Maintenance, Troubleshooting & Repairs<br />

Repair step 1<br />

Control box / blower unit and jacket<br />

Remove flame sensor<br />

Figure 12<br />

• Unscrew the flame sensor (11) from the housing of the control<br />

box / blower unit.<br />

Dismantle combustion chamber<br />

Figure 13 and 14<br />

• Undo the 3 screws (9) M5 x 16 of the combustion chamber (8).<br />

• Lift the combustion chamber (8) with the fuel pipe until the<br />

grommet (22) is exposed, then remove the combustion cham-<br />

ber.<br />

• Remove combustion chamber seal (23).<br />

Note: Remove combustion chamber seal (23) without leaving<br />

residues. Always check the glow plugs during this repair<br />

step, see repair step 3.<br />

34