Position Position of the flue terminal mm<br />

Horizontal flues<br />

A<br />

directly below an opening, air brick,<br />

opening windows<br />

300<br />

B above an opening, air brick, opening windows 300<br />

C<br />

horizontally to an opening, air brick, opening<br />

windows<br />

300<br />

D below gutter, drain/soil pipe 25<br />

E below eaves 25 (1)<br />

F below a balcony or car port 25<br />

G from vertical drain pipes <strong>and</strong> soil pipes 25<br />

H from internal/external corners 25<br />

H (2) to a boundary alongside the terminal 300<br />

I above adjacent ground or balcony level 300<br />

Position Position of the flue terminal mm<br />

J (2) from surface or a boundary facing the terminal 600<br />

L<br />

from opening (door/window) in car port<br />

into dwelling<br />

1200<br />

M vertical from a terminal 1500<br />

N horizontally from a terminal 300<br />

Vertical flues<br />

P from another terminal 600<br />

Q above roof level 300<br />

R from adjacent opening window 1000<br />

S from adjacent wall to fl ue 300<br />

(1) There should be no ventilation/opening in the eaves within<br />

300mm distance of the terminal.<br />

(2) These dimensions comply with the building regulations,<br />

but they may need to be increased to avoid wall staining <strong>and</strong><br />

nuisance from pluming depending on site conditions.<br />