Protection and Test Marks –<br />

Electro-technical Symbols<br />

To ensure operating safety of luminaires they<br />

should be protected against humidity and the<br />

entering of solid bodies.<br />

VDE 0710 shows Test and Classification marks,<br />

DIN 40050 applies to Protection Type and IP<br />

numbers.<br />

Application Model Protection Test Mark<br />

VDE 0710<br />

Dry rooms, little dust Protection against solid bodies<br />

over Ø 12 mm —<br />

Humid rooms, exterior or under canopy installations Protection against vertical falling<br />

of drops of water<br />

Public rooms like offices, shops, banks etc. Protection against solid bodies over Ø 1 mm<br />

Humid locations, exterior or under<br />

Protection against solid bodies over Ø 1 mm,<br />

canopy installations, door lighting<br />

splashes of water from all directions<br />

Street lighting.<br />

Protection against solid bodies over Ø 1 mm,<br />

Baths and shower rooms etc.<br />

splashes of water from all directions<br />

Dusty environment,<br />

Protection agains layers of dust an access<br />

hazardous workplaces<br />

to live parts<br />

Humid environment in agricultural building Protection against layers of dust<br />

and splashwater from all directions<br />

Wet and humid locations such as car wash, greenhouses, Protection against layers of dust and jets of water<br />

breweries<br />

from all directions<br />

Some locations as before, which are also subject to extra Protection against dust (absolutely dust tight) and<br />

heavy dust development<br />

against jets of water from all directions<br />

Locations with temporary flooding, Waves, e.g. sea ports, Protection against dust ingress, (completely sealed)<br />

areas with exceptionally high levels of dust<br />

and water jets from all sides<br />

Under water illumination such as<br />

Protection against dust and immersion<br />

fountains, swimming pools<br />

1 m Ws<br />

Special applications under water Protection against prolonged immersion under<br />

water (pressure) > 1 m Ws<br />

Thermal considerations<br />

According to DIN EN 60598, luminaires are<br />

approved for a max. ambient temperature of<br />

Ta = 25° C unless they are marked otherwise.<br />

This technical parameter must be taken into account<br />

when the luminaires featured in this catalogue are<br />

to be used for interior application.<br />

Classification<br />

Protection<br />

VDE 0710<br />

Type<br />

DIN 40050<br />

covered IP20<br />

rainproof IP23<br />

— —<br />

IP40<br />

rainproof IP43<br />

splashwater-proof IP44<br />

dustproof IP50<br />

dust- and splashwater- IP54<br />

proof<br />

dust- and splashwater- IP55<br />

proof<br />

dusttight and jetwaterproof IP65<br />

dust-tight and protected<br />

against powerful water jets<br />

IP66<br />

dusttight and watertight IP67<br />

special arrangement IP68<br />

Protection marks 363<br />