Products<br />

Base units<br />

PNOZ m2p<br />

Preparing for operation<br />

Supply voltage<br />

Supply voltage AC DC<br />

For the safety system<br />

(connector X7)<br />

A1<br />

+ 24 V DC<br />

A2<br />

0 V<br />

For the semiconductor outputs<br />

(connector X2)<br />

Must always be present, even if the semiconductor<br />

outputs are not used<br />

24 V + 24 V DC<br />

0 V 0 V<br />

2.2<br />

Connection examples<br />

Input circuit<br />

Input circuit Single-channel Dual-channel<br />

E-STOP<br />

without detection of shorts across contacts<br />

S1<br />

I0 L+<br />

I0<br />

S1<br />

L+<br />

I1<br />

L+<br />

E-STOP<br />

with detection of shorts across contacts<br />

I0<br />

T0<br />

S1<br />

I0<br />

I1<br />

T1<br />

T0<br />

S1<br />

Reset circuit<br />

Reset circuit<br />

Input circuit without detection of shorts<br />

across contacts<br />

Input circuit with detection of shorts across<br />

contacts<br />

I5<br />

S3<br />

L+<br />

I5<br />

S3<br />

T0<br />

2.2-32<br />

Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany<br />

Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de<br />

NSG-D-2-360-2007-09