Applications<br />

Star-delta start-up, Category B, EN 954-1<br />

2006-02<br />

3.0 Applications<br />

Star-delta start-up, examples<br />

Category B, EN 954-1<br />

Features<br />

1 reset module<br />

2 logic connections<br />

3 semiconductor outputs<br />

1 instantaneous load shutdown<br />

2 load shutdowns with a 5 s delay<br />

Description<br />

When the motor is switched on, after a<br />

5 second delay it is possible to switch<br />

between a star and a delta connection.<br />

A high signal at input A1.i4 selects a<br />

star connection, a high signal at input<br />

A1.i5 selects a delta connection.<br />

Feedback loop<br />

The feedback loop is not used.<br />

Reset<br />

The PNOZ m1p is ready for operation<br />

once supply voltage is applied. If there<br />

is a high signal at input A1.i0, the application<br />

can be activated through a<br />

signal change from low to high at input<br />

A1.i1.<br />

3.0<br />

Configuration<br />

1 reset element<br />

– Non-monitored reset<br />

1 delay element<br />

– 5000 ms<br />

2 AND elements<br />

– 3 inputs<br />

2 negation elements<br />

– 1 input<br />

3 outputs<br />

– Safety output, semiconductor<br />

type<br />

– Single-pole<br />

Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany<br />