KEY PROJECTS<br />

TALAVERA AND PALOMAREJO<br />

VA TECH <strong>HYDRO</strong> Madrid was awarded<br />

a contract for the complete supply<br />

(design, manufacture, erection,<br />

and commission<strong>in</strong>g) of four Semikaplan<br />

turb<strong>in</strong>es with a runner diameter<br />

of 2.85 m by the Iberdrola group.<br />

Cienersa, a company belong<strong>in</strong>g to the<br />

Iberdrola group, and dedicated to<br />

renewable energies and m<strong>in</strong>ihydro, is<br />

build<strong>in</strong>g two new power stations, Talavera<br />

and Palomarejo, both located <strong>in</strong> a<br />

city 120 km away from Madrid. Iberdrola<br />

is a Global Key Account of VA TECH<br />

<strong>HYDRO</strong>, and the lead<strong>in</strong>g utility <strong>in</strong><br />

<strong>in</strong>stalled hydropower <strong>in</strong> Spa<strong>in</strong>. The<br />

permanent collaboration of VA TECH<br />

<strong>HYDRO</strong> <strong>in</strong> Spa<strong>in</strong> with Iberdrola and<br />

their daughter companies this time has<br />

PORTODEMOUROS<br />

VA TECH <strong>HYDRO</strong> <strong>in</strong> Spa<strong>in</strong> has signed<br />

a contract with a subsidiary company<br />

of Union Fenosa for the supply of the<br />

electromechanical equipment for the<br />

extension of Portodemouros plant.<br />

Energias Especiales, Union Fenosa´s<br />

daughter company, dedicated to the renewable<br />

energies bus<strong>in</strong>ess, decided to<br />

<strong>in</strong>stall an additional hydraulic turb<strong>in</strong>e at<br />

its Portodemouros power plant, to use<br />

the tidal flow. Initially, this plant was<br />

equipped with two large vertical Francis<br />

turb<strong>in</strong>es, but this flow was by-passed<br />

when these large turb<strong>in</strong>es were out of service,<br />

with the consequent loss of energy.<br />

The design submitted by VA TECH <strong>HYDRO</strong><br />

<strong>in</strong> Spa<strong>in</strong> obta<strong>in</strong>ed the contract for the<br />

electromechanical equipment for this<br />

project. The plant is located <strong>in</strong> Galicia,<br />

14<br />

resulted <strong>in</strong> an order for the supply of<br />

four Semikaplan vertical turb<strong>in</strong>es,<br />

<strong>in</strong>clud<strong>in</strong>g the turb<strong>in</strong>e itself, control<br />

equipment, speed accelerator,<br />

generator, <strong>in</strong>let gates, and stop-logs.<br />

The same type of Semikaplan turb<strong>in</strong>es<br />

specially developed by VA TECH<br />

<strong>HYDRO</strong> <strong>in</strong> Spa<strong>in</strong> has been<br />

delivered before to the same client for<br />

other plants with satisfactory results.<br />

Tak<strong>in</strong>g advantage of the similar head<br />

and flow conditions of the two stations,<br />

the northwestern region of Spa<strong>in</strong> - recently<br />

known worldwide due to the<br />

Prestige accident - where Union<br />

Fenosa is the most important utility. The<br />

eng<strong>in</strong>eer<strong>in</strong>g and management of this<br />

project was entrusted to Soluziona<br />

Ingenieria, Union Fenosa´s eng<strong>in</strong>eer<strong>in</strong>g<br />

company, which has taken turnkey responsibility.<br />

The project presents specific<br />

difficulties, s<strong>in</strong>ce the erection work,<br />

and ma<strong>in</strong>ly the civil works and connection<br />

to the exist<strong>in</strong>g penstock, have to be<br />

made with the plant <strong>in</strong> service and<br />

therefore, the duration and schedul<strong>in</strong>g<br />

of downtimes are of vital importance to<br />

the customer. Follow<strong>in</strong>g these criteria,<br />

the proposal designed by VA TECH <strong>HYDRO</strong><br />

<strong>in</strong> Spa<strong>in</strong> is based on m<strong>in</strong>imiz<strong>in</strong>g these<br />

downtimes and reduc<strong>in</strong>g the head loss<br />

at the connection to the new branch<br />

with the exist<strong>in</strong>g penstock, us<strong>in</strong>g a design<br />

which shortens erection time and a<br />

project management which assures the<br />

coord<strong>in</strong>ation of the delivery dates of the<br />

different components to have them<br />

available just at the time they are required<br />

on site. Both approaches, de-<br />

located on the same river, the<br />

turb<strong>in</strong>e design has been the same for<br />

all units, and the construction itself is<br />

carried out almost simultaneously, <strong>in</strong> a<br />

record time, as requested by the client.<br />

Alejandro Santamaría<br />

Phone +34/91 425 10 19<br />

alejandro.santamaria@vatech-hydro.net<br />

Technical data Talavera:<br />

Output: 1,610 kW<br />

Head: 5.18 m<br />

Speed: 135 rpm<br />

Runner diameter: 2,850 mm<br />

Technical data Palomarejo:<br />

Output: 1,110 kW<br />

Head: 3.58 m<br />

Speed: 110 rpm<br />

Runner diameter: 2,850 mm<br />

sign and coord<strong>in</strong>ation, are possible due<br />

to the close cooperation of Soluziona<br />

Ingeniería, the VA TECH <strong>HYDRO</strong> eng<strong>in</strong>eer<strong>in</strong>g<br />

department <strong>in</strong> Madrid, the<br />

VA TECH <strong>HYDRO</strong> facility <strong>in</strong> Algete, the<br />

generator supplier -Indar- and the<br />

VA TECH <strong>HYDRO</strong> project manager. The<br />

scope of supply <strong>in</strong>cludes an 11 MW<br />

vertical Francis turb<strong>in</strong>e, a synchronous<br />

generator, an ND 1700 butterfly valve, a<br />

penstock of 12 m <strong>in</strong> length, an outlet<br />

tube <strong>in</strong> concrete from the draft tube to<br />

the downstream level with an ND 2000<br />

<strong>in</strong>sulation valve just at the draft tube<br />

outlet, an oil pressure system, a digital<br />

speed governor, a cool<strong>in</strong>g system,<br />

erection, and commission<strong>in</strong>g.<br />

Alfonso Madera<br />

Phone +34/91 425 1038<br />

alfonso.madera@vatech-hydro.net<br />

Technical data:<br />

Output: 11 MW<br />

Head: 81.40 m<br />

Speed: 500 rpm<br />

Runner diameter: 1,280 mm