Applications<br />

Two-hand with override, Category 4, EN 954-1<br />

3.0<br />

2006-02<br />

3.0 Applications<br />

Two-hand with examples<br />

override, Category 4, EN 954-1<br />

Features<br />

1 operating mode selector switch<br />

1 E-STOP button<br />

2 two-hand controls<br />

Dual-channel with detection of<br />

shorts across contacts<br />

1 instantaneous load shutdown<br />

Description<br />

A machine can be operated by one or<br />

two people. The machine is enabled<br />

via two-hand buttons.<br />

The machine's motor is switched on if:<br />

The E-STOP button has not been<br />

operated<br />

and<br />

The operating mode selector switch<br />

is in position “0” and both two-hand<br />

buttons are operated or<br />

The operating mode selector switch<br />

is in position “1” and two-hand button<br />

2 is operated.<br />

If one of these conditions is not met,<br />

the signal at output A1.o0 will switch<br />

from high to low and the motor will be<br />

switched off. The status of the operating<br />

mode selector switch is signalled<br />

at outputs A1.o1 and A1.o3.<br />

Feedback loop<br />

The N/C contacts KM1.3 and KM2.3<br />

on contactors KM1.3 and KM2.3 are<br />

connected to the feedback loop input<br />

A1.i11.<br />

Reset<br />

E-STOP monitoring must be activated<br />

through the reset button S6.3 (manual<br />

reset). If the conditions for starting the<br />

motor have been met and the feedback<br />

loop is closed, operation of the<br />

plant is enabled.<br />

Safety assessment<br />

If a switch contact (A1.i0 ... A1.i14)<br />

is overridden, this will be detected<br />

as an error at the next operation.<br />

Safety outputs A1.o0 and A1.o2 will<br />

carry a low signal.<br />

A short circuit between 24 VDC and<br />

inputs A1.i0, A1.i1, A1.i3 ... A1.i10<br />

will be detected as an error. The<br />

safety outputs will carry a low signal.<br />

A short circuit between 24 VDC and<br />

the reset input A1.i12 will be detected.<br />

A short circuit between 24 VDC and<br />

the override input A1.i13 or A1.i14<br />

will be detected.<br />

A short circuit between 24 VDC and<br />

a safety output will be detected and<br />

the safety outputs will carry a low<br />

signal.<br />

It must be possible to protect the<br />

operating mode selector switch<br />

from unauthorised operation.<br />

Configuration, page 1<br />

E-STOP<br />

– Switch type 3 (2 N/C)<br />

– Detection of shorts between<br />

contacts (A1.i0 - test pulse 0,<br />

A1.i1 - test pulse 1)<br />

– Manual reset (A1.i12 - test pulse<br />

3)<br />

Connection point<br />

– Source connection point 1<br />

3.0-16<br />

Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany<br />

Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de<br />

2006-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!