Operation<br />
WARNING<br />
INJECTION HAZARD<br />
To reduce the risk of serious injury,<br />
whenever you are instructed to relieve<br />
pressure, follow the Pressure Relief<br />
<strong>Pro</strong>cedure on page 9.<br />
How to Use the Pressure Control<br />
The pressure control controls the motor operation so<br />
the sprayer maintains constant fluid pressure at the<br />
pump outlet. Turn the pressure control knob fully<br />
counterclockwise to obtain the minimum setting. Turn<br />
the knob clockwise to increase pressure. See Fig. 4.<br />
The tip guard alerts you to the risk and helps prevent<br />
placing any part of the body close to the spray tip. The<br />
tip guard also adjusts the vertical or horizontal spray<br />
pattern. See page 10. The tip guard holds a reversing<br />
spray tip. The tip is in the spraying position when the<br />
tip handle points forward. See Fig. 5.<br />
Clean the front of the tip frequently during the day’s<br />
operation. First, relieve the pressure.<br />
<br />
<br />
–<br />
+<br />
<br />
<br />
Tip handle shown in<br />
spraying position.<br />
Turn handle 180,<br />
trigger gun to clear clog<br />
Fig. 5<br />
<br />
Fig. 4<br />
02824A<br />
How to Remove a Tip Clog<br />
How to Use the RAC IV Tip Guard<br />
WARNING<br />
To reduce the risk of serious injury from fluid injection:<br />
Never operate the spray gun with the tip guard<br />
removed.<br />
Do not hold your hand, body, or a rag in front of the<br />
spray tip when cleaning or checking a clogged tip.<br />
Always point the gun toward the ground or into a<br />
pail when checking to see if the tip is clear.<br />
Do not try to “blow back” paint; this is not and air<br />
spray sprayer.<br />
1. Release the gun trigger. Lock the safety latch.<br />
Rotate the RAC IV tip handle 180. See Fig. 5.<br />
2. Unlock the safety latch. Trigger the gun into a pail<br />
or onto the ground to remove the clog.<br />
3. Lock the safety latch. Rotate the tip handle to the<br />
spraying position.<br />
4. If the tip is still clogged, lock the safety latch, shut<br />
off and unplug the sprayer, and open the pressure<br />
drain valve to relieve pressure. Clean the spray tip<br />
as shown in manual 307–848, supplied.