <strong>the</strong> slope of <strong>the</strong> hill from Second Street (elevation +32’) on <strong>the</strong><br />

sou<strong>the</strong>rn boundary of <strong>the</strong> site down to First Street (elevation +16.5’). While<br />

<strong>the</strong> roof line of <strong>the</strong> new buildings remains level, <strong>the</strong> relative height of <strong>the</strong> roof<br />

at <strong>the</strong> top of <strong>the</strong> hill, adjacent to <strong>the</strong> residential neighborhood, is less than it is<br />

at <strong>the</strong> bottom of <strong>the</strong> hill adjacent to <strong>the</strong> industrial / manufacturing uses and <strong>the</strong><br />

First Street through-route.<br />

Figure 6-10 Dorchester Street Elevation<br />

6.3 Space Allocation<br />

GALLERY<br />

Figure 6-11 Site plan and space allocation existing buildings<br />

proposed development<br />

6.0 Urban Design 6-7


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Four levels (Levels 3 to 6) of live-work and commercial units are placed on <strong>the</strong><br />

First Street frontage with a predominantly nor<strong>the</strong>rn orientation. These units will<br />

be serviced by <strong>the</strong> truck access off H Street.<br />

Four levels (Levels 3 to 6) of residential units are located on Dorchester Street<br />

facing north-west (over <strong>the</strong> street) and south-east (into <strong>the</strong> courtyard).<br />

Lower level parking (Level 1), serving all units above, is accessible from H Street<br />

and may be serviced by <strong>the</strong> large truck (40’) on H.<br />

Upper level parking (Level 2), serving all units above, is accessible from<br />

Dorchester Street and may be serviced by <strong>the</strong> box truck dock on Dorchester St.<br />

A café and an art gallery are located at <strong>the</strong> corner of Dorchester and First Street<br />

on Level 3, accessible from <strong>the</strong> street by stair and elevator, and from <strong>the</strong> courtyard<br />

(which is at level 3). This location gives patrons an excellent view of <strong>the</strong> street as<br />

<strong>the</strong>y wait for <strong>the</strong> bus (or a ride) to pick <strong>the</strong>m up. The bright lights and signage of<br />

<strong>the</strong> café will also provide a welcome landmark on First Street.<br />

A greenhouse for growing vegetables is located at level 4 on <strong>the</strong> corner of<br />

Dorchester and Second Street, accessible from <strong>the</strong> street by stair and elevator. The<br />

south facing glazing of <strong>the</strong> greenhouse is not only very functional but will also<br />

provide an iconic corner characteristic as <strong>the</strong> signature statement of <strong>the</strong> new green<br />

building on <strong>the</strong> edge of <strong>the</strong> residential neighborhood.<br />

6.0 Urban Design 6-8


6.4 Access and Circulation<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 6-12 Pedestrian and Vehicular Access<br />

Pedestrian access Vehicular access<br />

The principal pedestrian approach to <strong>the</strong> site is from Broadway (where most of<br />

<strong>the</strong> buses run) down Dorchester Street. There are pedestrian access points – front<br />

doors – to each group of residential units along <strong>the</strong> Dorchester Street frontage. In<br />

addition <strong>the</strong>re is open access from <strong>the</strong> Second Street sidewalk to <strong>the</strong> courtyard,<br />

leading to a reception area, galleries and café and <strong>the</strong> live-work studios both in <strong>the</strong><br />

new building and <strong>the</strong> existing. From First Street <strong>the</strong>re is a major pedestrian<br />

entrance at <strong>the</strong> corner of First and Dorchester where <strong>the</strong>re is a three-storey lobby<br />

leading to <strong>the</strong> café and <strong>the</strong> courtyard. The lobby is served by elevators and a<br />

generous staircase.<br />

It is envisioned that a convenience food store will occupy <strong>the</strong> commercial site at<br />

<strong>the</strong> corner of Dorchester and E. Second Street. The store will be accessed by a<br />

6.0 Urban Design 6-9


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

handicap access ramp, which will serve also non-handicap entrance from E.<br />

Second Street. This ramp will join stairs access coming up from <strong>the</strong> corner of<br />

Dorchester Street and E. First. The store will <strong>the</strong>reby invite entrance from its own<br />

residents (and o<strong>the</strong>rs on Second Street), and from <strong>the</strong> broader neighborhood to <strong>the</strong><br />

south and west.<br />

Supplementary pedestrian access points are located at H Street adjacent to <strong>the</strong><br />

lower parking entrance, <strong>the</strong> freight elevator and <strong>the</strong> loading dock, as well as on<br />

<strong>the</strong> upper end of H Street into <strong>the</strong> existing Distillery building; and on Second<br />

Street at <strong>the</strong> corner of <strong>the</strong> retail store, leading into <strong>the</strong> store itself and to <strong>the</strong><br />

Greenhouse above. This route is also served by an elevator.<br />

Vehicular access points are located at H Street for lower level parking; at<br />

Dorchester Street for upper level parking; and at Second Street for access to <strong>the</strong><br />

courtyard (for emergency vehicles). A loading dock is provided at H Street<br />

allowing large trucks to load and unload off-street and have direct access to <strong>the</strong><br />

freight elevator that serves both <strong>the</strong> new live-work units and <strong>the</strong> existing building.<br />

Access for <strong>the</strong> corner retail store will be from a loading dock located in <strong>the</strong> upper<br />

level parking off Dorchester Street.<br />

There is an even distribution of vehicle access points between three of <strong>the</strong> four<br />

surrounding streets. First Street is not used as an access point for vehicles because<br />

it is a busy through-route.<br />

H Street is used as access to <strong>the</strong> lower parking and for <strong>the</strong> loading dock because it<br />

is <strong>the</strong> least heavily trafficked and poses least interference, disruption or danger.<br />

Second Street serves <strong>the</strong> delivery trucks (USPS, UPS, FedEx etc) and emergency<br />

vehicles.<br />

For alternative access points reviewed see Chapter 9.<br />

6.0 Urban Design 6-10


7.0 ARCHITECTURE<br />

7.1 Architectural expression<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The architectural expression and choice of materials for <strong>the</strong> project is influenced<br />

firstly by several considerations. It is influenced firstly by <strong>the</strong> strong architectural<br />

character of <strong>the</strong> existing Distillery building—a traditional, industrial, loadbearing<br />

brick structure characterized by identical punched windows on all elevations.<br />

Secondly, by <strong>the</strong> requirement to create a transition from that industrial vernacular<br />

to an architectural form more expressive of, and sympa<strong>the</strong>tic to, new uses for <strong>the</strong><br />

proposed development. This is to be reflected in <strong>the</strong> use of new materials and<br />

more variation in scale. Thirdly, it is influenced by <strong>the</strong> prominence of <strong>the</strong><br />

building. Although well-embedded in <strong>the</strong> urban fabric, it is fully visible both<br />

from a long distance (Figure 7-1 - Summer Street Bridge over <strong>the</strong> Reserve<br />

Channel) and from close quarters (particularly along <strong>the</strong> residential streets of<br />

Second Street and Dorchester Street). Lastly, <strong>the</strong> form and materials of <strong>the</strong><br />

building are influenced by <strong>the</strong> energy performance considerations. This is to a<br />

large extent dependent on <strong>the</strong> relative balance of window and wall, and <strong>the</strong><br />

requirement for carefully designed overhangs to provide summer shading of<br />

windows while maximizing passive heat gain during <strong>the</strong> heating season. See<br />

Table 7-1 at <strong>the</strong> end of this section for a summary of building materials.<br />

Figure 7-1 View from Summer Street bridge<br />

7.0 Architecture 7-1


7.2 H Street Elevation<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The H Street elevation (Figure 7-2) features a wall characterized by <strong>the</strong> loading<br />

dock and vehicle access point with a series of punched windows (facing due east).<br />

The window to unit floor area will be kept below 5%, as is recommended for<br />

passive heating on east exposures. The principal design issue here is <strong>the</strong> decision<br />

as to whe<strong>the</strong>r to match <strong>the</strong> existing brickwork of <strong>the</strong> Warehouse or to make a<br />

distinct addition. Given <strong>the</strong> age and wea<strong>the</strong>ring of <strong>the</strong> existing brickwork, a<br />

distinction is favored using composite or limestone panels as a complement to <strong>the</strong><br />

brick.<br />

Figure 7-2 H Street elevation<br />

7.3 East First Street Elevation<br />

East First Street is a busy truck route and <strong>the</strong> wall of <strong>the</strong> new building is facing<br />

due north (Figure 7-3). It is anticipated that snow and ice buildup, plus spattering<br />

of salt spray from passing vehicles, makes for a harsh, cold environment. The<br />

parking garage walls will be of concrete with a distinctive formwork pattern; this<br />

part of <strong>the</strong> wall will be punctuated with fresh air intake ventilation grills. Above<br />

<strong>the</strong> parking levels <strong>the</strong> elevation will be of brick with windows and balconies<br />

(serving <strong>the</strong> live-work spaces) distributed evenly throughout. The main field of<br />

brickwork will be a warm russet color with vertical accents at each party wall<br />

(and movement joint) in a dark blue-gray ironspot. Balconies and window trim<br />

will be set off in an attractive color.<br />

7.0 Architecture 7-2


Figure 7-3 East First Street elevation<br />

7.4 Dorchester Street Elevation<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Dorchester Street will have a residential character on both sides of <strong>the</strong> street.<br />

Street trees on both sides will start at <strong>the</strong> bottom of <strong>the</strong> hill and continue up<br />

beyond Second Street to enhance this residential neighborhood character. The<br />

building itself is designed to have front doors on <strong>the</strong> sidewalk, serving all of <strong>the</strong><br />

new residential apartments (Figure 7-4). At <strong>the</strong> lower end of <strong>the</strong> site, building<br />

entrances will be flanked by retail storefronts. At <strong>the</strong> top of <strong>the</strong> street at <strong>the</strong> corner<br />

<strong>the</strong>re will be a convenience food store accessible from Second Street. At <strong>the</strong><br />

bottom of <strong>the</strong> hill on <strong>the</strong> corner with First Street, <strong>the</strong> main entrance to <strong>the</strong> building<br />

complex and access to <strong>the</strong> café and galleries will be located, presenting a<br />

welcoming transparent face to passing motorists and pedestrians. On Dorchester<br />

Street itself, <strong>the</strong> elevation of <strong>the</strong> building is given a regular articulation with metal<br />

clad bay windows set against a main wall clad in limestone or artificial stone<br />

cladding panels (Figure 7-5).<br />

Figure 7-4 Dorchester Street elevation<br />

7.0 Architecture 7-3


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 7-5 View up Dorchester Street from corner of East First Street<br />

7.5 East Second Street Elevation<br />

The proposed development does not present an elevation directly on East Second<br />

Street. However <strong>the</strong> courtyard elevations are highly visible from East Second<br />

Street (Figure 7-6). The treatment to this more ‘interior’ elevation is warmer,<br />

softer and more subtle than on <strong>the</strong> outer faces. The cladding will be in natural<br />

cedar punctuated by windows and doors accented with color. Balconies and<br />

sunscreens will be constructed of semi-transparent perforated metal to give<br />

residents a view downwards and to convey a feeling of lightness on <strong>the</strong> face of <strong>the</strong><br />

building. There will also be an opportunity to grow plants on this sou<strong>the</strong>rn aspect<br />

of <strong>the</strong> building. Ano<strong>the</strong>r major feature of <strong>the</strong> Second Street / Dorchester Street<br />

corner will be <strong>the</strong> transparent greenhouse (Figure 7-7) which will be a production<br />

unit for growing vegetables, some of which will be sold in <strong>the</strong> retail store below.<br />

7.0 Architecture 7-4


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 7-6 Distillery courtyard from East Second Street<br />

7.6 Roofscape<br />

As described in <strong>the</strong> landscape architecture section of this report, <strong>the</strong> roofs and<br />

courtyard will act as ‘gardens’ for <strong>the</strong> growth of vegetable produce. In addition<br />

<strong>the</strong> roof lights to <strong>the</strong> atriums will provide a characteristic and attractive roofscape<br />

for those neighbors who will look down on <strong>the</strong> development from higher<br />

elevations up <strong>the</strong> hill (Figure 7-7). The use of <strong>the</strong> roof for vegetable gardens, as a<br />

place for roof decks for people to sit out on, and as a ga<strong>the</strong>ring place is important<br />

to <strong>the</strong> concept of <strong>the</strong> building. The design is intended to reduce <strong>the</strong> windswept<br />

environment and to maximize <strong>the</strong> use of <strong>the</strong> roof as a place for gardens,<br />

penthouses, as well as accommodating <strong>the</strong> elevator headhouses and atria, staying<br />

within <strong>the</strong> requirement of one third of <strong>the</strong> total roof area for such uses.<br />

7.0 Architecture 7-5


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 7-7 Distillery courtyard and roofscape from above East Second Street<br />

TABLE 7-1 PROPOSED MATERIALS FOR BUILDING FACADES<br />

H Street Elevation<br />

limestone clad or artificial stone cladding panels<br />

East First Street Elevation concrete for parking garage<br />

brick (warm russet and dark blue-gray)<br />

Dorchester Street Elevation metal clad bay windows<br />

limestone clad or artificial stone cladding panels<br />

East Second Street Elevation natural cedar punctuated by windows and doors accented with color<br />

semi-transparent perforated metal balconies<br />

glass for greenhouse at corner of East 2nd and Dorchester Streets.<br />

7.0 Architecture 7-6


8.0 LANDSCAPE ARCHITECTURE<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

It is <strong>the</strong> objective of <strong>the</strong> landscape plan for <strong>the</strong> development to provide an<br />

attractive and reasonably hardy streetscape and, particularly within <strong>the</strong><br />

development, to provide a productive horticulture that will consist of trees and<br />

bushes bearing fruits and berries and extensive areas of fruit and vegetable<br />

annuals. The landscape aes<strong>the</strong>tic within <strong>the</strong> complex is <strong>the</strong>refore based on <strong>the</strong> idea<br />

that a productive landscape is also an attractive one.<br />

The landscape architecture of <strong>the</strong> development is treated in three areas:<br />

8.1 Street Landscape<br />

It is <strong>the</strong> intention of <strong>the</strong> developer to work with <strong>the</strong> BRA in determining an<br />

appropriate paving and planting scheme for all four abutting sidewalks. Tree<br />

planting is envisioned for Dorchester Street and Second Street. On First Street this<br />

may be problematic firstly because it is situated in shadow; and secondly it is<br />

likely to suffer from salt spray thrown up by heavy truck traffic.<br />

8.2 The Courtyard<br />

Fig 8-1 Dorchester Street planting<br />

The courtyard has to be paved and structured for emergency vehicle access and<br />

must allow for pick-up and drop-off services such as <strong>the</strong> mail, laundry or <strong>the</strong><br />

occasional maintenance vehicle. Hard standing will be provided by ‘grascrete’ or<br />

8.0 Landscape Architecture 8-1


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

similar paving type materials that allow for vegetation to grow within a structural<br />

matrix.<br />

Fig 8-2 Courtyard planting<br />

The courtyard will also be planted with fruit trees with an underplanting of<br />

productive bushes. The basement of <strong>the</strong> former boiler house (to be demolished)<br />

will serve as a hardscape for ball games, barbecues and occasional block parties.<br />

The plinth (<strong>the</strong> roofed area over <strong>the</strong> upper level parking spaces extending along<br />

Second Street) will be used for intensive vegetable cultivation by residents.<br />

8.3 The Roof<br />

The roof will be used for relaxation and gardening. There are two elevator access<br />

points to <strong>the</strong> roof (one on Dorchester Street, <strong>the</strong> o<strong>the</strong>r on First Street) and seven<br />

staircase access points. Most of <strong>the</strong> areas designated for gardening will consist of<br />

elevated beds (approximately 24” above <strong>the</strong> paving) to provide for <strong>the</strong> required<br />

depth of soil.<br />

Fig 8-3 Roof landscape<br />

8.0 Landscape Architecture 8-2


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Each of <strong>the</strong> Dorchester Street stair headhouses will have a small greenhouse leanto<br />

for use by residents. Each of <strong>the</strong> atrium modules will have use of seating and<br />

gardening space protected from <strong>the</strong> wind. On <strong>the</strong> First Street roof, <strong>the</strong> gardening<br />

area will be distributed amongst residents in <strong>the</strong> live-work units below. Ano<strong>the</strong>r<br />

characteristic feature of <strong>the</strong> Dorchester Street roofs will be <strong>the</strong> glazed headhouse<br />

to each of five atriums. The headhouses will also contain heliostat mirror systems<br />

to direct sunlight into <strong>the</strong> atrium.<br />

A parapet railing will run around <strong>the</strong> entire roof.<br />

8.0 Landscape Architecture 8-3


9.0 TRANSPORTATION ACCESS PLAN COMPONENT<br />

9.1 Introduction<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

This chapter of <strong>the</strong> Expanded Project Notification Form (PNF) for <strong>the</strong> Rum<br />

Distillery project (referred to as <strong>the</strong> “Distillery project”), presents an evaluation<br />

and summary of existing and future transportation aspects of <strong>the</strong> project. The<br />

transportation study has been performed in order to understand and mitigate any<br />

potential transportation impacts of <strong>the</strong> proposed Distillery project, and provide a<br />

Transportation Access Plan in accordance with Article 80 of <strong>the</strong> City of <strong>Boston</strong><br />

Zoning Code. The Transportation Access Plan includes an analysis of <strong>the</strong><br />

following:<br />

• Vehicular traffic on study area roadways and intersections;<br />

• Parking conditions;<br />

• Loading and service activities;<br />

• Pedestrian and bicycle activities; and<br />

• Public transportation and private shuttle bus services.<br />

In addition to quantifying existing conditions, <strong>the</strong> analysis assesses <strong>the</strong><br />

transportation impacts that are expected in <strong>the</strong> study area under future conditions,<br />

with and without <strong>the</strong> Distillery project. This chapter is presented in four sections,<br />

as follows:<br />

Existing Conditions<br />

Defines and quantifies existing transportation conditions in <strong>the</strong> project study area<br />

as defined by <strong>the</strong> <strong>Boston</strong> Transportation Department (BTD);<br />

9.0 Transportation Access Plan 9-1


Future Conditions<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Projects <strong>the</strong> expected future transportation conditions in <strong>the</strong> study area, and<br />

identifies <strong>the</strong> transportation impacts that might occur as a result of <strong>the</strong> Distillery<br />

project;<br />

Traffic Operations Analysis<br />

Presents a capacity and operational analysis at study area intersections under<br />

existing and future conditions; and<br />

Transportation Improvement Plan<br />

Develops a set of improvement strategies and actions that will address any<br />

transportation effects of <strong>the</strong> Distillery project and improve <strong>the</strong> transportation<br />

infrastructure in <strong>the</strong> surrounding area.<br />

The remainder of this Introduction section includes an overview of <strong>the</strong> Distillery<br />

project, <strong>the</strong> definition of <strong>the</strong> study area and <strong>the</strong> transportation analysis<br />

methodology.<br />

9.1.1 Project Description<br />

The Distillery project is located on a parcel of land, originally used as a rum<br />

<strong>distillery</strong>, abutting East First Street to <strong>the</strong> north, East Second Street to <strong>the</strong> south,<br />

Dorchester Street to <strong>the</strong> west and H Street to <strong>the</strong> east, in South <strong>Boston</strong>. The<br />

location of <strong>the</strong> site is shown in Figure 9-1. The site comprises approximately<br />

75,618 square feet of land and is currently occupied by three buildings.<br />

As proposed, <strong>the</strong> Distillery project will maintain one existing building, <strong>the</strong> 6-story<br />

brick Distillery / Warehouse building, and demolish <strong>the</strong> remaining two buildings,<br />

<strong>the</strong> Honeywell Building (former bottling plant) and Cooper’s Shop. Two new<br />

buildings will be built, accommodating 124,996 gross square foot (GSF) of<br />

commercial space, live-work space, residential units, retail, a café, a greenhouse<br />

and two galleries, with dedicated on-site parking (refer to Chapter 2 and Table 3-<br />

9.0 Transportation Access Plan 9-2


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

3 for details). The project thus comprises <strong>the</strong> addition of two new buildings, <strong>the</strong><br />

tallest of which is 6-stories high and will include <strong>the</strong> following components (see<br />

also Table 2-4):<br />

• 25 Live-Work Studios (28,755 nsf)<br />

• 44 Residential Units (58,751 nsf)<br />

• Retail space (2,126 nsf)<br />

• Café (1,584 nsf)<br />

• Greenhouse (1,319 nsf)<br />

• Gallery (868 nsf)<br />

• Gallery (1,324 nsf)<br />

• TOTAL 94,727 NSF<br />

The project proposes 123 total parking spaces to support <strong>the</strong> entire site, an<br />

increase of 57 spaces over <strong>the</strong> existing 66 surface parking spaces (see Tables 2-1<br />

and 2-5). 99 spaces will be allocated to <strong>the</strong> residential components (for 30<br />

existing + 69 new units), and <strong>the</strong> remaining 24 spaces will support <strong>the</strong><br />

commercial and retail space. The need for private automobile access is expected<br />

to be lower than for similar developments in <strong>the</strong> city due to access to existing<br />

public transportation services, <strong>the</strong> mixed-use nature of <strong>the</strong> development program,<br />

and <strong>the</strong> aggressive alternative transportation options that are being proposed. A<br />

detailed discussion of expected on-site parking demand and operations is<br />

presented later in this chapter.<br />

9.1.2 Study Area<br />

The project study area includes 5 intersections that have been specifically defined<br />

for analysis by <strong>the</strong> BTD. These intersections, illustrated in Figure 9-2, are as<br />

follows:<br />

1. East First Street at West First Street/Pappas Way<br />

2. East First Street at Dorchester Street<br />

9.0 Transportation Access Plan 9-3


3. East First Street at H Street<br />

4. East Second Street at Dorchester Street<br />

5. East Second Street at H Street<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

In addition, <strong>the</strong> project site driveways are included in <strong>the</strong> analysis.<br />

Figure 9-1 Site Location<br />

9.0 Transportation Access Plan 9-4


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 9-2 Study Area Intersections and MBTA Bus Stop Locations<br />

9.0 Transportation Access Plan 9-5


9.1.3 Study Methodology<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Although <strong>the</strong> <strong>Boston</strong> Transportation Department (BTD) has not issued a formal<br />

Transportation Access Plan Scope, <strong>the</strong> transportation analysis presented in this<br />

chapter conforms to <strong>the</strong> BTD “Transportation Access Plans Guidelines” (2001).<br />

The analysis has been developed to be responsive to <strong>the</strong> BTD through a number<br />

of preliminary meetings and discussions.<br />

The analysis of Existing Conditions included a survey and compilation of existing<br />

transportation conditions within <strong>the</strong> study area, including:<br />

• An inventory of <strong>the</strong> transportation infrastructure within <strong>the</strong> defined project<br />

study area;<br />

• Transportation characteristics of <strong>the</strong> proposed site, including access, egress,<br />

parking, loading activities, shuttle bus activities, and truck activities;<br />

• Geometric and operational characteristics of study area roadways and<br />

intersections;<br />

• Existing traffic control at study area intersections (i.e., traffic signalization,<br />

stop signs, one-way streets, etc.);<br />

• Area off-street and on-street parking supply, demands, turnover, availability,<br />

and rates;<br />

• An inventory of study area sidewalks and crosswalks;<br />

• Pedestrian activity and bicycle accommodations along study area roadways,<br />

and at study area intersections;<br />

• Public transportation options within <strong>the</strong> study area, including bus and subway<br />

options, and existing capacity by specific transit service type.<br />

9.0 Transportation Access Plan 9-6


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

In <strong>the</strong> evaluation of Future Conditions, future transportation conditions were<br />

analyzed within <strong>the</strong> study area. The future no-build conditions (without <strong>the</strong><br />

Distillery project) were developed by analyzing projected roadway volumes for a<br />

5-year time horizon, to <strong>the</strong> year 2011. The future build condition (with <strong>the</strong><br />

Distillery project) assesses <strong>the</strong> addition of <strong>the</strong> proposed project and supporting<br />

transportation improvements to <strong>the</strong> 2011 no-build conditions. The future<br />

conditions analysis includes evaluation of pedestrian, transit, parking and loading<br />

aspects of <strong>the</strong> project, as well as traffic operations for <strong>the</strong> morning and evening<br />

peak commuter periods. Hence, <strong>the</strong> transportation study addresses three<br />

conditions, as follows:<br />

• 2006 Existing Conditions<br />

• 2011 No-Build Conditions<br />

• 2011 Build Conditions<br />

Based on <strong>the</strong> evaluation of existing conditions, as well as <strong>the</strong> identified projectrelated<br />

effects of <strong>the</strong> Distillery project to pedestrian, parking, traffic, and public<br />

transportation conditions, a comprehensive package of improvement actions was<br />

developed, described in detail later in this chapter. The proposed improvement<br />

actions serve as <strong>the</strong> basis for a Transportation Access Plan Agreement (TAPA) to<br />

be developed and executed by both <strong>the</strong> proponent and <strong>the</strong> BTD.<br />

Finally, <strong>the</strong> project’s short-term impacts due to construction activity are evaluated<br />

as a basis for a Construction Management Plan to be approved by <strong>the</strong> BTD.<br />

9.1.4 Summary of Findings<br />

The primary finding of <strong>the</strong> transportation analysis is that <strong>the</strong> Distillery project will<br />

have no significant impact on <strong>the</strong> transportation infrastructure in South <strong>Boston</strong>.<br />

The proposed project will add approximately 110 AM and 80 PM peak hour trips<br />

to area roadways. As <strong>the</strong>se trips will be distributed in several directions, no<br />

adverse operational or capacity impacts are expected. The neighborhood is also<br />

9.0 Transportation Access Plan 9-7


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

well served by transit, with ample service available within a few-minutes walk of<br />

<strong>the</strong> site to accommodate anticipated transit demand from <strong>the</strong> project.<br />

Additionally, <strong>the</strong> proponent has developed a package of transportation<br />

improvements and actions that will provide artists, residents, and visitors with<br />

additional and improved access choices to <strong>the</strong> project site, including<br />

• Intersection safety improvements;<br />

• Parking management strategies;<br />

• Transportation demand management enhancements;<br />

• Pedestrian access and open space improvements; and<br />

• Construction management actions.<br />

The proposed Transportation Demand Management (TDM) incentives to residents<br />

and employees at <strong>the</strong> Distillery project will promote <strong>the</strong> use of public<br />

transportation and o<strong>the</strong>r alternative modes of travel that will help to reduce <strong>the</strong><br />

amount of single occupant vehicles in <strong>the</strong> area and decrease <strong>the</strong> demand for onsite<br />

parking. Taken toge<strong>the</strong>r, <strong>the</strong>se measures will ensure that <strong>the</strong> project will have<br />

minimal impact on neighborhood transportation services, and indeed may benefit<br />

<strong>the</strong> existing neighborhood.<br />

9.0 Transportation Access Plan 9-8


9.2 EXISTING CONDITIONS<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Existing transportation conditions in <strong>the</strong> study area, including roadway geometry,<br />

traffic controls, peak hour traffic and pedestrian flows, transit availability, parking<br />

supply and utilization, and loading and service activities are described in this<br />

section of <strong>the</strong> transportation chapter. The existing access characteristics of <strong>the</strong><br />

project site are specifically described, and transportation characteristics of <strong>the</strong><br />

entire study area are quantified.<br />

The project site, located in South <strong>Boston</strong>, is currently occupied by three buildings<br />

The project will complement <strong>the</strong> surrounding area by helping to streng<strong>the</strong>n a<br />

transition zone between <strong>the</strong> residential neighborhood to <strong>the</strong> south and <strong>the</strong> more<br />

industrial activity to <strong>the</strong> north of <strong>the</strong> site while supporting artists’ working and<br />

living environments and providing some neighborhood-serving retail uses.<br />

This section describes <strong>the</strong> existing transportation infrastructure including roadway<br />

geometry, intersection conditions, parking supply and demand, crash analysis,<br />

public transportation, and pedestrian and bicycle facilities. Existing traffic and<br />

pedestrian volumes are presented, but capacity and operational analysis of study<br />

intersections is presented later in <strong>the</strong> chapter along with <strong>the</strong> corresponding<br />

analysis of future no-build and build conditions.<br />

9.2.1 Existing Roadway Conditions<br />

The study area includes <strong>the</strong> following four roadways:<br />

East First Street is an urban minor arterial that runs in a general east-west<br />

direction from Farrago Road to <strong>the</strong> east to West First Street near <strong>the</strong> project site.<br />

Generally, <strong>the</strong>re are two lanes in each direction and <strong>the</strong> roadway is 80 feet wide in<br />

<strong>the</strong> vicinity of <strong>the</strong> project site. Adjacent to <strong>the</strong> project site and to <strong>the</strong> east, parking<br />

is available on <strong>the</strong> north side of <strong>the</strong> street. Pavement markings along East First<br />

Street are in faded condition. Generally, <strong>the</strong>re are sidewalks on both sides of East<br />

First Street, although <strong>the</strong> sidewalk is in poor condition adjacent to and opposite<br />

<strong>the</strong> project site and is limited to 4-feet in width in some locations.<br />

9.0 Transportation Access Plan 9-9


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Dorchester Street is an urban minor arterial that runs in a general nor<strong>the</strong>astsouthwest<br />

direction from its intersection with East First Street adjacent to <strong>the</strong> site<br />

southwest to Andrew Square, where it intersects with Preble Street, Dorchester<br />

Avenue, Southampton Street and <strong>Boston</strong> Street. Dorchester Street is 34 feet wide<br />

and <strong>the</strong>re is one lane in each direction near <strong>the</strong> project site, with parking allowed<br />

on both sides of <strong>the</strong> street. There are sidewalks on both sides of East First Street,<br />

with newer sidewalks adjacent and across from <strong>the</strong> project site. There are no<br />

pavement markings on Dorchester Street.<br />

East Second Street is an urban minor arterial abutting <strong>the</strong> south side of <strong>the</strong> project<br />

site. It runs east-west between M Street and West First Street at <strong>the</strong> southwest<br />

corner of <strong>the</strong> project site. East Second Street is 34 feet wide and has one lane in<br />

each direction. Parking is permitted on both sides of East Second Street. There<br />

are sidewalks on both sides of <strong>the</strong> street. There are no pavement markings on<br />

East Second Street.<br />

H Street is an urban minor arterial abutting <strong>the</strong> east side of <strong>the</strong> project site. It runs<br />

in a north-south direction, between East First Street at <strong>the</strong> nor<strong>the</strong>ast corner of <strong>the</strong><br />

project site, south to Columbia Road. H Street is 34 feet wide and is one-way<br />

with one lane in <strong>the</strong> northbound direction. Parking is permitted on both sides of<br />

<strong>the</strong> street. Sidewalks are provided on both sides of H Street, however across H<br />

Street from <strong>the</strong> project site, <strong>the</strong> lack of a curb makes <strong>the</strong> sidewalk<br />

indistinguishable from <strong>the</strong> street; field observations revealed that parked cars<br />

encroached on pedestrian space. There are no pavement markings on H Street.<br />

9.2.2 Study Area Intersections<br />

As discussed previously, <strong>the</strong> project study area includes 5 intersections defined by<br />

<strong>the</strong> BTD (see Figure 9-2). The following descriptions of <strong>the</strong> 5 study area<br />

intersections include physical characteristics, geometric conditions, pedestrian<br />

facilities, and traffic control measures. Again, intersection capacity and<br />

operational analysis is presented later in this chapter.<br />

9.0 Transportation Access Plan 9-10


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

1. East First Street / West First Street/Pappas Way is an off-set 4-way<br />

unsignalized intersection. East First Street intersects West First Street at an angle,<br />

with Pappas Way, a private roadway, intersecting East First Street about 50 feet to<br />

<strong>the</strong> east of West First Street. The West First Street northbound and Pappas Way<br />

southbound approaches are stop-sign controlled. There is one travel lane<br />

provided in each direction on all approaches. Parking is allowed on both sides of<br />

East and West First Street. Sidewalks are provided on West First Street, but <strong>the</strong>re<br />

are no sidewalks on East First Street near <strong>the</strong> intersection. There are no marked<br />

crosswalks at this intersection<br />

2. East First Street / Dorchester Street is an unsignalized three-legged<br />

intersection with a fourth leg being a driveway onto private property. All<br />

approaches provide one lane in each direction. The Dorchester Street northbound<br />

approach is stop-sign controlled. There is unrestricted parking on Dorchester<br />

Street and <strong>the</strong> south side of East First Street, but no parking allowed on <strong>the</strong> north<br />

side of East First Street. Sidewalks are provided on <strong>the</strong> south side of East First<br />

Street and on <strong>the</strong> Dorchester Street approaches, but <strong>the</strong>re is only a nominal<br />

sidewalk on <strong>the</strong> north side of East First Street. There are no marked crosswalks at<br />

this intersection, but <strong>the</strong>re is an ADA-accessible curb cut on <strong>the</strong> southwest corner<br />

of <strong>the</strong> intersection.<br />

3. East First Street / H Street is an unsignalized three-legged intersection with a<br />

fourth leg being a private driveway as <strong>the</strong> north leg of <strong>the</strong> intersection. The<br />

eastbound and westbound East First Street approaches provide one lane in each<br />

direction. H Street is one-way with one lane in <strong>the</strong> northbound direction. The H<br />

Street northbound approach is stop-sign controlled. No parking is allowed on <strong>the</strong><br />

East First Street eastbound approach at this intersection. Unrestricted parking is<br />

allowed on <strong>the</strong> south side of East First Street east of <strong>the</strong> intersection and along H<br />

Street. Sidewalks are provided on <strong>the</strong> south side of East First Street and on both<br />

sides of H Street. There are no marked crosswalks at this intersection.<br />

9.0 Transportation Access Plan 9-11


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

4. East Second Street / Dorchester Street/West First Street is a four-legged<br />

unsignalized intersection. There is one travel lane at each approach to <strong>the</strong><br />

intersection. The East Second Street westbound and West First Street eastbound<br />

approaches are stop-sign controlled. Parking is allowed on both sides of each<br />

approach. However, <strong>the</strong>re are multiple curb cuts along <strong>the</strong> sou<strong>the</strong>rn side of East<br />

Second Street serving adjacent businesses. Sidewalks are provided along all<br />

intersection approaches. There are no marked crosswalks at this intersection, but<br />

<strong>the</strong>re are ADA-accessible ramps at all corners except <strong>the</strong> sou<strong>the</strong>astern corner of<br />

<strong>the</strong> intersection.<br />

5. East Second Street / H Street is an un-signalized four-legged intersection.<br />

The East Second Street approach provides one lane in each direction and H Street<br />

is one-way with one lane in <strong>the</strong> northbound direction. The H Street northbound<br />

and southbound approaches are stop-sign controlled. Unrestricted parking is<br />

allowed on both sides of all approaches to <strong>the</strong> intersection. Sidewalks are<br />

provided along all intersection approaches. There are no marked crosswalks<br />

provided at this intersection, although <strong>the</strong>re are ADA-accessible ramps at all<br />

corners except <strong>the</strong> sou<strong>the</strong>astern corner.<br />

9.2.3 Existing Traffic Volumes<br />

An extensive transportation data collection program was conducted, including<br />

morning and evening peak hour turning movement counts (TMCs) from 7:00 to<br />

9:00 AM and from 4:00 to 6:00 PM at all study area intersections. In addition, an<br />

automatic traffic recorder (ATR) count was conducted for 48 hours along East<br />

First Street between Dorchester Street and H Street. Traffic count data are<br />

included in <strong>the</strong> Transportation Appendix and are summarized below.<br />

Average Weekday Daily Traffic Counts<br />

Hourly traffic activity on East First Street is presented in Table 9-1. The data<br />

represent <strong>the</strong> averages of data collected over two weekdays.<br />

9.0 Transportation Access Plan 9-12


Table 9-1 Average Weekday Daily Traffic Summary<br />

Hour Beginning<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

East First Street (between Dorchester Street and H Street)<br />

Westbound<br />

Volume<br />

Eastbound<br />

Volume<br />

Total for<br />

9.0 Transportation Access Plan 9-13<br />

Both<br />

Directions<br />

Peak<br />

Direction<br />

Percent in<br />

Peak<br />

Direction<br />

Midnight 13 9 21 WB 60%<br />

1:00 AM 8 7 15 WB 52%<br />

2:00 AM 6 2 8 WB 75%<br />

3:00 AM 7 5 12 WB 58%<br />

4:00 AM 13 17 30 EB 57%<br />

5:00 AM 59 58 117 WB 50%<br />

6:00 AM 142 121 263 WB 54%<br />

7:00 AM 218 141 358 WB 61%<br />

8:00 AM 269 139 408 WB 66%<br />

9:00 AM 187 154 340 WB 55%<br />

10:00 AM 146 156 302 EB 52%<br />

11:00 AM 171 157 328 WB 52%<br />

Noon 183 153 336 WB 54%<br />

1:00 PM 119 156 275 EB 57%<br />

2:00 PM 116 141 257 EB 55%<br />

3:00 PM 134 184 318 EB 58%<br />

4:00 PM 170 133 302 WB 56%<br />

5:00 PM 154 138 292 WB 53%<br />

6:00 PM 127 118 244 WB 52%<br />

7:00 PM 112 129 241 EB 54%<br />

8:00 PM 82 75 156 WB 52%<br />

9:00 PM 44 47 91 EB 51%<br />

10:00 PM 47 39 85 WB 55%<br />

11:00 PM 31 26 56 WB 54%<br />

Daily Total 2,552 2,300 4,852 WB 53%<br />

Source: ATR counts conducted by Vanasse Hangen Brustlin, Inc. from Tuesday<br />

August 2 through Wednesday August 3, 2006


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

On East First Street between Dorchester Street and H Street, <strong>the</strong> average weekly<br />

daily traffic (AWDT) is approximately 4,850 vehicles, with more traffic traveling<br />

westbound during <strong>the</strong> majority of each hourly period. Hourly traffic volumes are<br />

highest during <strong>the</strong> morning peak period (7 to 10 AM), with a total of just over 400<br />

vehicles in <strong>the</strong> peak hour, 8 to 9 AM. The evening peak period occurs quite early<br />

in <strong>the</strong> afternoon, with <strong>the</strong> peak hour volume of almost 320 vehicles occurring<br />

between 3 to 4 PM.<br />

Peak Hour Traffic Volumes<br />

Manual turning movement/classification counts (TMCs) were conducted on July<br />

27th, 2006 at each of <strong>the</strong> 5 study area intersections. As requested by <strong>the</strong> BTD,<br />

TMCs were conducted from 7 to 9 AM and from 4 to 6 PM.<br />

The intersection turning movement counts were used to develop 2006 Existing<br />

Conditions traffic networks for <strong>the</strong> study area during <strong>the</strong> morning and evening<br />

peak hours. The networks were balanced to eliminate discrepancies due to<br />

differences in peak hours for individual locations. The study area’s overall peak<br />

hours were determined to occur between 7:45 AM and 8:45 AM and between<br />

4:45 PM and 5:45 PM. Existing Condition (2006) morning and evening peak<br />

hour traffic volumes are presented in Figures 9-3 and 9-4, respectively. Detailed<br />

data collection summary sheets for ATRs and TMCs are included in <strong>the</strong><br />

Transportation Appendix.<br />

9.0 Transportation Access Plan 9-14


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 9-3 2006 Existing Conditions: Morning Peak Hour Traffic Volumes<br />

Figure 9-4 2006 Existing Conditions: Evening Peak Hour Traffic Volumes<br />

9.0 Transportation Access Plan 9-15


9.2.4 Parking<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

This section identifies <strong>the</strong> existing parking supply and demand in <strong>the</strong> study area,<br />

which comprises on-street parking that is largely unrestricted. Although <strong>the</strong>re is<br />

off-street parking on <strong>the</strong> existing project site and o<strong>the</strong>r sites in <strong>the</strong> vicinity, <strong>the</strong>re<br />

are no off-street public parking facilities.<br />

On-street parking located in <strong>the</strong> area around <strong>the</strong> project site is summarized in<br />

Table 9-2 and illustrated in Figure 9-5. There are approximately 117 on-street<br />

spaces in <strong>the</strong> defined study area. 107 of <strong>the</strong> 117 spaces are unrestricted parking<br />

and <strong>the</strong> remaining 10 spaces are ei<strong>the</strong>r for South <strong>Boston</strong> Residents between 6:00<br />

PM and 10:00 AM Monday-Friday (2 spaces) or for South <strong>Boston</strong> Visitors<br />

between 6:00 PM and 10:00 AM Monday-Friday (8 spaces). Mid-day and<br />

overnight observations revealed that, on average, 54% and 58% of <strong>the</strong> on-street<br />

spaces were used, respectively, although parking is very under-utilized on East<br />

First Street and West First Street.<br />

Table 9-2 On-Street Parking Summary<br />

Street Location (Both Sides of Street) Restricted Un-Restricted Mid Day<br />

Utilization<br />

East First Street West First Street to H Street - 27 7% 7%<br />

East Second Street Dorchester Street to H Street 10 14 92% 88%<br />

West First Street East First Street to Dorchester Street - 24 25% 33%<br />

Dorchester Street East First Street to East Second Street - 24 75% 79%<br />

9.0 Transportation Access Plan 9-16<br />

Overnight<br />

Utilization<br />

H Street East First Street to East Second Street - 19 84% 100%<br />

Total 10 107 54% 58%<br />

Source: Vanasse Hangen Brustlin, Inc. field survey conducted August 2, 2006.


Figure 9-5 Parking - Existing Curb Use<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

9.0 Transportation Access Plan 9-17


9.2.5 Crash History<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

In order to identify any traffic safety concerns in <strong>the</strong> study area, crash data for <strong>the</strong><br />

study area intersections was obtained from <strong>the</strong> Massachusetts Highway<br />

Department (MassHighway) for <strong>the</strong> most recent three-year period available<br />

(2002-2004). There were 2 accidents reported at <strong>the</strong> 5 study area intersections<br />

over <strong>the</strong> three-year period 1 .<br />

• In 2003, <strong>the</strong>re was an angle-type crash reported at Dorchester Street and<br />

Second Street. The crash occurred during <strong>the</strong> morning peak period in wet<br />

conditions. The crash resulted in property-related damage.<br />

• In 2003, <strong>the</strong>re was a head-on crash reported at 405 West First Street, near <strong>the</strong><br />

intersection of Dorchester Street/West First Street/East Second Street. The<br />

crash occurred on a weekday during off-peak hours in dry conditions and<br />

resulted in personal injury.<br />

As <strong>the</strong> crash history is very limited, it is not possible to identify any specific crash<br />

trends or safety issues.<br />

9.2.6 Pedestrian and Bicycle Conditions<br />

Pedestrian activities were observed and recorded at each of <strong>the</strong> study area<br />

intersections during morning and evening peak hours. The following sections<br />

discuss pedestrian facilities and peak hour pedestrian flows in <strong>the</strong> study area.<br />

Existing Pedestrian and Bicycle Facilities<br />

Pedestrian facilities in <strong>the</strong> study area include sidewalks that vary in width from<br />

less than four feet to as much as eleven feet. Figure 9-6 provides an inventory of<br />

existing sidewalks and <strong>the</strong>ir minimum widths (shown in feet). There are no<br />

1 Accidents at parking lot driveways were not analyzed because accident locations are rarely reported with a<br />

high enough level of precision to identify accidents at specific driveways.<br />

9.0 Transportation Access Plan 9-18


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

marked crosswalks at study area intersections. Sidewalk conditions vary from<br />

street to street.<br />

Figure 9-6 Existing Sidewalk Widths<br />

9.0 Transportation Access Plan 9-19


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Along <strong>the</strong> north side of East First Street, <strong>the</strong>re are only nominal provisions for<br />

pedestrians, with no sidewalk available in some locations to <strong>the</strong> west adjacent to<br />

<strong>the</strong> Casey & Hayes property. Sidewalks surrounding <strong>the</strong> 3 Dorchester Street<br />

project site vary from new sidewalks along Dorchester Street to no sidewalks<br />

provided near <strong>the</strong> northwest corner of <strong>the</strong> block. Surrounding <strong>the</strong> project site,<br />

sidewalk conditions also vary from new concrete sidewalks along Dorchester<br />

Street that are ADA-accessible to narrower sidewalks on East First Street, with<br />

obstructions, that are not accessible.<br />

Bicycle facilities in <strong>the</strong> study area are minimal, with no visible on-street bicycle<br />

racks and no marked bicycle lanes along any of <strong>the</strong> study area roadways.<br />

Pedestrian Volumes<br />

Morning and evening peak hour pedestrian counts were conducted at each of <strong>the</strong><br />

study area intersections and are presented in Figures 9-7 and 9-8, respectively.<br />

The following key observations characterize pedestrian activities in <strong>the</strong> project<br />

study area:<br />

• Pedestrian volumes are generally very low in <strong>the</strong> study area. Along East First<br />

Street, pedestrians were observed walking along both sides of <strong>the</strong> street,<br />

including <strong>the</strong> north side of <strong>the</strong> street where <strong>the</strong>re is a minimal sidewalk with<br />

obstacles.<br />

• The intersection with <strong>the</strong> highest pedestrian volume is West First Street/East<br />

Second Street/Dorchester Street. At this intersection, <strong>the</strong>re were a total of 52<br />

pedestrians in <strong>the</strong> morning peak. In <strong>the</strong> evening peak hour, this intersection<br />

also was <strong>the</strong> busiest in <strong>the</strong> study area, with a total of 21 pedestrians observed<br />

crossing <strong>the</strong> street.<br />

9.0 Transportation Access Plan 9-20


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 9-7 Existing Conditions Morning Peak Hour Pedestrian Volumes<br />

Figure 9-8 Existing Conditions Evening Peak Hour Pedestrian Volumes<br />

9.0 Transportation Access Plan 9-21


9.2.7 Public Transportation<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The project site is located within a 5-minute (1/4-mile) walk of three<br />

Massachusetts Bay Transportation <strong>Authority</strong> (MBTA) bus routes, within 1/3-mile<br />

of <strong>the</strong> Silver Line and Route 7 and about 1-mile from <strong>the</strong> MBTA’s Broadway<br />

Station on <strong>the</strong> Red Line rapid transit line. Bus service to Broadway Station takes<br />

less than 10 minutes, with Red Line service to downtown in about 10 minutes.<br />

Bus service to Back Bay is also directly provided by two bus routes, with service<br />

taking about 30 minutes. These routes are described in detail below, and are<br />

shown in Figure 9-9. MBTA bus routes are accessible to persons with<br />

disabilities.<br />

Route 5<br />

MBTA bus route 5 provides service from City Point in South <strong>Boston</strong> to<br />

McCormack Housing via Broadway, Dorchester Street, Andrew Square Station<br />

and Columbia Road. The nearest bus stop is at <strong>the</strong> intersection of H Street and<br />

East Broadway, about 1/8-mile from <strong>the</strong> project site. Route 5 service runs from<br />

8:45 AM until 3:00 PM inbound, from 9:15 AM until 2:30 PM outbound<br />

approximately every hour during weekdays. Saturday inbound service operates<br />

from 9:45 AM until 3:00 PM approximately every hour. Saturday outbound<br />

service operates from 9:15 AM until 2:30 PM approximately every hour. There is<br />

no Sunday service.<br />

Route 7<br />

Route 7 provides service from downtown crossing in <strong>Boston</strong> to City Point in<br />

South <strong>Boston</strong> via Summer Street / L Street and East Broadway. The nearest bus<br />

stop is at <strong>the</strong> intersection of East First Street and Summer Street, about 1/3-mile<br />

from <strong>the</strong> project site. Route 7 service runs from 5:15 AM to 10:00 PM inbound,<br />

5:40 AM to 10:40 PM outbound during <strong>the</strong> week; 5:15 AM to 9:50 PM inbound<br />

and 5:37 AM to 10:20 PM outbound on Saturday; and no service on Sunday.<br />

9.0 Transportation Access Plan 9-22


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

During <strong>the</strong> morning and evening peak hours, every o<strong>the</strong>r outbound (morning) and<br />

inbound (evening) trip operates via <strong>the</strong> Harbor Industrial Park along Pappas Way<br />

and East First Street adjacent <strong>the</strong> project site.<br />

Figure 9-9 MBTA Transit Map<br />

Route 9<br />

Route 9 provides service from City Point in South <strong>Boston</strong> to Copley Square in <strong>the</strong><br />

Back Bay via Broadway, West Broadway, Broadway Station, East Berkeley<br />

9.0 Transportation Access Plan 9-23


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Street, St. James Avenue and Boylston Street. The nearest bus stop is at <strong>the</strong><br />

intersection of H Street and East Broadway, about 1/8-mile from <strong>the</strong> project site.<br />

Route 9 service runs from 5:13 AM to 12:28 AM inbound, 5:38 AM to 12:52 AM<br />

outbound during <strong>the</strong> week; 5:10 AM to 12:30 AM inbound and 5:40 AM to 12:54<br />

AM outbound on Saturday; and 6:00 AM to 12:30 AM inbound and 6:25 AM to<br />

12:53 AM on Sunday.<br />

Route 10<br />

Route 10 provides service from City Point in South <strong>Boston</strong> to Copley Square in<br />

<strong>the</strong> Back Bay via Broadway, Dorchester Street, Andrew Station, Southampton<br />

Street, Newmarket Square, Massachusetts Avenue, Albany Street, East Newton<br />

Street/East Concord Street, Washington Street, West Dedham Street and<br />

Dartmouth Street. The nearest bus stop is at <strong>the</strong> intersection of H Street and East<br />

Broadway, about 1/8-mile from <strong>the</strong> project site. Route 10 service runs from 4:55<br />

AM to 12:32 AM inbound, 5:30 AM to 1:05 AM outbound during <strong>the</strong> week; 6:15<br />

AM to 12:20 AM inbound and 7:00 AM to 12:50 AM outbound on Saturday; and<br />

6:00 AM to 12:15 AM inbound and 6:28 AM to 12:45 AM on Sunday.<br />

Silver Line SL3<br />

The MBTA’s new Silver Line Bus Rapid Transit provides service from City Point<br />

in South <strong>Boston</strong> to South Station in downtown <strong>Boston</strong>, via <strong>the</strong> South <strong>Boston</strong><br />

Waterfront and providing an important link to Logan International Airport via <strong>the</strong><br />

SL1 transfer at <strong>the</strong> Silver Line Way Station. The nearest bus stop is at <strong>the</strong><br />

intersection of East First Street and Summer Street, about 1/3-mile from <strong>the</strong><br />

project site. SL3 service runs from 6:03 AM to 8:18 PM inbound, 5:45 AM to<br />

7:55 PM outbound during <strong>the</strong> week. There is no weekend SL3 service. The<br />

MBTA’s Silver Line is accessible to persons with disabilities.<br />

Red Line<br />

The nearest MBTA rapid transit station is located on <strong>the</strong> Red Line at <strong>the</strong><br />

Broadway Station. The Red Line is <strong>the</strong> MBTA’s busiest rapid transit line,<br />

9.0 Transportation Access Plan 9-24


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

providing service from Braintree on <strong>the</strong> South Shore, Ashmont/Mattapan in<br />

Dorchester, downtown <strong>Boston</strong>, and major academic and employment centers in<br />

Cambridge. The Red Line provides service from 5:05 AM until 1:08 AM<br />

northbound and between 5:24 AM until 12:15 AM southbound Monday-Saturday;<br />

from 5:50 AM until 1:03 AM northbound and between 6:08 AM until 12:14 AM<br />

southbound on Sunday. The Red Line’s Broadway Station is ADA-accessible.<br />

9.2.8 Vehicular Site Access<br />

Currently, <strong>the</strong> project site has driveway curb cuts in four locations and a loading<br />

dock accessed on East Second Street. There is one driveway curb cut providing<br />

access to <strong>the</strong> Fishbach & Moore loading area, located on Dorchester Street near<br />

its intersection with East First Street. There is an additional driveway curb cut<br />

located on East First Street near <strong>the</strong> intersection with Dorchester Street serving<br />

<strong>the</strong> existing primary surface parking lot. A third driveway curb cut located about<br />

mid-block on East Second Street provides ano<strong>the</strong>r access point to <strong>the</strong> surface<br />

parking lot. A fourth driveway curb cut providing access to <strong>the</strong> existing Fishbach<br />

& Moore surface parking area is located on H Street near <strong>the</strong> corner of East First<br />

Street and H Street. Finally, a small loading dock is located on East Second<br />

Street attached to <strong>the</strong> Distillery Building, near <strong>the</strong> midpoint of <strong>the</strong> building on<br />

East Second Street.<br />

9.2.9 Adjacent Land Uses<br />

The BTD requested that as part of this Expanded PNF an inventory and<br />

description of adjacent land uses be provided to better understand <strong>the</strong> impact of<br />

<strong>the</strong> project on loading activity of abutting properties. Adjacent uses and driveway<br />

curb cuts are shown in Figure 9-10.<br />

Industrial uses are located across East First Street to <strong>the</strong> north and H Street to <strong>the</strong><br />

east. There are two driveway curb cuts located on East First Street at <strong>the</strong><br />

intersections of Dorchester Street and H Street. Observations during <strong>the</strong> morning<br />

peak hour revealed numerous trucks exiting <strong>the</strong> Casey & Hayes property at <strong>the</strong> H<br />

9.0 Transportation Access Plan 9-25


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Street driveway, turning westbound onto East First Street. Along H Street, <strong>the</strong>re<br />

are four curb cuts across <strong>the</strong> street from <strong>the</strong> project site, but it appears that only<br />

one driveway is in active use, as <strong>the</strong> fence was locked at <strong>the</strong> remaining three<br />

driveways and vehicles were parked blocking access to <strong>the</strong>se driveways on both<br />

sides of <strong>the</strong> fence.<br />

Figure 9-10 Adjacent Uses, Access Points, Curb Cuts<br />

9.0 Transportation Access Plan 9-26


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

To <strong>the</strong> south, <strong>the</strong>re are light industrial uses at both <strong>the</strong> corner of East Second<br />

Street and H Street and Dorchester Street. Mid-block along East Second Street<br />

between Dorchester Street and H Street are residential uses. There are numerous<br />

curb cuts on <strong>the</strong> south side of East Second Street, primarily serving <strong>the</strong> large<br />

driveways to <strong>the</strong> industrial uses. The residences have two driveway curb cuts.<br />

Finally, across Dorchester Street is <strong>the</strong> newly constructed 3 Dorchester Street<br />

project, a residential development. There are no driveway curb cuts for <strong>the</strong> 3<br />

Dorchester Street project on Dorchester Street.<br />

9.3 EVALUATION OF FUTURE TRANSPORTATION CONDITIONS<br />

To evaluate future roadway operations, traffic volumes in <strong>the</strong> study area were<br />

projected to <strong>the</strong> year 2011 to reflect a five-year planning horizon. The 2011 No-<br />

Build traffic volumes include all existing traffic, new traffic attributable to general<br />

background growth, and traffic generated by identified planned/approved<br />

developments in <strong>the</strong> area. Anticipated site-generated traffic volumes that are<br />

expected to be generated by <strong>the</strong> project were <strong>the</strong>n added to <strong>the</strong> No-Build traffic<br />

volumes to provide Build traffic volumes. In addition, any roadway<br />

improvements currently under construction or planned to be completed within <strong>the</strong><br />

planning horizon are taken into account when analyzing both future No-Build and<br />

Build Conditions.<br />

9.3.1 2011 No Build Condition<br />

The 2011 No Build Condition considers study area traffic conditions if <strong>the</strong><br />

Distillery project was not built. 2011 No Build Condition traffic volumes were<br />

developed by considering background traffic growth and traffic related to specific<br />

development by o<strong>the</strong>rs expected to be completed by <strong>the</strong> 2011 analysis year.<br />

9.0 Transportation Access Plan 9-27


Background Growth<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

In consultation with <strong>the</strong> BTD, <strong>the</strong> No Build Conditions for study area<br />

intersections were developed by applying a 1% per year background traffic<br />

growth rate to <strong>the</strong> 2006 Existing Condition traffic volumes.<br />

Specific Area Developments<br />

There are two developments expected to influence traffic volumes within <strong>the</strong><br />

study area - <strong>the</strong> 3 Dorchester Street project and <strong>the</strong> Channel Wharf Project.<br />

Traffic volumes from <strong>the</strong>se projects were obtained from <strong>the</strong> Channel Wharf Draft<br />

Project Impact Report prepared by Daylor Consulting Group in 2002. Since <strong>the</strong><br />

filing of <strong>the</strong> Channel Wharf DPIR, a portion of <strong>the</strong> 3 Dorchester Street project has<br />

been completed. Thus, some traffic related to this project is included in <strong>the</strong> traffic<br />

counts conducted for <strong>the</strong> Distillery Project. However, <strong>the</strong> entire 3 Dorchester<br />

Street project, as represented in <strong>the</strong> Channel Wharf DPIR, was added to <strong>the</strong> 2011<br />

projections, representing a more conservative analysis. The resulting 2011 No-<br />

Build morning and evening peak hour traffic volumes are presented in Figures 9-<br />

11 and 9-12.<br />

Figure 9-11 2011 No-Build Condition Morning Peak Hour Traffic Volume<br />

9.0 Transportation Access Plan 9-28


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 9-12 2011 No-Build Condition Evening Peak Hour Traffic Volume<br />

9.3.2 2011 Build Condition<br />

2011 Build Condition traffic volumes for <strong>the</strong> study area intersections were<br />

determined by estimating site-generated traffic volumes and distributing <strong>the</strong>se<br />

volumes over <strong>the</strong> study area roadways. The site-generated volumes were <strong>the</strong>n<br />

added to <strong>the</strong> 2011 No-Build traffic volumes to create <strong>the</strong> Build volume networks.<br />

The following section describes <strong>the</strong> procedure used to estimate site-generated<br />

traffic.<br />

Project-Generated Trips and Mode Split<br />

The Distillery project will contain a mix of uses designed to enhance and blend in<br />

with <strong>the</strong> existing surrounding neighborhood. Trip generation was developed for<br />

each new component of <strong>the</strong> project independently, based on <strong>the</strong> proposed program<br />

listed on page 9-3 (also in Table 2-4) that was current at <strong>the</strong> time of analysis.<br />

9.0 Transportation Access Plan 9-29


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The analysis presented in this section is conservative in that it does not take any<br />

credit for <strong>the</strong> elimination of some of <strong>the</strong> existing uses on <strong>the</strong> site, and does not<br />

reflect <strong>the</strong> fact that some trips generated by individual project components will be<br />

shared (e.g. residential – retail or café).<br />

The ITE Trip Generation Manual 2 provides trip generation rates for much of <strong>the</strong><br />

proposed project, including <strong>the</strong> residential (ITE Land Use Code 230 – Residential<br />

Condominium/Townhouse), retail (Land Use Code 852 - Convenience Market)<br />

and café (Land Use Code 933) portion of <strong>the</strong> project. While trip generation rates<br />

for artists’ workshops, galleries and greenhouses are not specifically defined by<br />

ITE, Land Use Code 110, General Light Industrial 3 , provides an appropriate<br />

proxy for <strong>the</strong> level of trips that will be generated by those project components.<br />

Special events held at <strong>the</strong> two galleries may produce additional trips, but <strong>the</strong>se<br />

events would likely occur during off-peak hours and would not affect <strong>the</strong> peak<br />

hour analysis. The trip generation for each of <strong>the</strong> Land Use Codes is provided in<br />

<strong>the</strong> Transportation Appendix.<br />

Table 9-3 provides <strong>the</strong> daily and peak hour person-trip generation estimates for<br />

<strong>the</strong> proposed project, using a vehicle-occupancy rate (VOR) of 1.2 in order to<br />

convert <strong>the</strong> raw ITE vehicle trip generation estimates to person trips. It should be<br />

noted that <strong>the</strong> residential trip rates were applied to <strong>the</strong> 69 new residential units (44<br />

residential and 25 live-work) in <strong>the</strong> proposed project, as <strong>the</strong> 30 existing live/work<br />

units will remain, and are already accounted for in <strong>the</strong> base traffic counts.<br />

2 Institute of Transportation Engineers Trip Generation 7th Edition<br />

3 ITE LUC 110, General Light Industrial, is defined as having fewer than 500 employees, “an emphasis on<br />

activities o<strong>the</strong>r than manufacturing and typically have minimal office space. Typical light industrial<br />

activities include printing, material testing and assembly of data processing equipment.” Institute of<br />

Transportation Engineers Trip Generation 7th Edition, page 89<br />

9.0 Transportation Access Plan 9-30


Morning Peak Hour<br />

Table 9-3: Person Trip Generation Summary<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Residential Galleries 1 Retail Café Total VOR Person Trips<br />

In 7 10 24 62 103 1.2 124<br />

Out 37 8 23 62 130 1.2 156<br />

Total 44 18 47 124 233 1.2 280<br />

Evening Peak Hour<br />

In 34 9 26 24 93 1.2 112<br />

Out 17 11 27 24 79 1.2 95<br />

Total 51 20 53 48 172 1.2 207<br />

Weekday Daily<br />

In 260 12 695 608 1,575 1.2 1,890<br />

Out 260 12 695 608 1,575 1.2 1,890<br />

Total 520 24 1,390 1,216 3,150 1.2 3,780<br />

1 Includes <strong>the</strong> two galleries and <strong>the</strong> greenhouse<br />

Source: Institute of Transportation Engineers Trip Generation 7th Edition<br />

Trip generation estimates are generally based on data ga<strong>the</strong>red at auto-oriented<br />

suburban locations, and an adjustment must be made for <strong>the</strong> mix of transportation<br />

options available in <strong>the</strong> South <strong>Boston</strong> neighborhood, including transit, walking<br />

and bicycling. Mode share data for <strong>the</strong> South <strong>Boston</strong> neighborhood was obtained<br />

from <strong>the</strong> BTD and analyzed separately by daily, morning and evening periods.<br />

The mode splits are presented in Table 9-4.<br />

9.0 Transportation Access Plan 9-31


Table 9-4: Mode Share<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

AM PM<br />

Mode Daily In Out In Out<br />

Automobile 52% 35% 58% 58% 35%<br />

Transit 15% 22% 13% 13% 22%<br />

Walk/Bike/O<strong>the</strong>r 33% 43% 29% 29% 43%<br />

Total 100% 100% 100% 100% 100%<br />

Source: <strong>Boston</strong> Transportation Department Mode Share for Zone 13<br />

These mode shares were applied to <strong>the</strong> person trip generation results in order to<br />

obtain vehicle trips, transit trips and pedestrian/bicycle trips. The auto mode split<br />

includes all vehicle-based trips including taxis and has been adjusted by a vehicle<br />

occupancy rate of 1.2. This VOR is consistent with previous studies in <strong>the</strong> South<br />

<strong>Boston</strong> area. Vehicle, transit and pedestrian trips are shown in Table 9-5 below.<br />

9.0 Transportation Access Plan 9-32


Table 9-5: Trip Generation by Mode Summary<br />

Morning Peak<br />

Hour<br />

In<br />

Out<br />

Total<br />

Evening Peak<br />

Hour<br />

In<br />

Out<br />

Total<br />

Weekday Daily<br />

In<br />

Out<br />

Total<br />

Vehicle/<br />

Person Trips<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

VOR<br />

9.0 Transportation Access Plan 9-33<br />

Vehicle<br />

Trips<br />

Transit Trips Pedestrian Trips<br />

124 1.2 36 27 53<br />

156 1.2 75 20 45<br />

280 1.2 111 47 98<br />

112 1.2 53 14 32<br />

95 1.2 28 21 41<br />

207 1.2 81 35 73<br />

1,890 1.2 819 283 623<br />

1,890 1.2 819 283 623<br />

3,780 1.2 1,638 566 1,246<br />

As shown in Table 9-5, <strong>the</strong> Distillery project is expected to generate<br />

approximately 111 new vehicle trips (36 in, 75 out) during <strong>the</strong> weekday morning<br />

peak hour, and 81 new vehicle trips (53 in, 28 out) during <strong>the</strong> weekday evening<br />

peak hour.<br />

During <strong>the</strong> morning peak hour, <strong>the</strong> project is expected to generate approximately<br />

47 new transit trips (27 in, 20 out) and 98 pedestrian trips (53 in and 45 out), and<br />

35 new transit trips (14 in, 21 out) and 73 pedestrian trips (32 in, 41 out) during<br />

<strong>the</strong> weekday evening peak hour.<br />

The trip generation estimates presented above did not take into account <strong>the</strong><br />

reduction in trips due to <strong>the</strong> demolition of <strong>the</strong> existing 19,680 square-foot Bottling<br />

Plant and 3,524 square-foot Cooper’s Shop buildings. Additionally, no pass-by or<br />

internal trip reduction was assumed. In particular, <strong>the</strong> café and convenience retail<br />

is expected to have a large portion of trips resulting from passers-by or shared<br />

(internal) trips, so <strong>the</strong> analysis presented presents a more conservative scenario.


Trip Distribution<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The BTD provided trip distribution patterns for <strong>the</strong> neighborhood that <strong>the</strong><br />

Distillery project is located in (Zone 13), and <strong>the</strong>se were reduced to a general<br />

distribution to/from <strong>the</strong> Distillery site. The BTD’s trip distribution patterns are<br />

derived from home-based, work-based and “o<strong>the</strong>r” trip categories, accurately<br />

reflecting <strong>the</strong> mixed-use nature of <strong>the</strong> Distillery project. The distribution pattern<br />

developed and approved by <strong>the</strong> BTD for this project was also compared to that<br />

presented in <strong>the</strong> Channel Wharf DPIR. Table 9-6 and Figure 9-13 present <strong>the</strong><br />

anticipated trip distribution patterns for <strong>the</strong> proposed project.<br />

Table 9-6: Trip Distribution<br />

Origin Travel Route Traffic Assigned to Route<br />

North/West via West First Street 48%<br />

South via Dorchester Street 41%<br />

Local via East First/Second Streets 11%<br />

Total 100%<br />

Source: BTD<br />

As shown, <strong>the</strong> majority of vehicle trips will utilize West First Street and<br />

Dorchester Street to access points north, west and south of <strong>the</strong> site. The greatest<br />

increase in traffic will be on H Street, with an additional 38 vehicles and 36<br />

vehicles on East First Street in <strong>the</strong> morning peak hour.<br />

9.0 Transportation Access Plan 9-34


Figure 9-13 Project Trip Distribution<br />

Build Traffic Volumes<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Trips were assigned to <strong>the</strong> proposed site driveways based on <strong>the</strong> distribution of<br />

parking spaces served by each driveway. The site-generated traffic volumes were<br />

assigned to <strong>the</strong> study area roadways according to <strong>the</strong> trip distribution and travel<br />

patterns presented in Table 9-6 for <strong>the</strong> morning and evening peak hours. The<br />

project trips are shown graphically in Figures 9-14 and 9-15. Site-generated<br />

traffic was <strong>the</strong>n combined with <strong>the</strong> 2011 No-Build traffic volumes to develop <strong>the</strong><br />

2011 Build traffic volumes. The resulting 2011 Build Condition morning and<br />

evening peak hour traffic volumes are presented in Figures 9-16 and 9-17.<br />

9.0 Transportation Access Plan 9-35


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 9-14 Project Generated Trips Morning Peak Hour Traffic Volumes<br />

Figure 9-15 Project Generated Trips Evening Peak Hour Traffic Volumes<br />

9.0 Transportation Access Plan 9-36


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 9-16 2011 Build condition Morning Peak Hour Traffic Volumes<br />

Figure 9-17 2011 Build condition Evening Peak Hour Traffic Volumes<br />

9.0 Transportation Access Plan 9-37


Pedestrians<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

As presented in Table 9-5, <strong>the</strong> project is expected to generate 98 (73) pedestrian<br />

trips in <strong>the</strong> morning (evening) peak hour, and a total of 1,246 pedestrian trips<br />

during a typical weekday. These pedestrians are expected to generally walk along<br />

<strong>the</strong> south side of East First Street, Dorchester Street, H Street and East Second<br />

Street to access <strong>the</strong> local neighborhood and MBTA services on Broadway and at<br />

L Street. Sidewalk provision in most locations is adequate, with <strong>the</strong> exception of<br />

parts of East First Street and on <strong>the</strong> east side of H Street. However, as part of <strong>the</strong><br />

project, <strong>the</strong> sidewalk adjacent to <strong>the</strong> site on East First Street will be reconstructed<br />

and widened to 5’6”.<br />

Parking<br />

The project proposes 123 parking spaces for residents, workers and visitors.<br />

These spaces are distributed as follows: 99 spaces are to be allocated to <strong>the</strong><br />

residential units on site (including 30 existing Distillery building units plus 69<br />

new units) and 24 spaces are to be allocated to <strong>the</strong> galleries, café, and retail space<br />

(including existing commercial space in <strong>the</strong> Distillery, a total of 7,221 + 31,812 =<br />

39,033 nsf). The parking ratios are 1.0 space per residential unit and less than 1<br />

per 1,000 square feet of commercial/retail space. It is anticipated that <strong>the</strong>se<br />

spaces, combined with <strong>the</strong> travel demand management measures described in <strong>the</strong><br />

next section, will be sufficient to serve all users on-site.<br />

Public Transportation<br />

The proposed project is expected to generate approximately 566 transit trips per<br />

weekday, with 47 of those trips occurring during <strong>the</strong> morning peak hour and 35<br />

during <strong>the</strong> evening peak hour. These trips are expected to be distributed amongst<br />

<strong>the</strong> areas bus routes and <strong>the</strong> Red Line with no undue impact. The Proponent will<br />

work with <strong>the</strong> MBTA to fur<strong>the</strong>r enhance service near <strong>the</strong> project site.<br />

9.0 Transportation Access Plan 9-38


9.4 TRAFFIC OPERATIONS ANALYSIS<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Level of service (LOS) is <strong>the</strong> term used to denote <strong>the</strong> different operating<br />

conditions that occur on a given roadway or intersection under various volume<br />

loads. It is a qualitative measure of <strong>the</strong> effect of roadway/intersection geometry,<br />

speed, travel delay, freedom to maneuver, and safety. Level of service provides an<br />

index to <strong>the</strong> operational qualities of a roadway or intersection. LOS designations<br />

range from A to F, with LOS A representing <strong>the</strong> best operating conditions and<br />

LOS F representing <strong>the</strong> worst operating conditions.<br />

Highway Capacity Manual (HCM) evaluation criteria are different for signalized<br />

and for unsignalized intersections. For signalized intersections, level of service is<br />

calculated for individual moves or combination of moves, approaches and for <strong>the</strong><br />

overall intersection. For unsignalized intersections, as is <strong>the</strong> case for all of <strong>the</strong><br />

study intersections, only <strong>the</strong> critical moves are analyzed, i.e. <strong>the</strong> minor street<br />

movements and/or <strong>the</strong> left turn movements from <strong>the</strong> major street.<br />

A level of service analysis was performed at study intersections during <strong>the</strong><br />

morning and evening peak hours for each scenario. Table 9-7 shows 2006<br />

Existing, 2011 No Build and 2011 Build morning peak hour intersection LOS for<br />

<strong>the</strong> study area for unsignalized intersections. Table 9-8 shows 2006 Existing,<br />

2011 No Build and 2011 Build evening peak hour intersection LOS for <strong>the</strong> study<br />

area for all intersections. Complete Synchro 6 reports are provided in <strong>the</strong><br />

Transportation Appendix.<br />

It should be noted that for <strong>the</strong> West First Street/East First Street/Pappas Way<br />

intersection it is necessary to perform <strong>the</strong> analysis as two separate intersections, as<br />

follows:<br />

1. West First Street/East First Street<br />

1A. East First Street/Pappas Way<br />

9.0 Transportation Access Plan 9-39


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

As shown in Tables 9-7 and 9-8, all study area intersections operate at Level of<br />

Service (LOS) C or better during both morning and evening peak hours, and are<br />

expected to continue to do so under future No Build conditions with only minor<br />

increases in delay for critical movements.<br />

9.0 Transportation Access Plan 9-40


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Table 9-7 Unsignalized Intersection Capacity Analysis Summary<br />

Weekday Morning Peak Hour<br />

2006 Existing<br />

2011 No-Build 2011 Build Condition<br />

Condition<br />

Condition<br />

Location Approach v/c 1 Delay2 LOS3 v/c 1 Delay2 LOS3 v/c<br />

1<br />

Delay2 LOS3 1. East First Street/ West First<br />

Street<br />

2. East First Street/ Dorchester<br />

Street<br />

Westbound<br />

Southbound<br />

Northbound<br />

Eastbound<br />

Westbound<br />

Northbound<br />

Southbound<br />

3. East First Street/ H Street Eastbound<br />

Westbound<br />

Northbound<br />

Southbound<br />

4. West First Street/ East Second<br />

Street/ Dorchester Street<br />

Westbound<br />

Eastbound<br />

Northbound<br />

Southbound<br />

5. East Second Street/H Street Eastbound<br />

Westbound<br />

Northbound<br />

1A. East First Street/ Pappas Way Eastbound<br />

Westbound<br />

Southbound<br />

Site Drive A/ Dorchester Street Westbound<br />

Northbound<br />

Southbound<br />

Site Drive B/ H Street Eastbound<br />

Northbound<br />

0.08<br />

0.11<br />

0.28<br />

0.00<br />

0.03<br />

0.12<br />

0.00<br />

0.00<br />

0.17<br />

0.16<br />

0.01<br />

0.17<br />

0.19<br />

0.08<br />

0.00<br />

0.01<br />

0.05<br />

0.12<br />

0.32<br />

0.48<br />

0.06<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

3<br />

NEG<br />

15<br />

NEG<br />

1<br />

11<br />

NEG<br />

NEG<br />

NEG<br />

12<br />

11<br />

16<br />

11<br />

4<br />

NEG<br />

2<br />

NEG<br />

10<br />

9.0 Transportation Access Plan 9-41<br />

11<br />

12<br />

9<br />

N/A<br />

N/A<br />

N/A<br />

A<br />

A<br />

B<br />

A<br />

A<br />

B<br />

A<br />

A<br />

A<br />

B<br />

B<br />

C<br />

B<br />

A<br />

A<br />

A<br />

A<br />

B<br />

B<br />

B<br />

A<br />

N/A<br />

N/A<br />

N/A<br />

0.09<br />

0.12<br />

0.43<br />

0.00<br />

0.03<br />

0.15<br />

0.00<br />

0.00<br />

0.18<br />

0.17<br />

0.01<br />

0.20<br />

0.22<br />

0.09<br />

0.00<br />

0.01<br />

0.05<br />

0.12<br />

0.36<br />

0.58<br />

0.07<br />

N/A<br />

N/A<br />

N/A<br />

3<br />

NEG<br />

19<br />

NEG<br />

1<br />

12<br />

NEG<br />

NEG<br />

NEG<br />

13<br />

11<br />

18<br />

11<br />

4<br />

NEG<br />

2<br />

NEG<br />

10<br />

1 Demand of critical movement from <strong>the</strong> minor street or left-turn movement from <strong>the</strong> major street, expressed in vehicles per<br />

hour.<br />

2 Average delay to critical movements, expressed in seconds per vehicle.<br />

3 Level of Service.<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

11<br />

14<br />

9<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

A<br />

A<br />

C<br />

A<br />

A<br />

B<br />

A<br />

A<br />

A<br />

B<br />

B<br />

C<br />

B<br />

A<br />

A<br />

A<br />

A<br />

B<br />

B<br />

B<br />

A<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

0.09<br />

0.13<br />

0.45<br />

0.00<br />

0.04<br />

0.21<br />

0.00<br />

0.00<br />

0.18<br />

0.29<br />

0.01<br />

0.25<br />

0.28<br />

0.09<br />

0.01<br />

0.03<br />

0.05<br />

0.16<br />

0.38<br />

0.65<br />

0.07<br />

0.03<br />

0.06<br />

0.01<br />

0.05<br />

0.01<br />

3<br />

NEG<br />

20<br />

NEG<br />

2<br />

14<br />

NEG<br />

NEG<br />

NEG<br />

15<br />

12<br />

22<br />

13<br />

4<br />

NEG<br />

4<br />

NEG<br />

12<br />

12<br />

17<br />

10<br />

9<br />

NEG<br />

1<br />

9<br />

2<br />

A<br />

A<br />

C<br />

A<br />

A<br />

B<br />

A<br />

A<br />

A<br />

B<br />

B<br />

C<br />

B<br />

A<br />

A<br />

A<br />

A<br />

B<br />

B<br />

C<br />

A<br />

A<br />

A<br />

A<br />

A<br />

A


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Table 9-8 Unsignalized Intersection Capacity Analysis Summary<br />

Weekday Evening Peak Hour<br />

2006 Existing<br />

2011 No-Build 2011 Build Condition<br />

Condition<br />

Condition<br />

Location Approach v/c 1 Delay2 LOS3 v/c 1 Delay2 LOS3 v/c<br />

1<br />

Delay2 LOS3 1. East First Street/ West First<br />

Street<br />

2. East First Street/ Dorchester<br />

Street<br />

Westbound<br />

Southbound<br />

Northbound<br />

Eastbound<br />

Westbound<br />

Northbound<br />

Southbound<br />

3. East First Street/ H Street Eastbound<br />

Westbound<br />

Northbound<br />

Southbound<br />

4. West First Street/ East Second<br />

Street/ Dorchester Street<br />

Westbound<br />

Eastbound<br />

Northbound<br />

Southbound<br />

5. East Second Street/H Street Eastbound<br />

Westbound<br />

Northbound<br />

1A. East First Street/ Pappas Way Eastbound<br />

Westbound<br />

Southbound<br />

Site Drive A/ Dorchester Street Westbound<br />

Northbound<br />

Southbound<br />

Site Drive B/ H Street Eastbound<br />

Northbound<br />

0.10<br />

0.19<br />

0.15<br />

0.00<br />

0.02<br />

0.08<br />

0.00<br />

0.00<br />

0.09<br />

0.08<br />

0.00<br />

0.10<br />

0.31<br />

0.03<br />

0.00<br />

0.01<br />

0.02<br />

0.06<br />

0.29<br />

0.25<br />

0.06<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

4<br />

NEG<br />

11<br />

NEG<br />

2<br />

12<br />

NEG<br />

NEG<br />

NEG<br />

11<br />

9.4<br />

14<br />

11<br />

4<br />

NEG<br />

2<br />

NEG<br />

10<br />

9.0 Transportation Access Plan 9-42<br />

10<br />

9<br />

9<br />

N/A<br />

N/A<br />

N/A<br />

A<br />

A<br />

B<br />

A<br />

A<br />

B<br />

A<br />

A<br />

A<br />

B<br />

A<br />

B<br />

B<br />

A<br />

A<br />

A<br />

A<br />

A<br />

A<br />

A<br />

A<br />

N/A<br />

N/A<br />

N/A<br />

0.10<br />

0.21<br />

0.24<br />

0.00<br />

0.02<br />

0.15<br />

0.00<br />

0.00<br />

0.09<br />

0.09<br />

0.00<br />

0.12<br />

0.34<br />

0.04<br />

0.00<br />

0.01<br />

0.02<br />

0.07<br />

0.33<br />

0.29<br />

0.07<br />

N/A<br />

N/A<br />

N/A<br />

4<br />

NEG<br />

14<br />

NEG<br />

2<br />

13<br />

NEG<br />

NEG<br />

NEG<br />

11<br />

9.5<br />

16<br />

11<br />

4<br />

NEG<br />

2<br />

NEG<br />

10<br />

1 Demand of critical movement from <strong>the</strong> minor street or left-turn movement from <strong>the</strong> major street, expressed in vehicles per<br />

hour.<br />

2 Average delay to critical movements, expressed in seconds per vehicle.<br />

3 Level of Service.<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

10<br />

10<br />

9<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

A<br />

A<br />

B<br />

A<br />

A<br />

B<br />

A<br />

A<br />

A<br />

B<br />

A<br />

C<br />

B<br />

A<br />

A<br />

A<br />

A<br />

A<br />

B<br />

A<br />

A<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

N/A<br />

0.11<br />

0.23<br />

0.25<br />

0.00<br />

0.03<br />

0.19<br />

0.00<br />

0.00<br />

0.09<br />

0.12<br />

0.00<br />

0.16<br />

0.41<br />

0.04<br />

0.00<br />

0.04<br />

0.02<br />

0.09<br />

0.35<br />

0.30<br />

0.07<br />

0.01<br />

0.04<br />

0.01<br />

0.02<br />

0.02<br />

4<br />

NEG<br />

14<br />

NEG<br />

2<br />

14<br />

NEG<br />

NEG<br />

NEG<br />

12<br />

9.7<br />

18<br />

13<br />

4<br />

NEG<br />

4<br />

NEG<br />

11<br />

11<br />

10<br />

9<br />

9<br />

NEG<br />

2<br />

9<br />

3<br />

A<br />

A<br />

B<br />

A<br />

A<br />

B<br />

A<br />

A<br />

A<br />

B<br />

A<br />

C<br />

B<br />

A<br />

A<br />

A<br />

A<br />

B<br />

B<br />

A<br />

A<br />

A<br />

A<br />

A<br />

A<br />

A


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The proposed project is not expected to cause any changes in level of service, and<br />

any increases in delay as a result of <strong>the</strong> project, are limited to a maximum of 4<br />

seconds per vehicle. Generally, <strong>the</strong> increases in delay for each critical move are<br />

in <strong>the</strong> range of 0 to 2 seconds per vehicle. Volume/capacity ratios are very low<br />

under all conditions. Accordingly, <strong>the</strong> study intersections are not expected to be<br />

adversely impacted by <strong>the</strong> proposed project, and will continue to operate well<br />

under future build conditions largely with LOS A or B, and at worst LOS C at a<br />

few approaches. The project driveways are also expected to operate very well at<br />

LOS A in all cases. The SYNCHRO output for all <strong>the</strong> conditions analyzed is<br />

presented in <strong>the</strong> Transportation Appendix.<br />

Again, it should be borne in mind that <strong>the</strong> traffic analysis is conservative in that<br />

no trip credit was taken for <strong>the</strong> elimination of <strong>the</strong> existing Bottling Plant and<br />

Cooper’s Shop, and no shared-trip or pass-by trip credit was assumed.<br />

9.5 ACCESS TO PARKING<br />

9.5.1 Assessment of Alternatives<br />

Taking advantage of <strong>the</strong> natural slope of <strong>the</strong> site from +32 feet at Second Street to<br />

+16.5 feet at <strong>the</strong> junction of First Street and Dorchester Street, <strong>the</strong> parking is<br />

arranged on two levels with a separate access point for each level, obviating <strong>the</strong><br />

need for internal ramps. For each of <strong>the</strong> lower and upper level access points, two<br />

alternative locations were evaluated on <strong>the</strong> following criteria:<br />

• Safety and Function: ease of access and exiting; relative traffic flows at<br />

access point; sight lines; distance from corners.<br />

9.0 Transportation Access Plan 9-43


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

• Nuisance: annunciator noise as disturbance to neighbors; headlights of<br />

exiting vehicles as annoyance to neighbors; interruption to pedestrian flow<br />

at sidewalks.<br />

• Program: <strong>the</strong> effect on parking numbers or o<strong>the</strong>r program elements as a<br />

result of situating <strong>the</strong> access point in one location or ano<strong>the</strong>r.<br />

The analysis of Options 1 and 2 on <strong>the</strong> Lower and upper Levels (LL1 + UL1; LL2<br />

+ UL2) examines alternative options for access as described. The alternative<br />

locations also require changes in <strong>the</strong> assumed grade of <strong>the</strong> parking levels. Option<br />

1 is situated two feet higher than <strong>the</strong> alternative in order to allow level access at<br />

<strong>the</strong> lower level off First Street and to make <strong>the</strong> ramp connection between Second<br />

Street and <strong>the</strong> upper level parking possible. Option 2 is situated two feet lower to<br />

ensure a level connection between Dorchester Street and <strong>the</strong> upper level parking<br />

while at <strong>the</strong> same time keeping a feasible connection between H Street and <strong>the</strong><br />

lower parking level. One general advantage of Option 2 (<strong>the</strong> lower of <strong>the</strong> two<br />

options) is that <strong>the</strong> overall building height is correspondingly lower.<br />

9.5.2 Lower Level Access<br />

Lower Level parking is at +18’ accommodating 57 spaces (LL1) or at +16’<br />

accommodating 62 spaces (LL2). Option LL1 as shown also indicates <strong>the</strong><br />

possibility of adding ano<strong>the</strong>r 42 spaces by double-stacking vehicles (for a Lower<br />

Level total of 99) in <strong>the</strong> basement of <strong>the</strong> Warehouse building. This option is not<br />

financially feasible.<br />

Option LL1 from First Street: this access point is situated midway along <strong>the</strong> First<br />

Street block and is designed for cars entering and leaving <strong>the</strong> lower level at an<br />

elevation of +18 feet. The closest corner is <strong>the</strong> First Street / Dorchester Street<br />

junction, about 70’ away.<br />

9.0 Transportation Access Plan 9-44


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 9-18 Option LL1 Lower Level Access from East First Street<br />

Safety and Function: There are good sightlines in both directions. However, First<br />

Street is <strong>the</strong> most heavily trafficked of all <strong>the</strong> surrounding streets and is a<br />

designated truck route. Westbound traffic in <strong>the</strong> morning is <strong>the</strong> heaviest flow thus<br />

presenting a specific problem for morning traffic exiting <strong>the</strong> Distillery which<br />

would be executing a left turn into <strong>the</strong> flow on <strong>the</strong> far side of <strong>the</strong> road.<br />

Nuisance: First Street is a busy and noisy road with industrial uses on <strong>the</strong> o<strong>the</strong>r<br />

side of <strong>the</strong> road so no additional nuisance is generated by vehicles coming in and<br />

out of <strong>the</strong> site.<br />

Program: Compared to Option LL2 this alternative accommodates five fewer<br />

parking spaces; does not accommodate a truck loading dock; and to make room<br />

for <strong>the</strong> parking spaces <strong>the</strong> mechanical room has to be relocated.<br />

Option LL2 from H Street: this access point is located on H Street at an elevation<br />

of +20 feet, ramping down to +16 feet in <strong>the</strong> parking area. There is also room for<br />

a truck loading dock adjacent.<br />

9.0 Transportation Access Plan 9-45


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 9-19 Option LL2 Lower Level Access from H Street<br />

Safety and Function: The curb cut starts approximately 25 feet from <strong>the</strong> First<br />

Street curb edge. On <strong>the</strong> o<strong>the</strong>r hand H Street is <strong>the</strong> most light trafficked of all <strong>the</strong><br />

streets and it is one way feeding into First Street. Thus for vehicles exiting at this<br />

point <strong>the</strong>re are clear sightlines upstream of <strong>the</strong> traffic (coming downhill from <strong>the</strong><br />

top of H Street) and <strong>the</strong>re are no vehicles turning into H Street from First Street,<br />

rendering <strong>the</strong> shortened view in that direction moot from a safety point of view.<br />

Nuisance: <strong>the</strong> opposite side of H Street between First Street and Second Street is<br />

an industrial use with only one access point. The location of an entrance to <strong>the</strong><br />

parking at this location does not create a nuisance.<br />

Program: <strong>the</strong> location of <strong>the</strong> access at this point allows five more parking spaces<br />

than LL1 and enables <strong>the</strong> conjunction of a loading dock and freight elevator in <strong>the</strong><br />

same location.<br />

9.0 Transportation Access Plan 9-46


9.5.3 Upper Level Access<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Upper Level parking is at + 27’-8” accommodating 45 spaces (UL1) or at +25’<br />

accommodating 66 spaces (UL2).<br />

Option UL1 from Second Street gains access from a street elevation of +32’<br />

ramping down to +27’-8”. The closest corner is Second Street / Dorchester Street,<br />

approximately 80’ away.<br />

Figure 9-20 Option UL1 Upper Level Access from Second Street<br />

Safety and Function: <strong>the</strong> crossroads of Second and Dorchester Streets, both of<br />

which are two-way, is too close in our opinion. In addition, <strong>the</strong> ramp down from<br />

Second Street to <strong>the</strong> parking level presents an additional hazard, particularly for<br />

exiting vehicles which will emerge on a steep slope at <strong>the</strong> same time as having to<br />

look both ways for street traffic.<br />

Nuisance: headlights from emerging traffic will strike <strong>the</strong> opposite side of <strong>the</strong><br />

road which is zoned for residential development. Acceleration noise will be<br />

9.0 Transportation Access Plan 9-47


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

exacerbated on <strong>the</strong> exit slope and braking noise for vehicles accessing <strong>the</strong> garage<br />

will also be a concern.<br />

Program: <strong>the</strong> location of <strong>the</strong> access point on Second Street required <strong>the</strong> raising of<br />

<strong>the</strong> upper level parking to reduce <strong>the</strong> length and slope of <strong>the</strong> access ramp. A<br />

concern is that <strong>the</strong> parking level will be raised so high above street level at <strong>the</strong><br />

lower end of <strong>the</strong> site that <strong>the</strong> overall effect will be that of a formidable wall. In<br />

order to mitigate this effect <strong>the</strong> parking level in option UL1 extends only to <strong>the</strong><br />

corner of Dorchester Street and First Street. In order to make up <strong>the</strong> numbers of<br />

parking spaces this layout demonstrates <strong>the</strong> possibility of double stacking of<br />

vehicles to gain 45 spaces (21 fewer than option UL2). On fur<strong>the</strong>r analysis<br />

mechanical stacking proves to be cost prohibitive both in capital cost and<br />

operations and maintenance.<br />

Option UL2 from Dorchester Street enters <strong>the</strong> upper level parking at +25’ from<br />

street level requiring minimal ramping.<br />

Figure 9-21 Option UL2 Upper Level Access from Dorchester Street<br />

9.0 Transportation Access Plan 9-48


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Safety and Function: <strong>the</strong> access point is approximately 125’ away, a comfortable<br />

distance from <strong>the</strong> two-way junction at Second and Dorchester Streets. Sightlines<br />

are unimpaired and <strong>the</strong> entry is not significantly ramped making negotiation of<br />

both access and exit relatively simple.<br />

Nuisance: while <strong>the</strong> glare of headlights from exiting vehicles may be present,<br />

because <strong>the</strong>re is no significant ramping at this access point lights will be directed<br />

at <strong>the</strong> ground plane ra<strong>the</strong>r than sweeping <strong>the</strong> vertical face of residential<br />

development opposite (as would be <strong>the</strong> case with UL1). In addition any noise of<br />

braking or acceleration will be not significantly worse than that generated in <strong>the</strong><br />

normal course of street traffic.<br />

Program: Option LL2 and UL2 bring <strong>the</strong> parking levels closer to street grades<br />

than do <strong>the</strong> o<strong>the</strong>r options. This allows <strong>the</strong> upper level to extent to First Street to<br />

accommodate 66 spaces, 21 more than Option UL1 and without <strong>the</strong> expense and<br />

difficulty of mechanical parking.<br />

9.5.4 Service Vehicles and Emergency Services<br />

Large Truck Access: as noted above in <strong>the</strong> discussion of LL2, large trucks and<br />

tractor-trailer combinations have access to a loading dock off H Street, offloading<br />

to a freight elevator that services both existing and new buildings. This<br />

means all furniture removal can take place off-street. In addition <strong>the</strong>re is direct<br />

tailboard loading from East Second Street into <strong>the</strong> retail store on <strong>the</strong> corner for<br />

“box trucks” of 14’ length and up to 11 ½’ high. The dock area is 12’ wide<br />

allowing <strong>the</strong> trucks to accommodate <strong>the</strong> wide swing into <strong>the</strong> dock, and <strong>the</strong> trucks<br />

will be completely inside <strong>the</strong> building when unloading, clearing <strong>the</strong> sidewalk.<br />

Small Truck and Van Deliveries: delivery vans have access to <strong>the</strong> upper level<br />

courtyard directly off Second Street. They will have three point turnaround space<br />

on a driveway adjacent to <strong>the</strong> front door of <strong>the</strong> existing Distillery building.<br />

9.0 Transportation Access Plan 9-49


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Emergency Vehicles: emergency services have access to <strong>the</strong> building from all four<br />

surrounding streets and from <strong>the</strong> internal courtyard. A turning circle of radius 41’-<br />

0” is sufficient for full 180-degree turnaround of fire trucks.<br />

9.6 TRANSPORTATION MITIGATION AND IMPROVEMENT PLAN<br />

9.6.1 Project Improvements<br />

This section delineates <strong>the</strong> transportation improvements and enhancement plan<br />

that is proposed to support <strong>the</strong> planned Distillery project. The proponents of <strong>the</strong><br />

Distillery project are dedicated to reducing <strong>the</strong> overall impact of <strong>the</strong> project on <strong>the</strong><br />

surrounding environment, and this extends to <strong>the</strong> transportation impact of <strong>the</strong><br />

project. As such, <strong>the</strong> proponent is studying methods of reducing single-occupant<br />

auto trips to and from <strong>the</strong> site to a greater extent than would be necessary since<br />

<strong>the</strong> project does not generate any adverse impact on area roadways. The purpose<br />

of this transportation improvement plan is to:<br />

• Help alleviate transportation impacts generated by <strong>the</strong> proposed Distillery<br />

project; and<br />

• Provide transportation infrastructure enhancements to <strong>the</strong> surrounding area.<br />

This transportation improvement plan includes several elements:<br />

• Intersection safety improvements;<br />

• Parking management strategies;<br />

• Transportation demand management enhancements;<br />

• Pedestrian access and open space improvements; and<br />

• Construction management actions.<br />

9.0 Transportation Access Plan 9-50


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Table 9-9 lists each transportation improvement element that is proposed and a<br />

summary of <strong>the</strong> purpose and benefit of that action.<br />

Table 9-9 Distillery Project Transportation Improvements and Enhancements<br />

Improvement<br />

Element<br />

Description Purpose/Benefit<br />

1 On-Site Parking Provide up to 123 regular parking spaces on site as part<br />

of <strong>the</strong> project.<br />

2 Pedestrian Access<br />

Improvements<br />

3 Transportation<br />

Demand<br />

Management Actions<br />

Provide new/upgraded sidewalks/crosswalks and street<br />

landscaping to match that on Dorchester Street on H<br />

Street, East First Street and East Second Street<br />

bordering <strong>the</strong> project site.<br />

Provide innovative TDM programs and amenities that<br />

seek to encourage <strong>the</strong> use of car-sharing and transit as a<br />

regular means of commuting.<br />

4 Bicycle Parking Provide bicycle racks, showers, and lockers on-site as<br />

part of <strong>the</strong> project.<br />

5 Prepare<br />

Transportation<br />

Access Plan<br />

Agreement<br />

6 Prepare Construction<br />

Management Plan<br />

Minimizes potential for<br />

parking demand to be<br />

accommodated on street.<br />

Will improve pedestrian<br />

environment for <strong>the</strong><br />

neighborhood.<br />

Will encourage shift in mode<br />

share from auto to transit by<br />

tenants.<br />

Will encourage shift in mode<br />

share from auto to bicycle.<br />

Prepare and submit detailed TAPA to <strong>the</strong> BTD. Will formalize <strong>the</strong><br />

improvement plan and<br />

schedule for implementation.<br />

Prepare and submit detailed Construction Management<br />

Plan.<br />

9.6.2 Transportation Demand Management<br />

Will minimize construction<br />

impacts.<br />

The proponent is considering <strong>the</strong> following Transportation Demand Management<br />

(TDM) strategies for <strong>the</strong> Distillery project:<br />

• Marketing packets including MBTA information<br />

• MBTA Transit Pass subsidies<br />

• Ridematching utilizing an innovative system called Ecolane<br />

• Ridematching through MassRides<br />

9.0 Transportation Access Plan 9-51


• Preferential parking for carpool/vanpools<br />

• Secure, indoor bicycle storage<br />

• Encouraged flextime & staggered work hours<br />

• Compressed work weeks<br />

• Providing bandwidth to allow telecommuting<br />

• Showers for bicyclists<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

• Commuter shuttles to transit, if need is demonstrated, using alternative<br />

fuel vehicles whenever possible<br />

• Providing parking space(s) for car-sharing options, such as Zipcar<br />

• Providing accommodations for plug-in hybrids<br />

The proponent is studying innovative transportation options including <strong>the</strong><br />

following:<br />

Car Sharing<br />

The proponent has had preliminary discussions with Zipcar about supplying <strong>the</strong>ir<br />

vehicles to <strong>the</strong> East Second Street site. Zipcar has indicated that, while <strong>the</strong>y have<br />

no interest in bringing Zipcar to <strong>the</strong> site before development, <strong>the</strong>y would have an<br />

interest in doing so after <strong>the</strong> new buildings are built. The proponent will also<br />

contact Planet Trans who provides a similar service. Planet Trans is a Cambridge<br />

start-up which now supplies Toyota Prius hybrids to Genzyme employees and is<br />

looking to expand <strong>the</strong>ir fleet of low-emission vehicles. The proponent would like<br />

to encourage <strong>the</strong>m to acquire plug-in Prius hybrids, potentially on a cost-sharing<br />

basis.<br />

Car Pooling<br />

The new buildings, with 79 units, are expected to house approximately 150<br />

residents. The existing Distillery building has approximately <strong>the</strong> same number of<br />

residents. It is believed that a considerable portion of <strong>the</strong> on-site tenants would<br />

9.0 Transportation Access Plan 9-52


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

use a carpool service if one were provided. Fur<strong>the</strong>r, <strong>the</strong>re is or will soon be an<br />

additional 600 residents not more than 2 blocks from <strong>the</strong> project site. Therefore,<br />

including existing residents it is estimated that <strong>the</strong>re are approximately 900<br />

residents within 2 blocks who might be candidates for car pooling at <strong>the</strong> site.<br />

The proponent conducted a survey of existing tenants indicating that most<br />

commute to a few locations: <strong>the</strong> downtown business district, Harvard Square, <strong>the</strong><br />

Museum of Fine Arts area, <strong>the</strong> South End, and Jamaica Plain. This narrow range<br />

of destinations makes carpooling attractive. The proponent feels that <strong>the</strong><br />

difficulty with most existing car pools is that <strong>the</strong>y are rigid in pairing drivers and<br />

riders, and are inflexible in <strong>the</strong>ir scheduling. A passenger must meet <strong>the</strong> same<br />

driver at <strong>the</strong> same time on prearranged days. This rigidity does not fit <strong>the</strong> flexible<br />

schedules of artists and part-time workers who make up many of <strong>the</strong> project’s<br />

existing tenants, and does not fit <strong>the</strong> schedules of <strong>the</strong> artists, young professionals,<br />

or retirees who we expect to be a substantial portion of <strong>the</strong> new residents.<br />

Computerized systems which employ java-based queuing software relax <strong>the</strong>se<br />

constraints. Using a java-capable cellular phone or a web-connected computer<br />

terminal, a system user can schedule to be ei<strong>the</strong>r a driver or passenger in as little<br />

as 15 minutes before departure. The developer has met with Robin Chase, <strong>the</strong><br />

developer of Go Loco, a sophisticated computerized car pool system which is set<br />

to pilot in February 2007 and anticipated to be in operation in March of 2007. We<br />

have proposed that <strong>the</strong> existing tenants at <strong>the</strong> Distillery would be part of <strong>the</strong> beta<br />

trial.<br />

Robin Chase is a founder of Zipcar, and brings over to computerized car pooling<br />

<strong>the</strong> computer sophistication and business planning that made Zipcar a success.<br />

Under this system, riders would be able to access intersecting car pool<br />

populations. The Distillery might be one, Mass General Hospital or City Hall<br />

might be ano<strong>the</strong>r. Potential ridership might be fur<strong>the</strong>r sorted by rider and ride<br />

provider preferences, to conform to social or professional groupings. Fur<strong>the</strong>r,<br />

each driver and rider will have an on-line profile which can be accessed and<br />

9.0 Transportation Access Plan 9-53


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

added to by o<strong>the</strong>rs in <strong>the</strong> system. This would provide feedback on unreputable<br />

participants, much as E-bay does.<br />

The system would share all costs of <strong>the</strong> ride, with <strong>the</strong> rider paying 50% and <strong>the</strong><br />

driver paying 20% of <strong>the</strong> income to Go Loco. This system <strong>the</strong>refore qualifies as a<br />

cost sharing arrangement, ra<strong>the</strong>r than a taxi or limo service. Riders and drivers’<br />

security and safety is increased by <strong>the</strong> closed nature of each of <strong>the</strong>se ride-sharing<br />

groups, by <strong>the</strong> review of members by participants, and by <strong>the</strong> fact that each<br />

participant has a “buddy” who is informed on-line about <strong>the</strong> time, destination and<br />

persons involved in each transport transaction.<br />

Go Loco is a timely and, in our view, very well developed plan for computerized<br />

car pooling, which will integrate with our plans to make it feasible for people to<br />

conveniently avoid car ownership.<br />

Shuttle Service<br />

The grouping of destinations in <strong>Boston</strong> and Cambridge locations indicates that a<br />

shuttle service may be feasible. On <strong>the</strong> one hand, <strong>the</strong> distances are small and <strong>the</strong><br />

degree of congestion since <strong>the</strong> Big Dig is manageable. However, <strong>the</strong> cost of<br />

parking is high and often cannot be obtained exactly at <strong>the</strong> desired destination.<br />

Shuttle vans provide portal to portal service, or drop-offs to major public<br />

transportation links.<br />

The proponent intends to provide one or two shuttle vans available to residents<br />

and those from <strong>the</strong> surrounding blocks. Computer-based reservation<br />

software would coordinate ridership to minimize both near-empty runs and<br />

overflows that strand potential riders.<br />

The proponent is following <strong>the</strong> availability of Mercedes’ plug-in Sprinter vans<br />

which are now being test-marketed in <strong>the</strong> US. The shuttle service could be run by<br />

<strong>the</strong> proponent or by an outside vendor. The proponent has been in contact with<br />

<strong>Boston</strong> Coach and o<strong>the</strong>rs with whom <strong>the</strong>y would like to enter into a cost-sharing<br />

agreement for <strong>the</strong> premium cost of plug-ins.<br />

9.0 Transportation Access Plan 9-54


Improved Bus Service<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Many of <strong>the</strong> prospective tenants or condo owners would commute toward<br />

downtown. Currently, <strong>the</strong> closest public transportation is <strong>the</strong> No. 9 bus on East<br />

Broadway and H Street, three blocks away. The No. 7 bus runs from Otis and<br />

Summer Streets to City Point. During morning rush hours, Route 7 operates<br />

outbound from Downtown along Summer Street and serves <strong>the</strong> Harbor Industrial<br />

Park by turning right onto Pappas Way, and a left onto East First Street to City<br />

Point. Approximately half of <strong>the</strong> outbound morning peak period buses travel this<br />

diverted route to serve <strong>the</strong> Industrial Park. It returns downtown along Summer<br />

Street. During evening rush hours, it leaves City Point, travels down East First<br />

Street past <strong>the</strong> project site, taking a right onto Pappas Way to serve <strong>the</strong> Industrial<br />

Park, and <strong>the</strong>n continues onto Summer Street into downtown, and returns<br />

outbound to City Point along Summer Street. Again, approximately half of <strong>the</strong><br />

inbound buses travel this diverted route to serve <strong>the</strong> Industrial park in <strong>the</strong> evening<br />

peak period. Changes to <strong>the</strong> service in improve <strong>the</strong> service for tenants wanting to<br />

pick-up <strong>the</strong> Route 7 along East First Street is being discussed with <strong>the</strong> MBTA. It<br />

should be noted that Pappas Way is a private road and changes in <strong>the</strong> service<br />

would need to be discussed with <strong>the</strong> roadway owner. Fur<strong>the</strong>r, <strong>the</strong>re may be riders<br />

who currently pick up Route 7 along Summer Street who would have a decrease<br />

in <strong>the</strong>ir service.<br />

A preliminary discussion with <strong>the</strong> MBTA indicated a willingness to continue<br />

looking at <strong>the</strong>se service modifications. The proponent is contacting tenants and<br />

residents in adjacent buildings to determine if sufficient ridership currently exists<br />

for <strong>the</strong>se service improvements.<br />

Plug-In Hybrid Energy and Fuel Cost Savings<br />

The development project is unique in <strong>the</strong> integration of distributed power<br />

generation and plug-in hybrids. The proponent will use diesel generator<br />

equipment which runs on vegetable oil developed by Schmitt Enertec (Mayen,<br />

Germany) and installed and maintained by Kraft Power (Woburn, MA). These<br />

9.0 Transportation Access Plan 9-55


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

will produce power in a way which is minimally polluting and virtually carbon<br />

neutral. At market rates for vegetable oil, generated electrical power (subtracting<br />

<strong>the</strong> value of its useable heat and REC’s credits) will cost around 6 cents per<br />

kilowatt hour (kwh).<br />

Plug-in hybrids are three times as efficient as in-vehicle gasoline engines in miles<br />

per gallon of fuel burned 4 . With a distributed power system representing a<br />

roughly 1:1 ratio of electricity and heat, <strong>the</strong> efficiency of miles per gallon of fuel<br />

is raised to six times <strong>the</strong> efficiency of a conventional gasoline automobile.<br />

At 10 cents/kwh, plug-in hybrids will cost <strong>the</strong> equivalent of 50 cents/gallon to<br />

run. At <strong>the</strong> project’s lower electric rates, that cost is <strong>the</strong>oretically lowered to 30<br />

cents a mile. The use of distributed power and plug-in hybrids represents an<br />

experiment which may potentially set new benchmarks in nonpolluting fuel use<br />

and fuel economy.<br />

Transportation and Building Layout<br />

The project is designed in accordance with its transportation aims. The two new<br />

buildings come toge<strong>the</strong>r at <strong>the</strong> corner of Dorchester Street and East First Street.<br />

There will be a café on level three (even with <strong>the</strong> grade of <strong>the</strong> interior courtyard<br />

and above <strong>the</strong> two levels of parking) where people can assemble to wait for <strong>the</strong><br />

bus, to take <strong>the</strong> shuttles, or to pick up a car pool ride. To depart by bus, people<br />

will go downstairs (16 ft) to a wea<strong>the</strong>r-protected lobby on <strong>the</strong> corner of<br />

Dorchester Street and First Street, and from <strong>the</strong>re to <strong>the</strong> bus stop across <strong>the</strong> street.<br />

Access will be provided to parking level 2, from which <strong>the</strong> commuter vans will<br />

depart. A third option allows <strong>the</strong>m to go to <strong>the</strong> designed numbered parking space<br />

in <strong>the</strong> two-level garage to pick up <strong>the</strong>ir car pool ride. All information about bus<br />

schedules, van and carpool deployments, will be accessible by a large monitor in<br />

4 Scientific American, April 2006 “Hybrid Vehicles Gain Traction,” Technology Review, May 24th, 2006.<br />

Plug-in Hybrids are on <strong>the</strong> Way.<br />

9.0 Transportation Access Plan 9-56


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

<strong>the</strong> café. Computer terminals at several tables will allow ride scheduling on <strong>the</strong><br />

spot.<br />

The café will be an attractive social meeting place, with a patio open to <strong>the</strong><br />

courtyard in good wea<strong>the</strong>r, an adjacent art gallery, and a view out to First Street<br />

and <strong>the</strong> city skyline.<br />

9.6.3 Loading and Service Management Actions<br />

Service and loading activities for <strong>the</strong> development is accommodated in <strong>the</strong> dock<br />

area located within <strong>the</strong> building and from <strong>the</strong> driveway area in <strong>the</strong> central<br />

courtyard. Access to <strong>the</strong> main loading dock is via a driveway located on H Street.<br />

The majority of goods and services delivered to tenants and residents of <strong>the</strong><br />

Distillery project will be primarily by single-panel trucks or smaller delivery<br />

vehicles such as vans. Typical deliveries will include artists’ supplies, residential<br />

moves and trash collection for <strong>the</strong> building. The loading dock has been designed<br />

to accommodate 35-foot vehicles (SU-35) without encroaching onto sidewalks<br />

and driveways. Occasionally longer vehicles may visit <strong>the</strong> site. The dock staff<br />

will actively manage <strong>the</strong>se occasions. It is anticipated that Federal Express, o<strong>the</strong>r<br />

package and mail deliveries will come through <strong>the</strong> main building entrance within<br />

<strong>the</strong> courtyard area accessed via <strong>the</strong> driveway located on East Second Street.<br />

These trucks can execute three-point turnarounds in <strong>the</strong> area near <strong>the</strong> current main<br />

entrance. There will also be a loading area on <strong>the</strong> first level of <strong>the</strong> garage for <strong>the</strong><br />

condominium units accessed via Dorchester Street.<br />

9.6.4 Construction Management<br />

The proponent will develop a detailed evaluation of potential short-term<br />

construction-related transportation impacts including construction vehicle traffic,<br />

parking supply and demand, and pedestrian access. Detailed Construction<br />

Management Plans will be developed and submitted to <strong>the</strong> BTD for <strong>the</strong>ir<br />

approval. These plans will detail construction vehicle routing and staging.<br />

9.0 Transportation Access Plan 9-57


Construction Vehicle Traffic<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Construction vehicles will be necessary to move construction materials to and<br />

from <strong>the</strong> project sites. Every effort will be made to reduce <strong>the</strong> noise, control<br />

fugitive dust, and minimize o<strong>the</strong>r disturbances associated with construction<br />

traffic. It is anticipated that East First Street will serve as <strong>the</strong> principal<br />

construction traffic route. Truck staging and lay-down areas for <strong>the</strong> project will<br />

be carefully planned. The need for street occupancy (lane closures) along<br />

roadways adjacent to <strong>the</strong> project site is not known at this time.<br />

Construction Parking Issues<br />

Contractors will be encouraged to devise access plans for <strong>the</strong>ir personnel that deemphasize<br />

auto use (such as seeking off-site parking, provide transit subsidies,<br />

on-site lockers, etc.) Construction workers will be encouraged to use public<br />

transportation to access <strong>the</strong> project site because no new parking will be provided<br />

for <strong>the</strong>m. Because of <strong>the</strong> construction workers early arrival/departure (7:00AM-<br />

3:00PM) schedule, a conflict for on-street parking is not anticipated.<br />

Pedestrian Access During Construction<br />

During <strong>the</strong> construction period, pedestrian activity adjacent to <strong>the</strong> parcels may be<br />

impacted by sidewalk closures. A variety of measures will be considered and<br />

implemented to protect <strong>the</strong> safety of pedestrians. Temporary walkways,<br />

appropriate lighting, and new directional and informational signage to direct<br />

pedestrians around <strong>the</strong> construction sites will be provided. After construction is<br />

complete, finished pedestrian sidewalks will be permanently reconstructed to<br />

meet ADA standards around <strong>the</strong> new facilities. Any damage as a result of<br />

construction vehicles or o<strong>the</strong>rwise will be repaired per City standards.<br />

9.0 Transportation Access Plan 9-58


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

9.7 TRANSPORTATION ACCESS PLAN AGREEMENT & CONSTRUCTION<br />

MANAGEMENT PLAN<br />

As required by <strong>the</strong> Article 80 process, <strong>the</strong> Proponent will prepare and submit a<br />

Transportation Access Plan Agreement (TAPA) and Construction Management<br />

Plan (CMP) for review by <strong>the</strong> BTD and o<strong>the</strong>r City of <strong>Boston</strong> agencies as<br />

appropriate.<br />

Specifically, <strong>the</strong> TAPA will address <strong>the</strong> following:<br />

• Assessment of overall traffic impacts and mitigation adequacy;<br />

• Assessment of construction traffic impacts and mitigation;<br />

• Monitoring and mitigation of traffic impacts; and<br />

• Management of loading and deliveries.<br />

The following are some of <strong>the</strong> elements that are anticipated to be included in a<br />

forthcoming CMP to support <strong>the</strong> project:<br />

• The primary vehicular access to <strong>the</strong> project site during <strong>the</strong> construction period<br />

will be from East First Street.<br />

• The construction site will be maintained on private property and will likely<br />

not require long-term roadway and/or sidewalk occupancies (o<strong>the</strong>r than for<br />

utilities connections, <strong>the</strong> reconstruction of new driveways and sidewalks,<br />

lighting, and street furniture.<br />

• Construction worker parking will be provided on-site.<br />

• A majority of staging areas for construction are anticipated to be located<br />

directly on <strong>the</strong> site.<br />

9.0 Transportation Access Plan 9-59


APPENDIX 9-1 SOUTH BOSTON PARKIN G FREEZE<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

9.0 Transportation Access Plan 9-60


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

9.0 Transportation Access Plan 9-61


10.0 INFRASTRUCTURE SYSTEMS<br />

10.1 INTRODUCTION<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The Distillery project will connect to existing city and utility company systems in<br />

<strong>the</strong> adjacent public streets. This chapter evaluates <strong>the</strong> infrastructure systems that<br />

will support <strong>the</strong> project. Based on initial investigations and consultations with <strong>the</strong><br />

appropriate agencies and utility companies, existing infrastructure systems are<br />

available at <strong>the</strong> project site and appear adequately sized to accept <strong>the</strong> incremental<br />

increase in demand associated with <strong>the</strong> development and operation of <strong>the</strong> project.<br />

The following utilities were reviewed: wastewater, water, drainage, electricity and<br />

telecommunications. In addition, consideration was given to <strong>the</strong> sustainable<br />

elements of <strong>the</strong> energy supply provision for <strong>the</strong> project.<br />

This project will include a number of innovative sustainable design features<br />

aimed at reducing <strong>the</strong> depletion of natural resources through increased<br />

efficiencies, selection in materials and overall design philosophy. This will<br />

ultimately result in a lower operating demand for building systems. The project is<br />

still in <strong>the</strong> design process and <strong>the</strong>se exact savings will be refined and documented<br />

as <strong>the</strong> project moves forward. For <strong>the</strong> purposes of this section we have carried<br />

typical generation rates for sewer and water as well as initial design demands and<br />

service needs for energy systems to ensure that this evaluation takes a<br />

conservative approach to <strong>the</strong> availability of public and private utility systems.<br />

The final design process for <strong>the</strong> project will include all required engineering<br />

analyses and will adhere to all applicable protocols and design standards, ensuring<br />

that <strong>the</strong> proposed buildings are properly supported by, and in turn properly use by<br />

<strong>the</strong> City’s infrastructure. Detailed design of <strong>the</strong> project’s utility systems will<br />

proceed in conjunction with <strong>the</strong> design of <strong>the</strong> buildings and interior mechanical<br />

systems.<br />

10.0 Infrastructure 10-1


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The systems discussed below include those owned or managed by <strong>the</strong> <strong>Boston</strong><br />

Water and Sewer Commission (BWSC), private utility companies and on-site<br />

infrastructure systems. There will be close coordination among <strong>the</strong>se entities and<br />

with <strong>the</strong> Project Engineers and Architects during subsequent reviews and design<br />

process. Figure 10-1 depicts <strong>the</strong> existing utilities infrastructure and Figure 10-2<br />

shows <strong>the</strong> approximate proposed utility locations.<br />

All improvements and connections to BWSC infrastructure will be reviewed by<br />

BWSC as part of <strong>the</strong> BWSC Site Plan Review Process. This process includes a<br />

comprehensive design review of <strong>the</strong> proposed service connections, assessment of<br />

system demands and capacity and establishment of service accounts.<br />

Regulatory Framework<br />

This chapter, in addition to a description of existing and future infrastructure<br />

connections, discusses <strong>the</strong> regulatory framework of utility connection reviews and<br />

standards. All connections will be designed and constructed in accordance with<br />

city, state and federal standards.<br />

• In <strong>the</strong> City of <strong>Boston</strong>, BWSC is responsible for <strong>the</strong> majority of water, sewer<br />

and stormwater systems.<br />

• A sewer connection/extension permit from <strong>the</strong> Massachusetts Department of<br />

Environmental Protection (DEP) will be required.<br />

• The <strong>Boston</strong> Fire Department (BFD) will review <strong>the</strong> Project with respect to fire<br />

protection measures such as siamese connections and standpipes.<br />

• Design of <strong>the</strong> site access, hydrant locations and energy systems (electric) will<br />

also be coordinated with <strong>the</strong> respective system owner.<br />

• New utility connections will be authorized by <strong>the</strong> <strong>Boston</strong> Public Works<br />

Department through <strong>the</strong> street opening permit process, as required.<br />

Additional information on <strong>the</strong> regulatory framework for each utility system is<br />

included in subsequent sections of this chapter.<br />

10.0 Infrastructure 10-2


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

A more complete list of <strong>the</strong> state and local permits anticipated in connection with<br />

<strong>the</strong> project infrastructure is included above in Chapter 3. Figure 10-1 shows <strong>the</strong><br />

existing infrastructure at <strong>the</strong> site.<br />

10.2 WASTEWATER<br />

10.2.1 Existing Wastewater<br />

Local sanitary sewer service in <strong>the</strong> City is provided by <strong>the</strong> BWSC. Sewage<br />

generated by <strong>the</strong> existing building on <strong>the</strong> site is collected by <strong>the</strong> BWSC’s 12-inch<br />

combined sewer and drain line in Dorchester Street. In addition, <strong>the</strong> site is served<br />

by a 36x48-inch and a 20x27-inch combined sewer along East Second Street.<br />

Fur<strong>the</strong>rmore, a 12-inch sewer along East First Street flows into <strong>the</strong> previously<br />

mentioned 36x48-inch combined main in H Street before turning <strong>the</strong> corner<br />

towards East Second Street.<br />

10.2.2 Demand / Use<br />

The Distillery Project’s residential units, including <strong>the</strong> artist live-work studios,<br />

will generate approximately 10,230 gallons per day (gpd). The retail and café<br />

aspects of <strong>the</strong> project are expected to generate an additional 1,919 gpd. The<br />

gallery, greenhouse and remaining commercial area will also contribute 2,837<br />

gpd. A total sewer generation of approximately 15,000 gpd for <strong>the</strong> building<br />

program is expected. Generation rates from <strong>the</strong> Massachusetts State<br />

Environmental Code (Title 5) were used. The project is also expected to generate<br />

additional demand from cooling system operations which will slightly increase<br />

<strong>the</strong> total sewer generation. The project is currently exploring opportunities for<br />

water re-use that would limit this demand.<br />

10.2.3 Proposed Connection<br />

The sanitary collection system in <strong>the</strong> immediately adjacent streets is a combined<br />

system meaning that both drainage and sewerage are conveyed in <strong>the</strong> same lane<br />

10.0 Infrastructure 10-3


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

and are ultimately discharged to <strong>the</strong> wastewater treatment plant at Deer Island.<br />

The city has an ongoing program to eliminate such systems where feasible to limit<br />

unnecessary flows to Deer Island and increase system capacities and limit<br />

potential for overflow of sewerage during rain events. Ideally <strong>the</strong> project will be<br />

designed to support any future separation improvements that are planned. At a<br />

minimum <strong>the</strong> design will include separate drain and sewer connections with <strong>the</strong><br />

ability to be directed to different systems in <strong>the</strong> future. The project team has had<br />

initial discussions with <strong>Boston</strong> Water and Sewer regarding <strong>the</strong> proximity of <strong>the</strong><br />

site planned separation improvements. The proponent will work with BWSC<br />

regarding appropriate location and configurations that correspond with <strong>the</strong><br />

Commission’s larger plan for any separation program.<br />

Sewer service for <strong>the</strong> new building will consist of three residential connections<br />

onto Dorchester Street; and two separate connections along East First Street to<br />

service <strong>the</strong> café and retail portion of <strong>the</strong> project.<br />

The proponent will coordinate with BWSC and <strong>the</strong> necessary agencies on <strong>the</strong><br />

design and capacity for proposed connections to <strong>the</strong> sewer system. In addition,<br />

<strong>the</strong> proponent will submit a General Service Application and site plan, for review,<br />

as <strong>the</strong> project progresses.<br />

The project will generate new wastewater flows exceeding 15,000 gallons per day<br />

which will require a Sewer Connection Permit from <strong>the</strong> DEP.<br />

10.3 DOMESTIC WATER AND FIRE PROTECTION<br />

10.3.1 Existing Water Supply System<br />

Water will be provided by <strong>the</strong> BWSC. There are five different water<br />

systems/service districts within <strong>the</strong> City, which provide service to portions of <strong>the</strong><br />

City based on ground surface elevation. The five systems are sou<strong>the</strong>rn low<br />

(commonly known as low service), sou<strong>the</strong>rn high (commonly known as high<br />

10.0 Infrastructure 10-4


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

service), sou<strong>the</strong>rn extra high, nor<strong>the</strong>rn low and nor<strong>the</strong>rn high. Water service for<br />

<strong>the</strong> existing building is supplied by a 12-inch sou<strong>the</strong>rn low service in Dorchester<br />

Street. The project site is also serviced by a 12-inch sou<strong>the</strong>rn high line in East<br />

First, East Second and H Streets along with a 12-inch sou<strong>the</strong>rn low service main<br />

in East First Street.<br />

Domestic water demand is based on estimated sewage generation with an added<br />

factor of 10 percent for consumption, system losses and o<strong>the</strong>r use. Based upon<br />

sewage generation rates outlined in <strong>the</strong> DEP Sewer Connection and Extension<br />

Regulations, 310 CMR 15.203.f, <strong>the</strong> Project will require approximately 16,500<br />

gallons of water per day. Additional demand will be required as “make-up” water<br />

for operation of <strong>the</strong> building cooling systems resulting in an increase of <strong>the</strong> total<br />

demand. However, water re-use will be pursued for limited building uses. Total<br />

demand will be defined as <strong>the</strong> project design is developed.<br />

Hydrant test data was obtained from BWSC for hydrants located on H Street and<br />

East First Street. The test results, provided in Table 10-1, indicate <strong>the</strong>re is<br />

adequate flow and pressure in <strong>the</strong> area to service <strong>the</strong> project.<br />

Table 10-1 Hydrant Flow Results<br />

Date Location Static<br />

Pressure<br />

(psi)<br />

3/25/99 H Street<br />

(hydrant 236)<br />

1/31/97 H Street<br />

(hydrant 236)<br />

1. psi= pounds per square inch<br />

Residual<br />

Pressure<br />

(psi)<br />

Total<br />

Flow<br />

(gpm)<br />

90 65 2126 3707<br />

88 75 1417 3464<br />

Flow<br />

(gpm) @ 20<br />

psi1 The results of <strong>the</strong> hydrant flow test indicate <strong>the</strong> actual amount of water (flow)<br />

available and <strong>the</strong> actual pressure (residual) flow provided. For reference, <strong>the</strong>se<br />

10.0 Infrastructure 10-5


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

numbers are analyzed to establish <strong>the</strong> quantity of water that will be delivered to<br />

<strong>the</strong> project site at 20 psi.<br />

10.3.2 Proposed Connection<br />

The project will be serviced by BWSC’s low service system located in Dorchester<br />

and East First Street for both domestic and fire protection service. Domestic<br />

water service connections required by <strong>the</strong> project will meet <strong>the</strong> applicable city and<br />

state codes and standards, including cross-connection backflow prevention.<br />

Compliance with <strong>the</strong> standards for <strong>the</strong> domestic water system service connections<br />

will be reviewed as part of BWSC’s Site Plan Review Process. The review<br />

includes, but not limited to, sizing of domestic water and fire protection services,<br />

calculation of meter sizing, backflow prevention design, and location of hydrants<br />

and siamese connections conform to BWSC and BFD requirements.<br />

10.4 STORMWATER MANAGEMENT<br />

The project site is currently a combination of areas both pervious and impervious<br />

to rainfall percolation. Construction of <strong>the</strong> project will not produce significant<br />

changes in ei<strong>the</strong>r <strong>the</strong> pattern of, or increase <strong>the</strong> rate of, stormwater runoff. The<br />

project will look to include state of <strong>the</strong> art sustainability measures that will aim to<br />

reduce runoff volumes and reuse resources where possible. Stormwater<br />

management controls will be established in compliance with BWSC standards,<br />

and <strong>the</strong> project will not result in <strong>the</strong> introduction of any peak flows, pollutants, or<br />

sediments that would potentially impact <strong>the</strong> local BWSC stormwater drainage<br />

system.<br />

10.4.1 Existing Conditions<br />

The property is serviced by multiple combined sewer and drain lines along<br />

Dorchester Street, East Second and H Street as mentioned previously. In<br />

10.0 Infrastructure 10-6


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

addition, a 12-inch drain line in East First Street services <strong>the</strong> site where it<br />

eventually discharges to <strong>the</strong> <strong>Boston</strong> Harbor.<br />

The site currently is broken into two sub-watersheds: <strong>the</strong> building area and <strong>the</strong><br />

remaining paved areas. Both <strong>the</strong> existing building and pavement run-off drains to<br />

<strong>the</strong> adjacent drainage system via perimeter catch basins.<br />

10.4.2 Proposed Conditions<br />

Construction of <strong>the</strong> project will not produce significant changes in <strong>the</strong> rate of<br />

stormwater runoff from <strong>the</strong> site. The project courtyard will connect and drain to<br />

<strong>the</strong> main in East Second Street in addition to spaced roof drains along Dorchester<br />

Street.<br />

Remaining stormwater generated from <strong>the</strong> project will be collected on site and<br />

conveyed within a private drainage system for re-use applications to <strong>the</strong> greatest<br />

extent possible. Building run-off will also be controlled by <strong>the</strong> proposed 24-inch<br />

raised bed green roof. As part of BWSC’s review process, <strong>the</strong> proponent will<br />

consider measures wherever applicable to minimize flows leaving <strong>the</strong> site.<br />

Table 10-2 contains stormwater peak runoff estimates for <strong>the</strong> 2-, 10-, 25-, and<br />

100-year storm events. The existing condition runoff is slightly higher than <strong>the</strong><br />

proposed condition runoff.<br />

Table 10-2 Stormwater Runoff<br />

2-year<br />

storm<br />

10-year<br />

storm<br />

25-year<br />

storm<br />

100-year<br />

storm<br />

Estimated existing runoff (cfs) 1 5.44 7.87 9.43 11.34<br />

Estimated future runoff (cfs) 4.31 6.68 8.23 10.13<br />

1. cfs = cubic feet per second<br />

10.0 Infrastructure 10-7


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Stormwater management controls will be established in compliance with BWSC<br />

standards; <strong>the</strong> project will not introduce any increased peak flows, pollutants or<br />

sediments that would potentially impact <strong>the</strong> <strong>Boston</strong> Harbor. In conjunction with<br />

<strong>the</strong> site plan and <strong>the</strong> General Service Application, <strong>the</strong> proponent will submit a<br />

stormwater management plan to BWSC. Compliance with <strong>the</strong> standards for <strong>the</strong><br />

final site design will be reviewed as part of BWSC’s Site Plan Review Process.<br />

10.4.3 Compliance with DEP Stormwater Management Policy<br />

The project involves <strong>the</strong> <strong>redevelopment</strong> of a previously developed site. Standard 7<br />

of <strong>the</strong> Stormwater Management Standards states: “<strong>Redevelopment</strong> of previously<br />

developed sites must meet <strong>the</strong> Stormwater Management Policy to <strong>the</strong> maximum<br />

extent practicable. However, if it is not practicable to meet all <strong>the</strong> Standards, new<br />

(retrofitted or expanded) stormwater management systems must be designed to<br />

improve existing conditions.” To demonstrate <strong>the</strong> ways in which <strong>the</strong> project will<br />

be consistent with <strong>the</strong> Stormwater Management Policy, a discussion of each<br />

Stormwater Management Standard follows:<br />

Standard #1: Untreated Stormwater<br />

The project will treat <strong>the</strong> runoff contributed by plazas and driveway areas through<br />

appropriate stormwater measures. DEP Management Standards identify rooftop<br />

runoff (except certain metal roofs) as uncontaminated for <strong>the</strong> purposes of <strong>the</strong><br />

Stormwater Management Standards.<br />

Standard #2: Post-Development Peak Discharge Rates<br />

The project will employ features such as green roofs and water collection systems<br />

for rainwater re-use that are anticipated to reduce runoff from <strong>the</strong> site. The<br />

proposed condition will also feature more landscaping and pervious surfaces than<br />

currently exist which will fur<strong>the</strong>r reduce runoff from <strong>the</strong> site. Accordingly, <strong>the</strong><br />

post-development discharge rate is expected not to exceed <strong>the</strong> pre-development<br />

10.0 Infrastructure 10-8


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

discharge rate to <strong>the</strong> receiving body of water (<strong>Boston</strong> Harbor). Since <strong>the</strong><br />

discharge rate is not expected to increase, no increased flooding impacts are<br />

expected.<br />

Standard #3: Recharge to Groundwater<br />

The project site is not located with <strong>the</strong> Groundwater Overlay District <strong>the</strong>refore<br />

<strong>the</strong>re is no local requirement for groundwater recharge. However, opportunities<br />

for on-site recharge will be explored as part of <strong>the</strong> stormwater management<br />

design. This will likely be done through pervious pavements (porous asphalt or<br />

open joint pavers) and <strong>the</strong> addition of landscape areas.<br />

Standard #4: 80 Percent Total Suspended Solids Removal<br />

No new surface control structures are proposed. The sidewalk and pavement<br />

runoff will discharge to existing catch basins or proposed inlets constructed in<br />

connection with <strong>the</strong> project.<br />

Standard #5: Higher Potential Pollutant Loads<br />

The project site does not contain land uses with higher potential pollutant loads.<br />

Standard #6: Protection of Critical Areas<br />

The project site does not contain any critical areas.<br />

Standard #7: <strong>Redevelopment</strong> Projects<br />

The project does not increase impervious area and it will meet <strong>the</strong> Stormwater<br />

Management Standards to <strong>the</strong> maximum extent practicable, which is required to<br />

meet Standard #7.<br />

Standard #8: Erosion/Sediment Controls<br />

10.0 Infrastructure 10-9


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The project’s construction documents will include measures and specifications<br />

regarding erosion and sediment controls and barriers (e.g., silt fence, hay bales,<br />

and catch basin sacks). Construction dewatering discharges will be appropriately<br />

controlled and discharged in accordance with National Pollutant Discharge<br />

Elimination System (NPDES) and state dewatering standards.<br />

Standard #9: Operation/Maintenance Plan<br />

An Operation and Maintenance plan will be developed for both construction and<br />

post-development, which will include, at a minimum, system ownership<br />

information, parties responsible for operation and maintenance, and inspection<br />

and maintenance schedules. Routine maintenance is expected to include catch<br />

basin cleaning, stormwater control cleaning and removal of debris from outlets. It<br />

is also expected that pedestrian and vehicular access ways will be swept<br />

appropriately to control sand applied during winter months.<br />

Measures aimed at minimizing <strong>the</strong> disposition of site soils to off-site areas,<br />

primarily <strong>the</strong> surrounding streets and existing drainage collection systems, will be<br />

a part of <strong>the</strong> City’s required Construction Management Plan. In addition, <strong>the</strong><br />

proponent will apply for all appropriate permits for construction activity and<br />

dewatering. All efforts will be made to contain sediment, pollutants and any o<strong>the</strong>r<br />

construction-related materials within <strong>the</strong> site. Stabilized construction<br />

entrances/exits will be installed at each access point of <strong>the</strong> work areas to minimize<br />

off-site transport of soil by construction vehicles. These entrances/exits will<br />

remain in place until site areas have been stabilized. In addition, <strong>the</strong> proponent<br />

will use Best Management Practices (BMPs) during construction including<br />

installing silt sacks on catch basins, a truck-trailer wheel wash station, antitracking<br />

pads and covering material piles.<br />

10.0 Infrastructure 10-10


10.5 ANTICIPATED ENERGY NEEDS<br />

10.5.1 Electrical Service<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

One of <strong>the</strong> primary features of <strong>the</strong> project’s sustainable design is <strong>the</strong> inclusion of a<br />

vegetable oil based cogeneration system that will be designed to provide<br />

electricity and heating service demand for <strong>the</strong> site. This system will be connected<br />

to <strong>the</strong> NSTAR system which will provide any unusual peak needs and service<br />

when <strong>the</strong> cogeneration system is under maintenance.<br />

NSTAR has service in East First, East Second and H Street. Availability of<br />

service will be determined as <strong>the</strong> building design progresses; however less<br />

demand will be required from NSTAR compared with o<strong>the</strong>r developments. A<br />

proposed connection to East First Street will provide service for <strong>the</strong> reserve<br />

electrical system. The proponent will work with NSTAR on particulars as <strong>the</strong><br />

project design advances.<br />

10.5.2 Natural Gas<br />

It is not <strong>the</strong> intention of this project to use gas as an energy source since it is not<br />

cost effective and is associated with health problems in residential settings.<br />

10.5.3 Telecommunications<br />

It is <strong>the</strong> proponent’s goal as a sustainability initiative to accommodate <strong>the</strong> latest<br />

available telecommunications system configuration for enhanced speed and<br />

mobility enabling site residents to telecommute.<br />

The proponent will select private telecommunications companies to provide<br />

telephone, cable and data services. There are several potential candidates with<br />

substantial downtown <strong>Boston</strong> networks capable of providing service. Upon<br />

selection of a provider or providers, <strong>the</strong> proponent will coordinate service<br />

connection locations and obtain appropriate approvals.<br />

10.0 Infrastructure 10-11


10.6 PROTECTION OF UTILITIES<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Existing public and private infrastructure located within <strong>the</strong> public right-of-way<br />

will be protected during construction. The installation of proposed utilities within<br />

<strong>the</strong> public way will be in accordance with BWSC, <strong>Boston</strong> Public Works<br />

Department, <strong>the</strong> Dig-Safe Program and governing utility company requirements.<br />

All necessary permits will be obtained before <strong>the</strong> commencement of work.<br />

Specific methods for constructing proposed utilities where <strong>the</strong>y are near to, or<br />

connect with, existing water, sewer or drain facilities will be reviewed by BWSC<br />

as part of its Site Plan Review Process.<br />

10.7 SUSTAINABLE DESIGN / ENERGY CONSERVATION<br />

The proposed buildings will use an engineering approach to achieve reduction in<br />

energy use and environmental impact which until now has been achievable only<br />

by small-scale experimental architecture. This approach involves three main<br />

factors: building geometry, cogeneration of electricity with renewable fuel, and<br />

energy efficient shell and floor slabs. O<strong>the</strong>r techniques, passive solar heat gain,<br />

heliostats, daylighting, natural venting and heat recovery venting are included in<br />

our design, but play a lesser role in <strong>the</strong> energy performance. Integration of<br />

electrical cogeneration, plug-in hybrid vehicles and o<strong>the</strong>r innovative<br />

transportation initiatives also contribute to benchmark setting reductions in <strong>the</strong><br />

total energy and environmental impact of <strong>the</strong> site.<br />

The geometry of most buildings in South <strong>Boston</strong> (and many o<strong>the</strong>r neighborhoods)<br />

is energy inefficient with one to three unit free-standing dwellings with narrow<br />

alleys between <strong>the</strong>m. The proposed building on Dorchester Street takes <strong>the</strong><br />

compact form of attached row houses extended to a depth of 76 feet (as opposed<br />

to a more typical 40 to 50 feet). By including a central atrium light and air is<br />

brought to <strong>the</strong> inner portion of <strong>the</strong> building. Carefully designed fenestration and<br />

<strong>the</strong> use of heliostats minimize energy loss from <strong>the</strong> atrium while maximizing<br />

daylight.<br />

10.0 Infrastructure 10-12


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

For <strong>the</strong> First Street building <strong>the</strong> site dictates a building depth of 56 feet, so an<br />

atrium is not necessary, instead getting light and air into <strong>the</strong> habitable spaces from<br />

windows on both sides. Both buildings are designed without a central corridor in<br />

order to allow through-ventilation and <strong>the</strong>refore <strong>the</strong> possibility of nighttime<br />

cooling and associated energy savings. Concrete floor slabs and o<strong>the</strong>r use of<br />

<strong>the</strong>rmal mass will also reduce peak energy loads. With a tight and highly<br />

insulated building enclosure, energy use is expected to be 40% of that of a new<br />

building to code of similar geometry, and around 25% when compared to<br />

structures with a more typical geometry.<br />

The electrical loads will be supplied by on site internal combustion generators<br />

fueled by vegetable oil (or biodiesel). Energy models show that <strong>the</strong> building will<br />

be in balance, so that <strong>the</strong> heat from electrical generation is sufficient for <strong>the</strong> heat,<br />

hot water, and cooling needs of <strong>the</strong> building. Cooling will be achieved with <strong>the</strong><br />

application of adsorption chillers. The balanced use of heat from cogeneration of<br />

electricity for all <strong>the</strong> <strong>the</strong>rmal loads pushes <strong>the</strong> energy efficiency of <strong>the</strong> building up<br />

to 80% reduction from buildings of similar geometry, and 90% improvement over<br />

typical geometry.<br />

In <strong>the</strong> energy planning of <strong>the</strong> building, <strong>the</strong> objective has been to avoid all<br />

technologies that are not cost-effective relative to greenhouse-gas producing<br />

alternatives. For that reason solar photovoltaics have not been included since at<br />

current prices <strong>the</strong>y produce electricity at an unsubsidized $.27/kWh.<br />

Cogeneration of electricity with vegetable oil produces electricity well below<br />

current market rates after accounting for <strong>the</strong> value of <strong>the</strong> recoverable heat. As <strong>the</strong><br />

electricity is generated from a renewable biofuel, <strong>the</strong>re is <strong>the</strong> option of selling<br />

RECS and reducing <strong>the</strong> cost of electricity at this site to near zero. The economics<br />

of this technology is expected to make this building a model attractive for o<strong>the</strong>rs<br />

to adopt.<br />

10.0 Infrastructure 10-13


10.8 CONCLUSION<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The Distillery Project will use <strong>the</strong> existing water, sewer, and electrical systems<br />

available in public streets adjacent <strong>the</strong> project site. Research and coordination to<br />

date indicates that <strong>the</strong>se services have <strong>the</strong> ability to support <strong>the</strong> increased demands<br />

associated with <strong>the</strong> development of <strong>the</strong> project. The proponent will continue to<br />

work with <strong>the</strong> utility authorities on <strong>the</strong> design and servicing of <strong>the</strong> proposed<br />

project. The project is consistent with DEP’s Stormwater Management Policy<br />

and it incorporates a number of sustainable design and energy conservation<br />

measures.<br />

10.0 Infrastructure 10-14


11.0 GEOTECHNICAL IMPACT 1<br />

11.1 Project Description<br />

General<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The 516 East Second Street project in South <strong>Boston</strong>, Massachusetts consists<br />

of <strong>the</strong> design and construction of a proposed four-story residential complex<br />

with an attached greenhouse and an underground parking garage. The new<br />

residential complex will replace two existing structures at <strong>the</strong> site along<br />

Dorchester Street and East 1st Street. This report provides geotechnical<br />

design recommendations for <strong>the</strong> proposed residential construction.<br />

The geotechnical scope of work performed by Weidlinger Associates, Inc.<br />

(Weidlinger) for this project comprises:<br />

1. Collection and review of available data on subsurface conditions in<br />

<strong>the</strong> project area.<br />

2. Observation and documentation of subsurface explorations<br />

consisting of geotechnical borings.<br />

3. Summary of available boring data; a generalized interpretation of<br />

subsurface conditions; recommended design values for soil<br />

engineering properties based on laboratory and field test data.<br />

4. Geotechnical engineering analyses and design and construction<br />

recommendations.<br />

5. Summary of data and recommendations in a Geotechnical Report.<br />

The analysis excludes all environmental related work <strong>the</strong>refore<br />

environmental-related issues are not addressed in this report.<br />

Existing Conditions<br />

1 The source of this chapter (with a very few syntactical edits) is a report on <strong>the</strong> site at 516 East Second Street, South<br />

<strong>Boston</strong> by Weidlinger Associates Inc. Final Geotechnical Data and Geotechnical Engineering Report dated January<br />

13 th 2006.<br />

11.0 Geotechnical Impact 11-1


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Three structures are currently present at <strong>the</strong> site: (1) a seven-story brick<br />

building with a basement level located at <strong>the</strong> sou<strong>the</strong>ast corner of <strong>the</strong> site, (2) a<br />

one-story brick warehouse with a mezzanine situated along Dorchester Street<br />

on <strong>the</strong> western side of <strong>the</strong> property, and (3) a one-story cinderblock building<br />

on <strong>the</strong> northwest section of <strong>the</strong> site. Nei<strong>the</strong>r of <strong>the</strong> one-story structures has a<br />

basement level. The locations of <strong>the</strong> existing buildings are shown in Figure<br />

11-2, Project Site Aerial Photograph. The proposed residential complex will<br />

be located along East First Street and Dorchester Street as shown in The<br />

Architectural Drawings; and <strong>the</strong> one-story brick warehouse and cinderblock<br />

building will be razed to make room for <strong>the</strong> new condominium complex.<br />

11.2 Subsurface Exploration Program<br />

The subsurface exploration program conducted at 516 East Second Street<br />

consisted of seven (7) test borings (WB-1 through WB-7) drilled from<br />

November 8 to November 18, 2005 by New England Boring Contractors, Inc.<br />

of Glastonbury, Connecticut. The seven borings included standard split spoon<br />

sampling at five-foot intervals in accordance with <strong>the</strong> procedures of ASTM<br />

D1586. In addition, groundwater elevations were measured in each of <strong>the</strong><br />

boreholes during <strong>the</strong> drilling operation. A Weidlinger representative was<br />

present during <strong>the</strong> explorations to observe and document <strong>the</strong> operations and<br />

<strong>the</strong> conditions encountered.<br />

The purpose of <strong>the</strong> test borings was to determine <strong>the</strong> type and properties of <strong>the</strong><br />

subsurface soils in <strong>the</strong> vicinity of <strong>the</strong> proposed condominiums. The locations<br />

of <strong>the</strong> test borings are shown on Figure 11-3, Boring Location Plan. The<br />

borings were advanced using rotary drilling methods and four-inch casing,<br />

with <strong>the</strong> exception of WB-2, located within <strong>the</strong> existing warehouse, which<br />

was advanced with three-inch casing. Test boring logs are provided in Table<br />

11-3 at <strong>the</strong> end of this chapter. Descriptions of subsurface conditions observed<br />

from <strong>the</strong>se borings are presented in Section 11.3 below.<br />

11.0 Geotechnical Impact 11-2


11.3 Subsurface Conditions<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The seven borings drilled during <strong>the</strong> subsurface exploration program<br />

terminated at depths ranging from 37 feet below ground surface (bgs) for WB-<br />

2 to 72 feet bgs for WB-5. Summary of boring depth and surface elevation at<br />

<strong>the</strong> borings are included as Table 11-1.<br />

Table 11-1 Summary of Boring Depths and Depth to Water Table<br />

Measurement Measurement Ground Water Boring Boring<br />

Location Date Elevation (ft) Elevation (ft) Depth (ft)<br />

WB-1 11/11/05 8:00am 17.5 31.5 60.0<br />

WB-2 11/17/05 1:00 pm 11.5 19.5 37.0<br />

WB-3 11/9/05 10:50am 12.0 18.0 45'9"<br />

WB-4 11/11/05 11:30am 9.5 18.5 52.0<br />

WB-5 11/14/05 1:50pm 9.5 21.5 72.0<br />

WB-6 11/14/05 12.5 27.5 52.0<br />

WB-7 11/16/05 16.0 29.0 58.0<br />

Groundwater level measurements were made while boreholes were open during <strong>the</strong> boring program.<br />

Based on conditions encountered in <strong>the</strong>se borings, surficial deposits consist<br />

primarily of four strata: Miscellaneous Fill, Sand, Clay and Till. Of <strong>the</strong> seven<br />

borings, rock was encountered only in boring WB-7 at approximately 56 feet<br />

bgs. The rock is identified as gray wea<strong>the</strong>red Argillite. The rock sample was<br />

retrieved in <strong>the</strong> SPT sampler and not from rock core, <strong>the</strong>refore, though <strong>the</strong><br />

presence of <strong>the</strong> rock likely mark <strong>the</strong> top of rock at that location, this finding is<br />

not conclusive.<br />

Subsurface profiles derived based on conditions encountered at <strong>the</strong> borings are<br />

shown in Figure 11-4. Following is a brief description of <strong>the</strong> surficial deposits<br />

11.0 Geotechnical Impact 11-3


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

at <strong>the</strong> boring locations and <strong>the</strong> general site geology at <strong>the</strong> condominium<br />

complex:<br />

Miscellaneous Fill<br />

The soil borings indicate that portions of <strong>the</strong> site area are covered with<br />

approximately 4 to 17 feet of miscellaneous fill. Fill was encountered in all<br />

borings except for WB-2 and WB-7. In general, <strong>the</strong> fill sampled consisted of<br />

brown fine to coarse sand and varying amounts of ash/cinders, gravel, and<br />

fines. Occasional fragments of brick and concrete were encountered within <strong>the</strong><br />

fill. The fill ranged in density from very loose to very dense, with <strong>the</strong> Standard<br />

Penetration Test (SPT) N-values ranging from 2 blows per foot to a blow<br />

count of 50/2”.<br />

Sand<br />

A sand layer was found underlying <strong>the</strong> miscellaneous fill in borings WB-1,<br />

throughout <strong>the</strong> entire boring in WB-2, between two clay layers in boring WB-<br />

3, and at ground level and directly beneath a sand and gravel stratum in WB-7.<br />

This sand layer was not encountered in WB-4, WB-5, and WB-6. The<br />

thickness of this stratum ranged from 2 feet in boring WB-3 to over 37 feet in<br />

boring WB-2.<br />

The density of <strong>the</strong> sand is medium dense to very dense, with SPT N-values<br />

ranging from 23 blows per foot to a blow count of 100/6”. This stratum can be<br />

described as brown fine to coarse sand with varying amount of silt and gravel.<br />

Based on its relative density and neighboring deposits, it is probable that this<br />

sand layer was deposited as glacial outwash.<br />

Clay<br />

At borings WB-3, WB-4, and WB-5, a 5 to 33-foot thick layer of clay was<br />

encountered beneath <strong>the</strong> miscellaneous fill. At borings WB-3 and WB-7, a<br />

clay stratum was also found below a sand layer. Clay was not encountered in<br />

11.0 Geotechnical Impact 11-4


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

borings WB-1, WB-2, or WB-6. The consistency of <strong>the</strong> clay is medium stiff to<br />

very hard, with SPT N-values ranging from 6 to 40 blows per foot. This clay<br />

stratum can be described as gray clay with varying amounts of sand and silt<br />

with occasional traces of gravel. Based on <strong>the</strong> local geology and <strong>the</strong> visual<br />

classification of <strong>the</strong> samples obtained, this clay stratum was probably<br />

deposited under a marine environment and is locally known as <strong>Boston</strong> Blue<br />

Clay.<br />

Till<br />

A layer of till consisting of sand and gravel was found directly below <strong>the</strong><br />

miscellaneous fill at boring WB-6, beneath a sand layer in WB-7, and at <strong>the</strong><br />

base of borings WB-1, WB-3, WB-4, and WB-5. The thickness of this layer<br />

ranged from 7 feet in WB-7 to over 42 feet in WB-1. Since borings WB-1,<br />

WB-3, WB-4, WB-5, and WB-6 terminated in this till stratum, <strong>the</strong> thickness<br />

of this layer cannot be assessed based on existing borings. The density of this<br />

stratum is dense to very dense, with SPT N-values ranging from 32 blows per<br />

foot to a blow count of 100/3”. The sand and gravel layer can be described as<br />

brown fine to coarse sand and gravel with varying amounts of silt.<br />

Site Geology<br />

Figure 11-5 shows <strong>the</strong> bedrock geology map of <strong>the</strong> <strong>Boston</strong> area. As indicated on<br />

Figure 11-5, in <strong>the</strong> vicinity of <strong>the</strong> project site, <strong>the</strong> underlying rock is expected to<br />

be soft rocks such as Argillite, slate, volcanic ash, and sandstone. A small amount<br />

of Argillite was encountered at <strong>the</strong> bottom of Boring WB-7 thus indicating <strong>the</strong> rock<br />

to be consistent with <strong>the</strong> known bedrock geology in <strong>the</strong> region. Figure 11-6,<br />

Location of Telegraph Hill and Historic Shoreline, is a plan of <strong>the</strong> South <strong>Boston</strong><br />

Area illustrating that a portion of South <strong>Boston</strong> is occupied by Telegraph Hill.<br />

Telegraph Hill is considered a drumlin (Skehan, 2001) consisting of a bedrock<br />

high mantled with till. Kaye (1976) indicates that <strong>the</strong> surface of <strong>the</strong> bedrock is<br />

high near <strong>the</strong> top of Telegraph Hill and <strong>the</strong>n drops off quickly away from<br />

Telegraph Hill to <strong>the</strong> east and west. Previous seismic and geotechnical<br />

11.0 Geotechnical Impact 11-5


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

investigations indicate that <strong>the</strong> bedrock surface is 40 to 50 feet bgs near <strong>the</strong><br />

intersection of Columbia Road and Damrell just south of Telegraph Hill. Directly<br />

to <strong>the</strong> east of Telegraph Hill, <strong>the</strong>re appears to be a bedrock valley that has been<br />

filled with till and glacial outwash deposits. Very thin and discontinuous marine<br />

clay deposits have been encountered in this filled valley area.<br />

Like many regions in <strong>Boston</strong>, areas encircling Telegraph Hill are filled land<br />

with a typical stratigraphic sequence of fill, thin discontinuous sand deposits,<br />

organic silt and clay, marine clay, and till overlying <strong>the</strong> bedrock. As shown on<br />

Figure 11-6, <strong>the</strong> project site is located at <strong>the</strong> edge of <strong>the</strong> natural shoreline as it<br />

existed in 1630. Figure 11-7, Historic Shoreline, shows historic shoreline as<br />

of 1868 and indicates that approximately <strong>the</strong> nor<strong>the</strong>rn third of <strong>the</strong> site is<br />

beyond <strong>the</strong> shoreline at that time. Sanborn map of 1888, shown as Figure 11-<br />

8, indicates that a dock was present at <strong>the</strong> northwest corner of <strong>the</strong> site.<br />

Considering <strong>the</strong> local geology, site topography, evaluation of <strong>the</strong> historic<br />

shoreline, and <strong>the</strong> subsurface conditions encountered at <strong>the</strong> borings, <strong>the</strong><br />

sou<strong>the</strong>rn half of <strong>the</strong> site appears to be located on <strong>the</strong> edge of <strong>the</strong> Telegraph<br />

Hill drumlin thus underlain by till (consistent with materials encountered at<br />

borings WB-1 and WB-7). The nor<strong>the</strong>rn side of <strong>the</strong> site is situated on filled<br />

land thus fill is anticipated above <strong>the</strong> natural deposit (consistent with materials<br />

encountered at borings WB-3 2 , WB-4, WB-5, and WB-6). WB-2 is located<br />

within <strong>the</strong> existing warehouse and <strong>the</strong> historic fill was probably removed as<br />

part of <strong>the</strong> construction of <strong>the</strong> warehouse. Given <strong>the</strong> presence of <strong>the</strong> dock and<br />

<strong>the</strong> expansion of <strong>the</strong> shoreline since late 1800’s, it is also anticipated that large<br />

granite blocks are present below <strong>the</strong> nor<strong>the</strong>rn portion of <strong>the</strong> site. Granite<br />

blocks are commonly used as seawalls and are generally not removed as <strong>the</strong><br />

shoreline expands. Exact configuration and locations of <strong>the</strong> seawall at this site<br />

are unknown due to limited information obtained for this project.<br />

Never<strong>the</strong>less, <strong>the</strong> presence of <strong>the</strong> seawalls is likely and is considered<br />

obstructions for <strong>the</strong> underground structures, if encountered.<br />

2 WB-2 is located within <strong>the</strong> existing warehouse and <strong>the</strong> historic fill was probably removed as part of <strong>the</strong> construction of<br />

<strong>the</strong> warehouse.<br />

11.0 Geotechnical Impact 11-6


11.4 Groundwater<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Depth to groundwater at <strong>the</strong> seven borings observed during <strong>the</strong> site<br />

investigation program ranged from approximately El. 9.5 to El. 17.5, with an<br />

average groundwater elevation of El.12.0 feet. Groundwater measurements<br />

made during <strong>the</strong> field program are tabulated in Table 11-1. Given <strong>the</strong><br />

proximity of <strong>the</strong> site to <strong>the</strong> Reserved Channel, it should be expected that<br />

groundwater levels might be subjected to variations due to tidal fluctuations as<br />

well as seasonal precipitation. It is recommended that readings be made prior<br />

to construction at <strong>the</strong> existing observation wells at <strong>the</strong> site to quantify <strong>the</strong> tidal<br />

and seasonal fluctuations in <strong>the</strong> groundwater level.<br />

11.5 Foundation Design Recommendations<br />

The proposed new structures at this site include four-story residential complex<br />

as indicated in <strong>the</strong> Architectural Drawings (Chapter 7). The geotechnical<br />

concerns for this site are potential building differential settlements and<br />

minimizing groundwater movements. Groundwater flow is of concern since<br />

<strong>the</strong> owner has indicated that within a relatively confined section near <strong>the</strong><br />

northwestern corner of <strong>the</strong> site, known contaminant was encountered. Due to<br />

<strong>the</strong> presence of known contaminant, it is recommended that special<br />

precautions should be followed during construction to minimize groundwater<br />

flow that may potentially induce <strong>the</strong> movement of <strong>the</strong> contaminants as well as<br />

disposal of excavated material and decontamination of <strong>the</strong> equipment that<br />

came in contact with <strong>the</strong> contaminant.<br />

Groundwater measurements obtained during <strong>the</strong> boring program consistently<br />

show <strong>the</strong> groundwater level below <strong>the</strong> final proposed top of slab. Additional<br />

groundwater readings should be made at <strong>the</strong> existing observation wells to<br />

verify <strong>the</strong> groundwater level relative to <strong>the</strong> slab grade accounting for tidal and<br />

seasonal fluctuations. This information should be obtained prior to<br />

construction as it may impact <strong>the</strong> construction sequence, extent, method, and<br />

schedule of <strong>the</strong> building foundation.<br />

11.0 Geotechnical Impact 11-7


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Based on borings and <strong>the</strong> site geology, 2 subsurface conditions exist at <strong>the</strong><br />

site: (A) profile with sand and till and (B) profile with clay. Foundation<br />

recommendations for <strong>the</strong>se 2 profiles are presented below:<br />

Profile A<br />

Along Dorchester Street south of Boring WB-2 and WB-6, <strong>the</strong> new building is<br />

likely to be founded on <strong>the</strong> sand or till (sand and gravel). Based on visual<br />

classification, <strong>the</strong> underlying sand and till can be classified as Material Class 7<br />

or 8 in accordance with <strong>the</strong> 6th edition of <strong>the</strong> Massachusetts State Building<br />

Code (MSBC, Table 1804). The N-value for <strong>the</strong> sand and till layer is<br />

generally above 35 blows/ft indicating <strong>the</strong> material to be dense to very dense.<br />

It is recommended that spread footing foundations with maximum allowable<br />

bearing pressure of 4 tons/ft 2 be used on <strong>the</strong> dense sand and till. The bottom of<br />

<strong>the</strong> footing should extend 4-ft below <strong>the</strong> final grade for frost protection with a<br />

minimum width of 3-ft. For footing width of 2-ft, <strong>the</strong> maximum allowable<br />

bearing pressure is 3 tons/ft 2 . The estimated settlement for loading within <strong>the</strong><br />

allowable bearing stated above is less than 0.3”. If <strong>the</strong> till is not encountered at<br />

a depth of 4-ft at footing locations, <strong>the</strong> existing miscellaneous fill should be<br />

excavated to an additional depth of 4 feet or to top of sand or till, whichever is<br />

less, and replaced with compacted structural fill. However, should conditions<br />

require excavation to or below <strong>the</strong> elevation of <strong>the</strong> bottom of <strong>the</strong> footing, <strong>the</strong><br />

engineer should be informed and site visit by <strong>the</strong> engineer should be made to<br />

provide recommendations based on actual conditions encountered prior to <strong>the</strong><br />

contractor proceeding. Structural fill should be placed in 9” loose lifts with<br />

each successive lift compacted to a density of not less than 95 percent of <strong>the</strong><br />

maximum as determined by ASTM D1557. Recommended material gradation<br />

for structural fill and gravel borrow base course is shown in Table 11-2.<br />

Permanent retaining walls and temporary support of excavation walls should<br />

be designed to sustain <strong>the</strong> lateral earth and water pressures shown on Figure<br />

11-9. For <strong>the</strong> permanent retaining wall design, it should be assumed that <strong>the</strong><br />

11.0 Geotechnical Impact 11-8


Table 11-2 Recommended Material Gradation<br />

Sieve Size Percent Finer by Weight<br />

4-inch 100<br />

½ inch 50 – 85<br />

No. 4 40 – 75<br />

No. 10 10 – 35<br />

No. 100 5 – 20<br />

No. 200 2 - 10<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

groundwater elevation is 2-ft above <strong>the</strong> top of base slab. This assumed<br />

groundwater level is significantly higher than <strong>the</strong> actual condition and is only<br />

applicable for <strong>the</strong> design of permanent retaining wall. For <strong>the</strong> design of o<strong>the</strong>r<br />

building components, <strong>the</strong> actual groundwater level, which is few feet below<br />

<strong>the</strong> final grade, should be used.<br />

Profile B<br />

Along East First Street, north of Boring WB-2 and WB-6, fill and clay is<br />

likely to be present below <strong>the</strong> new building. Based on visual classification, <strong>the</strong><br />

underlying clay can be classified as Material Class 10 accordance with <strong>the</strong> 6th<br />

edition of <strong>the</strong> Massachusetts State Building Code (MSBC, Table 1804). The<br />

N-value for <strong>the</strong> clay layer is generally above 6 blows/ft with <strong>the</strong> top 10-ft of<br />

<strong>the</strong> clay stratum with N-values above 10 blows/ft indicating <strong>the</strong> material to be<br />

stiff at <strong>the</strong> top and medium stiff below. It is recommended that spread footing<br />

foundations with maximum allowable bearing pressure of 2 tons/ft 2 be used<br />

on <strong>the</strong> stiff to medium stiff clay. The bottom of <strong>the</strong> footing should extend 4-ft<br />

below <strong>the</strong> final grade for frost protection with a minimum width of 3-ft. For<br />

footing width of 2-ft, <strong>the</strong> maximum allowable bearing pressure is 1.5 tons/ft 2 .<br />

The estimated settlement for loading within <strong>the</strong> allowable bearing stated<br />

above is less than 0.75”. It is likely that <strong>the</strong> clay will not be encountered at a<br />

depth of 4-ft at footing locations in this area; in this case, <strong>the</strong> existing<br />

miscellaneous fill should be excavated to an additional depth of 4 feet or to<br />

11.0 Geotechnical Impact 11-9


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

top of clay and replaced with compacted structural fill. However, should<br />

conditions require excavation to or below <strong>the</strong> elevation of <strong>the</strong> bottom of <strong>the</strong><br />

footing, <strong>the</strong> engineer should be informed and site visit by <strong>the</strong> engineer should<br />

be made to provide recommendations based on actual conditions encountered<br />

prior to <strong>the</strong> contractor proceeding. Structural fill should be placed in 9” loose<br />

lifts with each successive lift compacted to a density of not less than 95<br />

percent of <strong>the</strong> maximum as determined by ASTM D1557. The material<br />

gradation structural fill specified above should be used. In this case, <strong>the</strong><br />

required over-excavation may extend below <strong>the</strong> water table. In this case,<br />

efforts should be made to minimize inducing additional groundwater flow thus<br />

potentially cause movement in <strong>the</strong> contaminant. In <strong>the</strong> vicinity of Boring WB-<br />

4, it may be necessary to over-excavate well below <strong>the</strong> water table due to <strong>the</strong><br />

presence of a pocket of very loose fill (N-value of 2 blows/ft) encountered at<br />

WB-4. At o<strong>the</strong>r locations, <strong>the</strong> required over-excavation appear to be limited to<br />

4-ft as <strong>the</strong> existing fill appear to consist of acceptable material and density. In<br />

this area, <strong>the</strong> engineer must make a site visit and assess <strong>the</strong> actual conditions<br />

in order to provide appropriate recommendations based on <strong>the</strong> conditions<br />

encountered. If additional load bearing capacity is required, <strong>the</strong> use of helical<br />

piles or H-piles may be considered. Drilled-in piers, drilled shafts, or minipiles<br />

are not recommended due to <strong>the</strong> known presence of contaminants a <strong>the</strong><br />

northwest corner of <strong>the</strong> site.<br />

Based on existing borings, <strong>the</strong> exact location of <strong>the</strong> transition from Profile A<br />

to Profile B is unknown and <strong>the</strong> exact location of transition can only be<br />

identified after commencement of <strong>the</strong> construction and as part of <strong>the</strong><br />

foundation work.<br />

The temporary earth support for construction of <strong>the</strong>se retaining walls and<br />

foundation elements should be designed by <strong>the</strong> contractor to prevent damage<br />

to adjacent structure including existing utilities, roadways, and buildings.<br />

11.0 Geotechnical Impact 11-10


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Based on <strong>the</strong> soil and corresponding N-values encountered at <strong>the</strong> site, <strong>the</strong> soils<br />

at <strong>the</strong> site is not susceptible to liquefaction.<br />

11.6 Seismic Design<br />

Based on <strong>the</strong> results of <strong>the</strong> site investigation program, soil Profile A (sou<strong>the</strong>rn<br />

part of <strong>the</strong> site) at this site can be categorized as type S1, with a site<br />

coefficient of 1.0 and soil Profile B (nor<strong>the</strong>rn part of <strong>the</strong> site) can be<br />

categorized as type S2 with site coefficient of 1.2 (Table 1612.4.1, 780 CMR:<br />

Massachusetts State Building Code, 6th Edition).<br />

11.7 Construction considerations<br />

The site is located close to <strong>the</strong> historic shoreline with sou<strong>the</strong>rn half of <strong>the</strong> site<br />

on till and <strong>the</strong> nor<strong>the</strong>rn half on clay and fill. Based on <strong>the</strong> historic shoreline<br />

and <strong>the</strong> historic use of <strong>the</strong> site, it is anticipated that granite blocked seawall are<br />

present below <strong>the</strong> nor<strong>the</strong>rn half of <strong>the</strong> site. The exact location and <strong>the</strong><br />

configuration of <strong>the</strong> seawalls are unknown and <strong>the</strong>y are potentially<br />

obstructions for <strong>the</strong> proposed underground work. Specific recommendations<br />

for <strong>the</strong> seawalls cannot be provided at this time since <strong>the</strong> most appropriate<br />

measure would depend on <strong>the</strong> final structure and <strong>the</strong> actual condition<br />

encountered. It is recommended that <strong>the</strong> contractor and <strong>the</strong> engineer are aware<br />

of this condition prior to construction thus are prepared to address this if<br />

seawalls are encountered.<br />

As indicated in <strong>the</strong> previous sections, <strong>the</strong> owner has indicated that <strong>the</strong>re are<br />

environmental issues at <strong>the</strong> northwest corner of <strong>the</strong> site. Since environmental<br />

services are beyond <strong>the</strong> scope of our work, specific recommendations cannot<br />

be provided with regards to <strong>the</strong> treatment and disposal of <strong>the</strong> material.<br />

However, it is recommended that pumping of groundwater be avoided in<br />

order to minimize <strong>the</strong> potential to induce movements of <strong>the</strong><br />

contaminant. Excavated material should also be tested so <strong>the</strong>y can be<br />

properly disposed. If dewatering cannot be avoided, it is recommended<br />

11.0 Geotechnical Impact 11-11


References<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

that sheetpiles bounding <strong>the</strong> site be installed in order to minimize flow<br />

into <strong>the</strong> site in response to <strong>the</strong> pumping.<br />

Skehan, J.W., 2001. Roadside Geology of Massachusetts. Missoula,<br />

Montana: Mountain Press Publishing Company.<br />

Kaye, C.A., 1976. The Geology and Early History of <strong>the</strong> <strong>Boston</strong> Area of<br />

Massachusetts: a bicentennial approach: <strong>the</strong> role of geology in <strong>the</strong> important<br />

events that took place around <strong>Boston</strong> 200 years ago, Geological Survey<br />

Bulletin; 1476, Washington: U.S. Government Printing Office.<br />

11.0 Geotechnical Impact 11-12


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 11-1 Site Location<br />

Figure 11-2<br />

Project Site Aerial Photograph<br />

11.0 Geotechnical Impact 11-13


Figure 11-3 Boring Location Plan<br />

Figure 11-4 Subsurface Profile<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

11.0 Geotechnical Impact 11-14


Figure 11-5 Bedrock Geology Map of <strong>the</strong> <strong>Boston</strong> Area<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

11.0 Geotechnical Impact 11-15


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Figure 11-6, Location of Telegraph Hill and Historic Shoreline<br />

Figure 11-7, Historic Shoreline of 1868<br />

11.0 Geotechnical Impact 11-16


Figure 11-8, 1888 Sanborn Map<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

11.0 Geotechnical Impact 11-17


Figure 11-9 Lateral Earth Pressures<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

11.0 Geotechnical Impact 11-18


Table 11-3 Boring Table<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

11.0 Geotechnical Impact 11-19


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

11.0 Geotechnical Impact 11-20


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

11.0 Geotechnical Impact 11-21


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

11.0 Geotechnical Impact 11-22


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

11.0 Geotechnical Impact 11-23


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

11.0 Geotechnical Impact 11-24


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

11.0 Geotechnical Impact 11-25


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

11.0 Geotechnical Impact 11-26


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

11.0 Geotechnical Impact 11-27


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

11.0 Geotechnical Impact 11-28


12.0 ENVIRONMENTAL IMPACTS<br />

12.1 Article 37<br />

12.2 Wind<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The intention of this project from <strong>the</strong> outset has been to set new standards for<br />

sustainable design, construction and use of residential and associated mixed uses<br />

in an inner city location. In addition to <strong>the</strong> foregoing description of <strong>the</strong> project<br />

components and in compliance with Article 80B-3.2, <strong>the</strong> Environmental<br />

Protection Component of Article 80, <strong>the</strong> proponent has analyzed <strong>the</strong> project for<br />

compliance with <strong>the</strong> newly adopted regulations. This analysis is presented in<br />

Appendix 12-1 (Article 37 Project Checklist and Appendix 12-2 (LEED NC<br />

Checklist). The project scores 65 points out of a possible 73 on <strong>the</strong> Article 37<br />

checklist and 60 points out of a possible 69 on <strong>the</strong> LEED NC checklist.<br />

The proposed development is flanked by low rise buildings to <strong>the</strong> north and east<br />

(East First Street and H Street) and by low to medium rise residential<br />

development to <strong>the</strong> south and west (East Second Street and Dorchester Street. The<br />

annual prevailing wind is from <strong>the</strong> north-west (315 o ), principally a phenomenon<br />

of <strong>the</strong> winter months. In spring and fall <strong>the</strong> wind tends to veer from southwest<br />

(225 o ) to northwest (315 o ). In summer <strong>the</strong>se patterns are to a certain extent<br />

conditioned by on-shore and off-shore breezes. In any of <strong>the</strong>se conditions <strong>the</strong> new<br />

development is likely to prove an asset in providing something of a windbreak to<br />

<strong>the</strong> Second Street neighborhood frontage opposite and is unlikely to cause<br />

turbulence in any area – except possibly <strong>the</strong> courtyard within <strong>the</strong> development<br />

itself. This potential effect is mitigated by <strong>the</strong> open exposure to sunshine even<br />

during <strong>the</strong> winter months.<br />

12.0 Environmental Impacts 12-1


Figure 12-1 Prevailing winds (annual)<br />

Figure 12-2 Prevailing winds (monthly)<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

12.0 Environmental Impacts 12-2


Figure 12-3 Prevailing Wind diagram<br />

12.3 Shadow<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The shadow diagrams shown in Figure 12-4 illustrate sun and shadow conditions<br />

in Summer (June 21 st ), Equinox (March 21 st and September 21 st ) and Winter<br />

(December 21 st ) at 9am, noon, 3pm and 6pm (as appropriate). The massing of <strong>the</strong><br />

proposed development ensures that every part of <strong>the</strong> new buildings is exposed to<br />

direct sunlight for a significant period of <strong>the</strong> day in all seasons. The sou<strong>the</strong>ast<br />

elevation of <strong>the</strong> Dorchester Street block is at <strong>the</strong> outer limit of <strong>the</strong> shadow line<br />

caused by <strong>the</strong> Distillery building at 9am in December. Likewise, <strong>the</strong> existing<br />

Distillery and Warehouse buildings are not affected by <strong>the</strong> new development<br />

except in late afternoon in December.<br />

Outside <strong>the</strong> site, <strong>the</strong>re is no significant overshadowing on 1 st Street, H Street and<br />

2 nd Street. On Dorchester Street <strong>the</strong>re is some overshadowing of proposed new<br />

housing on <strong>the</strong> opposite side of <strong>the</strong> street on winter mornings (9:00am). From<br />

about 1:30 0nwrds <strong>the</strong> street receives direct sunlight.<br />

12.0 Environmental Impacts 12-3


12.4 Daylight<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Every unit in <strong>the</strong> new development is illuminated with natural light. Window head<br />

heights are typically 8’-0” or more to maximize <strong>the</strong> penetration of natural light<br />

into <strong>the</strong> center of <strong>the</strong> apartments. The residential apartments have been designed<br />

to be exceptionally deep (75 feet from front to back) in order minimize <strong>the</strong> ratio<br />

of building enclosure to enclosed floor area. In order to bring natural light into <strong>the</strong><br />

center of <strong>the</strong> apartment a lightwell is located in between <strong>the</strong> pairs of units. The<br />

natural light is augmented by heliostats, mirrors designed to track <strong>the</strong> sun<br />

throughout <strong>the</strong> day focusing down on a fixed target within <strong>the</strong> atrium.<br />

The live-work studio units are less deep from front to back (56 feet) and are<br />

served by tall windows on each elevation with <strong>the</strong> purpose of bringing natural<br />

light into <strong>the</strong> center of <strong>the</strong> units.<br />

The location of <strong>the</strong> new development in relation to <strong>the</strong> surrounding neighborhood<br />

is such that <strong>the</strong> only shadowing is across Dorchester Street in <strong>the</strong> early morning.<br />

There will be no significant diminution of natural light.<br />

12.5 Solar Glare<br />

The building envelope of <strong>the</strong> new development is principally non-reflective<br />

consisting of masonry on <strong>the</strong> exterior facades and wood on <strong>the</strong> inner courtyard<br />

facades. The elevations of <strong>the</strong> building most directly hit by <strong>the</strong> sun will also be<br />

shaded so that <strong>the</strong> sun will not be hitting glass windows for any significant<br />

amount of time causing annoyance with reflection. The roof is landscaped<br />

throughout and will <strong>the</strong>refore be non-reflective.<br />

12.6 Air Quality<br />

It is expected that <strong>the</strong> air quality impact of this development will be significantly<br />

less than that of projects comparable in size and scope. The primary goals of <strong>the</strong><br />

project are to minimize energy use and <strong>the</strong> use of fossil fuels, minimize<br />

environmental impact and promote health. The use of vegetable oil for <strong>the</strong><br />

12.0 Environmental Impacts 12-4


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

cogeneration plant and <strong>the</strong> promotion of plug-in hybrid vehicles are examples of<br />

this intention. These goals and o<strong>the</strong>r objectives are outlined in Chapter 1.<br />

12.7 Water Quality<br />

It is expected that <strong>the</strong>re will be no negative water quality impacts from <strong>the</strong><br />

proposed project. The development of <strong>the</strong> site will reduce <strong>the</strong> area of impervious<br />

surfaces and retention and re-use of stormwater is part of <strong>the</strong> project program. As<br />

part of <strong>the</strong> Health objective (see Chapter 1) protocols for <strong>the</strong> use of non-toxic<br />

cleaning agents, fertilizers sprays and packaging for maintenance and operations<br />

will be developed and adhered to. The safe disposal of toxic materials used by<br />

artists are, and will continue to be, fully compliant with current regulations.<br />

12.0 Environmental Impacts 12-5


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Chapter 12 ENVIRONMENTAL IMPACT - APPENDICES<br />

APPENDIX 12-1 Article 37 Project Checklist<br />

BOSTON GREEN BUILDING CREDITS 4 Possible Points<br />

Credit 1 Modern Grid<br />

The proposed project will generate near to 100% of all energy required for <strong>the</strong><br />

occupants, buildings and infrastructure with renewable fuel. A combustion<br />

engine driven, distributed generation/combined heat and power system that is<br />

fueled with vegetable oil is proposed.<br />

Credit 2 Historic Preservation<br />

Not applicable to this project.<br />

Credit 3 Groundwater Recharge<br />

The proposed Distillery <strong>Redevelopment</strong> will meet <strong>the</strong> requirements.<br />

Credit 4 Modern Mobility<br />

The proposed Distillery <strong>Redevelopment</strong> will meet <strong>the</strong> requirements.<br />

Alternative transportation is a major component of <strong>the</strong> project as outline in <strong>the</strong><br />

Transportation Mitigation and Improvement Plan - Section 9.6.<br />

SUSTAINABLE SITES 14 Possible Points<br />

Prereq 1 Construction Activity Pollution Prevention<br />

An Erosion and Sedimentation Control (ESC) Plan will be created and<br />

implemented for all construction activities associated with <strong>the</strong> project. All<br />

elements of <strong>the</strong> project will also comply with Phase I and Phase II of <strong>the</strong><br />

National Pollutant Discharge Elimination System (NPDES) program.<br />

Credit 1 Site Selection<br />

The Distillery <strong>Redevelopment</strong> Site meets <strong>the</strong> requirements.<br />

Credit 2 Development Density & Community Connectivity<br />

The proposed Distillery <strong>Redevelopment</strong> meets <strong>the</strong> requirements.<br />

Credit 3 Brownfield <strong>Redevelopment</strong><br />

The Distillery <strong>Redevelopment</strong> Site meets <strong>the</strong> requirements.<br />

Credit 4.1 Alternative Transportation, Public Transportation Access<br />

Currently, <strong>the</strong> closest public transportation is <strong>the</strong> No. 9 bus on East Broadway<br />

and H Street, three blocks away. O<strong>the</strong>r bus and subway services are not<br />

within <strong>the</strong> required distance of <strong>the</strong> site. A preliminary discussion with <strong>the</strong><br />

12.0 Environmental Impacts 12-6


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

MBTA indicated a willingness to continue looking at service modifications<br />

that may bring a second bus stop to within ¼ mile.<br />

Credit 4.2 Alternative Transportation, Bicycle Storage & Changing Rooms<br />

The proposed Distillery <strong>Redevelopment</strong> meets <strong>the</strong> requirements.<br />

Credit 4.3 Alternative Transportation, Low Emitting & Fuel Efficient Vehicles<br />

The proposed Distillery <strong>Redevelopment</strong> meets <strong>the</strong> requirements. Alternative<br />

transportation is a major component of <strong>the</strong> project as outline in <strong>the</strong><br />

Transportation Mitigation and Improvement Plan - Section 9.6.<br />

Credit 4.4 Alternative Transportation, Parking Capacity<br />

The proposed Distillery <strong>Redevelopment</strong> meets <strong>the</strong> requirements. Alternative<br />

transportation is a major component of <strong>the</strong> project as outline in <strong>the</strong><br />

Transportation Mitigation and Improvement Plan - Section 9.6.<br />

Credit 5.1 Site Development, Protect or Restore Habitat<br />

The proposed Distillery <strong>Redevelopment</strong> will restore a minimum of 50% of <strong>the</strong><br />

site area (excluding <strong>the</strong> building footprint) with native or adapted vegetation.<br />

Credit 5.2 Site Development, Maximize Open Space<br />

The proposed Distillery <strong>Redevelopment</strong> will provide vegetated open space<br />

greater than 20% of <strong>the</strong> project’s site area.<br />

Credit 6.1 Stormwater Design, Quantity Control<br />

The proposed Distillery <strong>Redevelopment</strong> will use highly sustainable<br />

Stormwater Management programs that will meet <strong>the</strong> requirements.<br />

Credit 6.2 Stormwater Design, Quality Control<br />

The proposed Distillery <strong>Redevelopment</strong> will use highly sustainable<br />

Stormwater Management programs that will meet <strong>the</strong> requirements.<br />

Credit 7.1 Heat Island Effect, Non-Roof<br />

The proposed Distillery <strong>Redevelopment</strong> will have 100% underground parking.<br />

Credit 7.2 Heat Island Effect, Roof<br />

The proposed Distillery <strong>Redevelopment</strong> will use a high albedo and vegetated<br />

roof surfaces that, in combination, will meet <strong>the</strong> requirements.<br />

Credit 8 Light Pollution Reduction<br />

The proposed Distillery <strong>Redevelopment</strong> meets <strong>the</strong> requirements.<br />

WATER EFFICIENCY 5 Possible Points<br />

Credit 1.1 Water Efficient Landscaping, Reduce by 50%<br />

12.0 Environmental Impacts 12-7


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The proposed Distillery <strong>Redevelopment</strong> will use only captured rainwater for<br />

landscape irrigation.<br />

Credit 1.2 Water Efficient Landscaping, No Potable Use or No Irrigation<br />

The proposed Distillery <strong>Redevelopment</strong> will use only captured rainwater for<br />

landscape irrigation.<br />

Credit 2 Innovative Wastewater Technologies<br />

Not determined at this time.<br />

Credit 3.1 Water Use Reduction, 20% Reduction<br />

Not determined at this time.<br />

Credit 3.2 Water Use Reduction, 30% Reduction<br />

Not determined at this time.<br />

ENERGY & ATMOSPHERE 17 Possible Points<br />

Prereq 1 Fundamental Commissioning of <strong>the</strong> Building Energy Systems Required<br />

The proposed Distillery <strong>Redevelopment</strong> buildings and systems will be fully<br />

commissioned.<br />

Prereq 2 Minimum Energy Performance Required<br />

Energy conservation measures will be an integral part of <strong>the</strong> project’s<br />

infrastructure design with expected energy cost savings exceeding 50% of<br />

baseline.<br />

Prereq 3 Fundamental Refrigerant Management Required<br />

No CFC-based refrigerants will be used in <strong>the</strong> building HVAC&R systems.<br />

Credit 1 Optimize Energy Performance<br />

10 credits. Energy conservation measures will be an integral part of <strong>the</strong><br />

project’s infrastructure design with expected energy cost savings exceeding<br />

50% of baseline.<br />

Credit 2 On-Site Renewable Energy<br />

3 credits. The proposed project will generate near to 100% of all energy<br />

required for <strong>the</strong> occupants, buildings and infrastructure with renewable fuel.<br />

Credit 3 Enhanced Commissioning<br />

The proposed Distillery <strong>Redevelopment</strong> buildings and systems will be fully<br />

commissioned and meet this requirement.<br />

Credit 4 Enhanced Refrigerant Management<br />

The proposed Distillery <strong>Redevelopment</strong> project will not use refrigerants.<br />

12.0 Environmental Impacts 12-8


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Credit 5 Measurement & Verification<br />

Building energy consumption will be measured and verified for no less than<br />

one year of post-construction occupancy.<br />

Credit 6 Green Power<br />

The proposed project will generate near to 100% of all energy required for <strong>the</strong><br />

occupants, buildings and infrastructure with renewable fuel.<br />

MATERIALS & RESOURCES 13 Possible Points<br />

Prereq 1 Storage & Collection of Recyclables Required<br />

The proposed Distillery <strong>Redevelopment</strong> meets <strong>the</strong> requirements.<br />

Credit 1.1 Building Reuse, Maintain 75% of Existing Walls, Floors & Roof<br />

<br />

Credit 1.2 Building Reuse, Maintain 95% of Existing Walls, Floors & Roof<br />

<br />

Credit 1.3 Building Reuse, Maintain 50% of Interior Non-Structural Elements<br />

<br />

Credit 2.1 Construction Waste Management, Divert 50% from Disposal 1<br />

This requirement will be included in construction contracts.<br />

Credit 2.2 Construction Waste Management, Divert 75% from Disposal 1<br />

This requirement will be included in construction contracts.<br />

Credit 3.1 Materials Reuse, 5%<br />

This requirement will be included in construction documents and contracts.<br />

Credit 3.2 Materials Reuse, 10%<br />

This requirement will be included in construction documents and contracts.<br />

Credit 4.1 Recycled Content, 10% (post-consumer + 1/2 pre-consumer)<br />

This requirement will be included in construction contracts.<br />

Credit 4.2 Recycled Content, 20% (post-consumer + 1/2 pre-consumer)<br />

Not determined at this time.<br />

Credit 5.1 Regional Materials, 10% Extracted, Processed & Manufactured Regionally<br />

This requirement will be included in construction contracts.<br />

Credit 5.2 Regional Materials, 20% Extracted, Processed & Manufactured Regionally<br />

Not determined at this time.<br />

12.0 Environmental Impacts 12-9


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Credit 6 Rapidly Renewable Materials<br />

This requirement will be included in construction contracts.<br />

Credit 7 Certified Wood<br />

This project will use a minimum of 50% of wood-based materials and<br />

products, which are certified in accordance with <strong>the</strong> Forest Stewardship<br />

Council’s (FSC) Principles and Criteria, for wood building components.<br />

INDOOR ENVIRONMENTAL QUALITY 15 Possible Points<br />

Prereq 1 Minimum IAQ Performance Required<br />

The proposed buildings will meet <strong>the</strong>se requirements.<br />

Prereq 2 Environmental Tobacco Smoke (ETS) Control Required<br />

The proposed buildings will meet <strong>the</strong>se requirements.<br />

Credit 1 Outdoor Air Delivery Monitoring<br />

Ventilation systems will be monitored and will meet <strong>the</strong>se requirements.<br />

Credit 2 Increased Ventilation<br />

Ventilation systems will be designed to meet <strong>the</strong>se requirements.<br />

Credit 3.1 Construction IAQ Management Plan, During Construction<br />

An Indoor Air Quality (IAQ) Management Plan for <strong>the</strong> construction and preoccupancy<br />

phases of <strong>the</strong> building will be developed and implemented to meet<br />

<strong>the</strong>se requirements.<br />

Credit 3.2 Construction IAQ Management Plan, Before Occupancy<br />

An Indoor Air Quality (IAQ) Management Plan for <strong>the</strong> construction and preoccupancy<br />

phases of <strong>the</strong> building will be developed and implemented to meet<br />

<strong>the</strong>se requirements.<br />

Credit 4.1 Low-Emitting Materials, Adhesives & Sealants<br />

This requirement will be included in specifications, construction documents<br />

and contracts.<br />

Credit 4.2 Low-Emitting Materials, Paints & Coatings<br />

This requirement will be included in specifications, construction documents<br />

and contracts.<br />

Credit 4.3 Low-Emitting Materials, Carpet Systems<br />

This requirement will be included in specifications, construction documents<br />

and contracts.<br />

Credit 4.4 Low-Emitting Materials, Composite Wood & Agrifiber Products<br />

12.0 Environmental Impacts 12-10


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

This requirement will be included in specifications, construction documents<br />

and contracts.<br />

Credit 5 Indoor Chemical & Pollutant Source Control<br />

The proposed buildings will meet <strong>the</strong>se requirements.<br />

Credit 6.1 Controllability of Systems, Lighting<br />

The proposed buildings will meet <strong>the</strong>se requirements.<br />

Credit 6.2 Controllability of Systems, Thermal Comfort<br />

The proposed buildings will meet <strong>the</strong>se requirements.<br />

Credit 7.1 Thermal Comfort, Design<br />

The proposed buildings will meet <strong>the</strong>se requirements.<br />

Credit 7.2 Thermal Comfort, Verification<br />

The buildings will undergo verification to meet <strong>the</strong>se requirements.<br />

Credit 8.1 Daylight & Views, Daylight 75% of Spaces<br />

The proposed buildings will meet <strong>the</strong>se requirements.<br />

Credit 8.2 Daylight & Views, Views for 90% of Spaces<br />

The proposed buildings will meet <strong>the</strong>se requirements.<br />

INNOVATION & DESIGN PROCESS 5 Possible Points<br />

Credit 1.1 Innovation in Design<br />

The project will use heliostats, natural air flow night venting, vegetable oil<br />

CHP, computer enabled ride-share systems, plug-in hybrid commuter vans,<br />

waterless urinals in public spaces, French-intensive rooftop Victory gardens as<br />

well as innovations in IAQ. It is expected that all 4 Innovation in Design<br />

Credits will be attained.<br />

Credit 1.2 Innovation in Design<br />

See above.<br />

Credit 1.3 Innovation in Design<br />

See above.<br />

Credit 1.4 Innovation in Design<br />

See above.<br />

Credit 2 LEED Accredited Professional<br />

Mark Kelley, P.E. of The Hickory Consortium is a principal participant of <strong>the</strong><br />

project team and is a LEED Accredited Professional.<br />

12.0 Environmental Impacts 12-11


APPENDIX 12-2 LEED NC CHECKLIST<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

LEED-NC Version 2.2 Registered Project Checklist<br />

The Distillery <strong>Redevelopment</strong><br />

South <strong>Boston</strong>, MA 02127<br />

Yes ? No<br />

13 1 Sustainable Sites 14 Points<br />

Y<br />

Prereq<br />

1 Construction Activity Pollution Prevention Required<br />

1 Credit<br />

1 Site Selection 1<br />

1 Credit<br />

2 Development Density & Community Connectivity 1<br />

1 Credit<br />

3 Brownfield <strong>Redevelopment</strong> 1<br />

1 Credit<br />

4.1 Alternative Transportation, Public Transportation Access 1<br />

1 Credit<br />

4.2<br />

Alternative Transportation, Bicycle Storage & Changing<br />

Rooms<br />

1<br />

1 Credit<br />

4.3<br />

Alternative Transportation, Low-Emitting and Fuel-Efficient<br />

Vehicles<br />

1<br />

1 Credit<br />

4.4 Alternative Transportation, Parking Capacity 1<br />

1 Credit<br />

5.1 Site Development, Protect or Restore Habitat 1<br />

1 Credit<br />

5.2 Site Development, Maximize Open Space 1<br />

1 Credit<br />

6.1 Stormwater Design, Quantity Control 1<br />

1 Credit<br />

6.2 Stormwater Design, Quality Control 1<br />

1 Credit<br />

7.1 Heat Island Effect, Non-Roof 1<br />

1 Credit<br />

7.2 Heat Island Effect, Roof 1<br />

1 Credit<br />

8 Light Pollution Reduction 1<br />

Yes ? No<br />

2 3 Water Efficiency 5 Points<br />

1 Credit<br />

1.1 Water Efficient Landscaping, Reduce by 50% 1<br />

1 Credit<br />

1.2<br />

Water Efficient Landscaping, No Potable Use or No<br />

Irrigation<br />

1 Credit<br />

2 Innovative Wastewater Technologies 1<br />

1 Credit<br />

3.1 Water Use Reduction, 20% Reduction 1<br />

1 Credit<br />

3.2 Water Use Reduction, 30% Reduction 1<br />

Yes ? No<br />

12.0 Environmental Impacts 12-12<br />

1


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

17 Energy & Atmosphere 17 Points<br />

Y<br />

Prereq<br />

1<br />

Fundamental Commissioning of <strong>the</strong> Building Energy<br />

Systems<br />

12.0 Environmental Impacts 12-13<br />

Required<br />

Y<br />

Prereq<br />

2 Minimum Energy Performance Required<br />

Y<br />

Prereq<br />

3 Fundamental Refrigerant Management Required<br />

10 Credit<br />

1 Optimize Energy Performance 1 to 10<br />

3 Credit<br />

2 On-Site Renewable Energy 1 to 3<br />

1 Credit<br />

3 Enhanced Commissioning 1<br />

1 Credit<br />

4 Enhanced Refrigerant Management 1<br />

1 Credit<br />

5 Measurement & Verification 1<br />

1 Credit<br />

6 Green Power 1<br />

Yes ? No<br />

continued…<br />

8 2 3 Materials & Resources 13 Points<br />

Y<br />

Prereq<br />

1 Storage & Collection of Recyclables Required<br />

1 Credit<br />

1.1<br />

Building Reuse, Maintain 75% of Existing Walls, Floors &<br />

1<br />

1<br />

Roof<br />

Credit<br />

1.2<br />

Building Reuse, Maintain 100% of Existing Walls, Floors &<br />

Roof<br />

1<br />

1 Credit<br />

1.3<br />

Building Reuse, Maintain 50% of Interior Non-Structural<br />

Elements<br />

1<br />

1 Credit<br />

2.1 Construction Waste Management, Divert 50% from Disposal 1<br />

1 Credit<br />

2.2 Construction Waste Management, Divert 75% from Disposal 1<br />

1 Credit<br />

3.1 Materials Reuse, 5% 1<br />

1 Credit<br />

3.2 Materials Reuse,10% 1<br />

1 Credit<br />

4.1 Recycled Content, 10% (post-consumer + ½ pre-consumer) 1<br />

1 Credit<br />

4.2 Recycled Content, 20% (post-consumer + ½ pre-consumer) 1<br />

1 Credit<br />

5.1<br />

Regional Materials, 10% Extracted, Processed &<br />

Manufactured Regionally<br />

1<br />

1 Credit<br />

5.2<br />

Regional Materials, 20% Extracted, Processed &<br />

Manufactured Regionally<br />

1<br />

1 Credit<br />

6 Rapidly Renewable Materials 1<br />

1 Credit<br />

7 Certified Wood 1<br />

Yes ? No<br />

15 Indoor Environmental Quality 15 Points<br />

Prereq<br />

Y<br />

1 Minimum IAQ Performance Required<br />

Y<br />

Prereq<br />

2 Environmental Tobacco Smoke (ETS) Control Required<br />

1 Credit<br />

1 Outdoor Air Delivery Monitoring 1


The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

1 Credit<br />

2 Increased Ventilation 1<br />

1 Credit<br />

3.1 Construction IAQ Management Plan, During Construction 1<br />

1 Credit<br />

3.2 Construction IAQ Management Plan, Before Occupancy 1<br />

1 Credit<br />

4.1 Low-Emitting Materials, Adhesives & Sealants 1<br />

1 Credit<br />

4.2 Low-Emitting Materials, Paints & Coatings 1<br />

1 Credit<br />

4.3 Low-Emitting Materials, Carpet Systems 1<br />

1 Credit<br />

4.4<br />

Low-Emitting Materials, Composite Wood & Agrifiber<br />

Products<br />

1 Credit<br />

5 Indoor Chemical & Pollutant Source Control 1<br />

1 Credit<br />

6.1 Controllability of Systems, Lighting 1<br />

1 Credit<br />

6.2 Controllability of Systems, Thermal Comfort 1<br />

1 Credit<br />

7.1 Thermal Comfort, Design 1<br />

1 Credit<br />

7.2 Thermal Comfort, Verification 1<br />

1 Credit<br />

8.1 Daylight & Views, Daylight 75% of Spaces 1<br />

1 Credit<br />

8.2 Daylight & Views, Views for 90% of Spaces 1<br />

Yes ? No<br />

5 Innovation & Design Process 5 Points<br />

1 Credit<br />

1.1 Innovation in Design: Provide Specific Title 1<br />

1 Credit<br />

1.2 Innovation in Design: Provide Specific Title 1<br />

1 Credit<br />

1.3 Innovation in Design: Provide Specific Title 1<br />

1 Credit<br />

1.4 Innovation in Design: Provide Specific Title 1<br />

1 Credit<br />

2 LEED ® Accredited Professional 1<br />

Yes ? No<br />

60 6 3 Project Totals (pre-certification estimates) 69 Points<br />

Certified 26-32 points Silver 33-38 points Gold 39-51 points Platinum 52-69 points<br />

12.0 Environmental Impacts 12-14<br />

1


6 AM 9 AM 12 PM 3 PM<br />

6 PM<br />

MAR 21<br />

JUN 21<br />

SEP 21<br />

DEC 21<br />

Figure 12-4 Shadow diagrams by season and time of day


13.0 CONSTRUCTION IMPACT<br />

13.1 Traffic<br />

See Chapter 9.7<br />

13.2 Air Quality<br />

13.3 Noise<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

Construction activities may generate fugitive dust resulting in a localized increase<br />

in airborne particles. Construction equipment with internal combustion engines<br />

will generate tailpipe emissions similar to those generated by highway trucks. To<br />

reduce fugitive dust and tailpipe emissions during construction a plan will be<br />

developed and incorporated into construction documents. Issues to be addressed<br />

include:<br />

• The use of wetting agents to suppress and control dust<br />

• Covering trucks transporting construction debris and materials<br />

• Regular cleaning of streets and sidewalks to minimize dust accumulation<br />

• Reduction of vehicle and equipment idling time<br />

• On-site monitoring of construction practices and impacts<br />

The proponent will include in all construction contracts <strong>the</strong> requirement that<br />

contractors observe city ordinances with regard to noise.<br />

The main sources of obtrusive noise are likely to be:<br />

• Demolition of existing structures<br />

• Excavation and driving sheet piles for construction of <strong>the</strong> basement<br />

13.0 Construction Impact 13-1


13.4 Rodent Control<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The proponent will employ <strong>the</strong> services of a rodent control consultant and<br />

operative to minimize <strong>the</strong> disruptive effects in <strong>the</strong> adjacent neighborhood of<br />

rodents displaced by construction.<br />

13.5 Wildlife Habitat<br />

There is no known wildlife habitat on site.<br />

13.6 Construction Management<br />

The proponent will comply with applicable state and local regulations covering<br />

construction impacts and will develop and be bound by a Construction<br />

Management Plan (CMP) developed in consultation with <strong>the</strong> <strong>Boston</strong><br />

Transportation Department and o<strong>the</strong>r City of <strong>Boston</strong> agencies as appropriate prior<br />

to <strong>the</strong> commencement of construction.<br />

The CMP will establish guidelines and specific mitigation methods and staging<br />

plans to minimize impacts to neighboring residents and property. An Erosion and<br />

Sedimentation Control (ESC) plan will be developed and implemented for all<br />

construction activities associated with <strong>the</strong> project. All elements of <strong>the</strong> project will<br />

also comply with Phase I and II of <strong>the</strong> National Pollutant Discharge Elimination<br />

System (NPDES) program.<br />

13.7 Monitoring<br />

The proponent will employ staff and equipment to comply with <strong>the</strong> mitigation<br />

measures outlined above and to carry out <strong>the</strong> Construction Management Plan, <strong>the</strong><br />

Erosion and Sedimentation Control Plan and o<strong>the</strong>r measures required for effective<br />

construction monitoring.<br />

13.0 Construction Impact 13-2


14.0 DESIGN REVIEW<br />

14.1 Community Meetings<br />

The Distillery <strong>Redevelopment</strong> | East Second Street | South <strong>Boston</strong><br />

The Distillery development is situated at <strong>the</strong> edge of <strong>the</strong> South <strong>Boston</strong><br />

neighborhood within five minutes walk of Broadway and will naturally be of<br />

great interest to neighbors and abutters and to <strong>the</strong> community at large. As a long<br />

term property owner in <strong>the</strong> area, <strong>the</strong> proponent has had <strong>the</strong> opportunity to build up<br />

lasting relationships and has employed local residents from time to time in <strong>the</strong><br />

operations and maintenance of <strong>the</strong> existing property. In addition to residents of<br />

<strong>the</strong> surrounding neighborhood <strong>the</strong>re are also residents in <strong>the</strong> existing Distillery<br />

buildings all of whom have a clear and distinct interest in <strong>the</strong> outcome of <strong>the</strong><br />

proposed development.<br />

The proponent has, during <strong>the</strong> course of developing this proposal, engaged a<br />

group of Distillery residents, engaging <strong>the</strong>m in discussions of what <strong>the</strong>y would<br />

like to see on <strong>the</strong> site and soliciting ideas in frequent meetings. The Article 80<br />

process is <strong>the</strong> time to communicate with <strong>the</strong> broader public through <strong>the</strong> Impact<br />

Advisory Group. The proponent will put resources forward for making <strong>the</strong> public<br />

meetings an opportunity for providing clear information and for receiving<br />

community input.<br />

14.2 <strong>Boston</strong> Civic Design Commission<br />

Under <strong>the</strong> terms of Section 80B-5.2 <strong>the</strong> Urban Design component of <strong>the</strong> proposed<br />

development is required to be submitted for review by <strong>the</strong> <strong>Boston</strong> Civic Design<br />

Commission. This submission contains all <strong>the</strong> required information for such<br />

review. For fur<strong>the</strong>r details in this regard refer to:<br />

Chapter 2 Program<br />

Chapter 3 Zoning<br />

Chapter 6 Urban Design<br />

Chapter 7 Architecture<br />

Chapter 8 Landscape Architecture<br />

14.0 Design Review 14-1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!