FINAL PROJECT: HOSTEL HALMSTAD-SWEDEN - RiuNet
FINAL PROJECT: HOSTEL HALMSTAD-SWEDEN - RiuNet
FINAL PROJECT: HOSTEL HALMSTAD-SWEDEN - RiuNet
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
María Molina Martín<br />
The formula for the energy consumption of the building [(kW·h)/year] is:<br />
Σ (A·U) · coefficient /1000<br />
Having all the U-values and areas calculated, they must be multiplied (A · U):<br />
PARTS OF THE<br />
BUILDING<br />
AREA (m2) U VALUE A · U<br />
FACADES 1491’7752 0’159 237’192<br />
ROOF 983’5 0’152 149’492<br />
GROUND<br />
FLOOR<br />
1056’6864 0’644 680’506<br />
WINDOWS 94’8 1’3 123’24<br />
EXTERIOR<br />
DOORS<br />
11’34 1’3 14’742<br />
Σ(A·U)= 237’192+149’492+680’506+123’24+14’472=1204’902 W/°C<br />
The coefficient depends on the place where the building is situated and the<br />
adequate temperature to be comfortable inside the building.<br />
Heat consumption rates ∆ty<br />
Indoor temperature<br />
18°C 20°C 22°C 24°C<br />
Kiruna<br />
Umea<br />
.<br />
.<br />
.<br />
Goteborg<br />
Malmo<br />
158600<br />
120000<br />
.<br />
.<br />
.<br />
76800<br />
75400<br />
173200<br />
133200<br />
.<br />
.<br />
.<br />
86900<br />
85600<br />
187700<br />
146300<br />
.<br />
.<br />
.<br />
97100<br />
95800<br />
202300<br />
159400<br />
.<br />
.<br />
.<br />
107300<br />
105900<br />
The nearest city to Halmstad, and therefore, the city in which temperatures are<br />
most similar, is Malmo, and a good indoors temperature is 22 ºC, so the<br />
coefficient is 95800.<br />