3000U USB Controller<br />

The 3000U controller has two LED status indicators.<br />

A green LED (D1) indicates controller status as follows:<br />

LED Blink Rate Function<br />

Once per second Normal condition, untouched state<br />

On continuously Touched state<br />

Twice per second Error detected<br />

A second LED (D6) indicates USB status as follows:<br />

LED State Function<br />

OFF Controller is not enumerated on USB<br />

ON Controller is enumerated on USB, but there is no data transfer<br />

Blinking USB data transfers between controller and host are occurring<br />

2201 PC-Bus Controller<br />

The E271-2201 PC-Bus controller has three diagnostic LED’s. Following<br />

power on, the controller performs its self-test. After the self-test, a flashing<br />

green LED indicates normal operation. If a fatal error was encountered, the<br />

yellow and red LED’s flash an eight-bit error code starting with the most<br />

significant bit, where yellow indicates a binary ‘0” and red a binary ‘1’. See the<br />

SmartSet Touchscreen Controller Family Technical Reference Manual<br />

available at www.elotouch.com/support/dwnldmnls.asp, or contact <strong>Elo</strong><br />

Technical Support for a list of error codes.<br />

During normal operation, the yellow LED indicates controller/host<br />

communication is in progress. For example, when the touchscreen is touched,<br />

the yellow LED should light or flicker (may not be visible with bus controllers<br />

on fast PC’s). If the host does not remove the packet from the controller, the<br />

LED will stay lit.<br />

If the yellow LED lights without a touch, the touchscreen or cabling may be<br />

shorted. Disconnect the touchscreen cable from the controller and cycle power<br />

to the controller to verify this condition.<br />

A constant red LED indicates a warning error condition, such as improper<br />

communication from the host. Suspect the baud rate or other communication<br />

parameters.<br />