Introduction<br />
4<br />
Technical data<br />
<strong>Heater</strong> type HYDRONIC M-<strong>II</strong><br />
<strong>Heater</strong> HYDRONIC M8 Biodiesel<br />
Version D 8 W<br />
Heating<br />
medium<br />
Control<br />
of<br />
the<br />
heat<br />
flow<br />
Heat flow (BTU) (Watt)<br />
Figures for operation with diesel fuel. If operated with Biodiesel<br />
the heat flow can reduce by up to 15 %.<br />
Fuel<br />
consumption<br />
( g/<br />
h)<br />
(l/h)<br />
Power<br />
<strong>Water</strong>,<br />
Cooling<br />
fluid<br />
High<br />
Medium<br />
Low<br />
BTU 27297 17061 11943 5118<br />
Watt 8000 5000 3500 1500<br />
g/h<br />
l/h<br />
Electrical power (Watt) in operation 55 46 39 35<br />
Rated<br />
voltage<br />
at<br />
start<br />
– after<br />
25<br />
Sec.<br />
Stand by<br />
Operating range<br />
• Lower voltage limit: An undervoltage protection in<br />
the controller switches the heater off on reaching the<br />
voltage limit.<br />
• Upper voltage limit: An overvoltage protection in the<br />
controller switches the heater off on reaching the<br />
voltage limit.<br />
Tolerable<br />
Flo<br />
w rate<br />
operating<br />
pressure<br />
of<br />
the<br />
Minimum<br />
water<br />
flo<br />
water<br />
pump<br />
at<br />
2 psi<br />
w rate<br />
of<br />
the<br />
Tolerable<br />
operating<br />
temperature<br />
heater<br />
Weight with controller and water pump,<br />
without dosing pump<br />
<strong>Heater</strong> / Control box Diesel<br />
Biodiesel<br />
Dosing pump<br />
Biodiesel<br />
Diesel<br />
Caution:<br />
Failure to comply with the technical data can<br />
result in malfunctions.<br />
0.24<br />
0.90<br />
12<br />
Volt<br />
10<br />
Volt<br />
15<br />
Volt<br />
Operation<br />
0.17<br />
0.65<br />
200<br />
32<br />
0.11<br />
0.40<br />
up to 200 kPa - 30 psi<br />
1400 l/h<br />
500 l/h<br />
370 g/h<br />
132 g/h<br />
Not<br />
approx. 6.2 kg - 13.7 lb<br />
24<br />
Volt<br />
20<br />
Volt<br />
30<br />
Volt<br />
running<br />
0.05<br />
0.18<br />
– 40 °F to +176 °F / –40 °C to +80 °C –40 °F to +185 °F / –40 °C to +85 °C<br />
+17.6 °F to +176 °F / –8 °C to +80 °C –40 °F to +185 °F / –40 °C to +85 °C<br />
– 40 °F to +122 °F / –40 °C to +50 °C –40 °F to +185 °F / –40 °C to +85 °C<br />
+17.6 °F to +122 °F / –8 °C to +50 °C –40 °F to +185 °F / –40 °C to +85 °C