Installation Procedures<br />

Fuel System<br />

The <strong>Hydronic</strong> M<strong>II</strong> boxed unit is most commonly provided with the<br />

fuel metering pump mounted inside the box. This is to reduce<br />

installation time and to protect the pump from corrosion. If specifications<br />

cannot be met the pump must be mounted externally.<br />

See illustration for connections and specifications. All parts<br />

necessary to do the installation are included in the kit as shown.<br />

Note: Fuel line limits must not be exceeded.<br />

Ensure that the following conditions are met.<br />

Fuel System Tolerances<br />

12<br />

Bottom of the fuel metering pump must be within a height<br />

of 2ʼ6” of the bottom of the fuel pick-up pipe.<br />

Fuel metering pump must be within a total distance of<br />

6ʼ6” from the fuel pick-up pipe.<br />

Pressure runs of less than 1.3 mtrs (50”) use only 3.5mm<br />

rubber (360 75 300)<br />

Control and Safety Devices<br />

Emergency shutdown – EMERGENCY OFF<br />

If an emergency shutdown – EMERGENCY OFF – is necessary<br />

during operation, proceed as follows:<br />

• Switch the heater off with the control<br />

• pull the fuse out<br />

• disconnect the heater from the battery.<br />

Max. 2ʼ6”<br />

FUEL<br />

TANK<br />

Max. 6ʼ6”<br />

2<br />

Max. 6ʼ6”<br />

3<br />

1<br />

2<br />

4<br />

Max. 20”<br />

6<br />

5<br />

Fuel Line<br />

• Route fuel lines from the fuel pick-up pipe to the heater.<br />

• Use <strong>Espar</strong> approved fuel lines.<br />

• Other sizes or types of fuel lines may inhibit proper fuel flow.<br />

• Make proper butt joints using clamps and connector pieces<br />

as shown<br />

• Use a sharp utility knife to cut plastic fuel lines to avoid burrs.<br />

7<br />

Note: Butt joints and clamps on all connections.<br />

6<br />

5<br />

1. Fuel Pick-Up Pipe<br />

2. 11mm Clamp<br />

3. 5.0mm Fuel Line<br />

4. Fuel Metering Pump<br />

5. 9mm Clamp<br />

6. 3.5mm Rubber Connector<br />

7. 2.0mm White Plastic Fuel Line<br />

See notes if length is less than<br />

1.3 mtr (50”)