26.10.2013 Views

Exterior Lighting 2012/2013 - Fergin AB

Exterior Lighting 2012/2013 - Fergin AB

Exterior Lighting 2012/2013 - Fergin AB

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Illumination diagrams for simple<br />

planning<br />

The drawings below provide a simple and fast<br />

survey of the average illuminance of a surface at<br />

a specific distance from a light source.<br />

It should be taken into account that the specified<br />

average illuminance value at the named surface<br />

limits represents half the maximum value and does<br />

not drop to "Zero" but decreases<br />

gradually.<br />

If the light approaches at an angle, the average<br />

illuminance value reduced according to the angle<br />

of incidence.<br />

Isolux diagrams<br />

In isolux diagrams the points with the same<br />

illuminance value are joined up with a line<br />

(isolux curve).<br />

0,5 m<br />

1,0 m<br />

1,5 m<br />

6 m<br />

4 m<br />

2 m<br />

5 m<br />

0<br />

5 m<br />

200<br />

100<br />

1,0<br />

2,0<br />

200<br />

100<br />

200<br />

200<br />

8933742<br />

2500 lm<br />

TC-L 18 W<br />

1 m 2 m 3 m 4 m<br />

In the isolux diagrams for sign illumination,<br />

the luminaires are placed above the illuminated<br />

surface.<br />

The distance depends on the luminaire type and the<br />

size of the sign.<br />

4,0<br />

2,0<br />

8,0 16<br />

4,0<br />

32<br />

2,0<br />

64<br />

8,0 16<br />

32<br />

64<br />

32<br />

64<br />

HIT-DE 70 W<br />

5000 lm<br />

8,0<br />

16<br />

8734042<br />

LPH : 4,0 m<br />

2,0<br />

4 m 8 m 12 m 16 m<br />

Wall and pathway luminaires are situated on the<br />

lower side of the diagram. They illuminate the area<br />

below the luminaire from a given height (=LPH).<br />

32<br />

32<br />

16<br />

16<br />

HIT-DE 250 W<br />

20000 lm<br />

8,0<br />

4,0<br />

8275040<br />

2,0<br />

LPH : 10,0 m<br />

5 m 10 m 15 m 20 m 25 m 30 m<br />

In the isolux diagrams for area floodlights, the<br />

luminaires are situated on the left side of the<br />

diagram. The light source height (LPH) and the<br />

dimensions of the area are given as a possible<br />

application example.<br />

Colours<br />

All painted luminaires and their accessories are<br />

chromate pretreated and susequently polyester<br />

powder coated.<br />

Standard textured finishes:<br />

black (RAL 9005)<br />

white (RAL 9002)<br />

silver grey<br />

(Colour sample available upon request)<br />

Further colours also possible.<br />

Planning aids 369<br />

Planning aids

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!