• Leave these instructions <strong>and</strong> the ‘Benchmark’ Installation,<br />

Commissioning <strong>and</strong> Service Record with the <strong>use</strong>r.<br />

• Re-pressurise the system as instructed by your installer.<br />

• If the symbol is displayed on the screen, display the<br />

fault code memory (see chapter " Trouble-shooting ►Fault<br />

memory").<br />

• Press the reset button<br />

to restart the appliance.<br />

MAINTENANCE<br />

To ensure the continued effi cient <strong>and</strong> safe operation of the<br />

boiler it is recommended that it is checked <strong>and</strong> serviced at<br />

regular intervals. The frequency of servicing will depend upon<br />

the particular installation <strong>and</strong> usage, but in general once a year<br />

should be enough.<br />

It is the Law that any servicing is carried out by a competent<br />

person approved at the time by the Health <strong>and</strong> Safety<br />

Executive.<br />

• Be<strong>for</strong>e commencing with a service or replacement of parts<br />

isolate the boiler from the electrical supply <strong>and</strong> turn off the<br />

gas supply at the gas isolation valve.<br />

• When replacing a part on this appliance, <strong>use</strong> only spare<br />

parts that you can be assured con<strong>for</strong>m to the safety <strong>and</strong><br />

per<strong>for</strong>mance specifi cation that we require. Do not <strong>use</strong><br />

reconditioned or copy parts that have not been clearly<br />

authorised by <strong>Heatline</strong>.<br />

• If any electrical connections have been disconnected <strong>and</strong><br />

after their connection, checks to the earth continuity, polarity,<br />

short circuit <strong>and</strong> resistance to earth must be repeated using a<br />

suitable multimeter, as described in chapter "Trouble-shooting<br />

► Fault diagnosis ► Check the electrical installation".<br />

• After servicing, complete the relevant Service Interval Record<br />

section of the Benchmark Checklist located in the back pages<br />

of this document.<br />

15 Trouble-shooting<br />

• Check the functional fl ow diagram.<br />

15.1.1 Check the electrical installation<br />

2<br />

1<br />

Key<br />

1 Main board<br />

2 Neutral<br />

3 Live<br />

4 Multimeter<br />

• Remove the front casing panel<br />

V<br />

3<br />

4<br />

15.1 Fault diagnosis<br />

The following checks should be per<strong>for</strong>med be<strong>for</strong>e proceeding<br />

onto specifi c diagnostics:<br />

• Make sure that the electricity supply has not been interrupted<br />

<strong>and</strong> that the appliance is connected correctly (See chapter<br />

"Trouble-shooting ► Fault diagnosis ► Check the electrical<br />

installation")<br />

• Check the appliance’s gas supply (See chapter "Troubleshooting<br />

► Fault diagnosis ► Check the gas supply").<br />

• Ensure that the isolating valves are open.<br />

• Check the external electrical supply to the boiler is on <strong>and</strong> a<br />

supply of 230V is present at the ‘L’ <strong>and</strong> ‘N’ terminals on the<br />

main board.<br />

• Check the electrical installation <strong>and</strong> appliance, carry out tests<br />

<strong>for</strong> earth continuity, polarity, short circuit <strong>and</strong> resistance to<br />

earth, using a suitable multimeter.<br />

• Check the link FP –RT is secure or the connected control,<br />

connected at these points, is functioning correctly.<br />

• Bare metal points such as screws or rivets will act as suitable<br />

earth check points on the appliance.<br />

• Ensure that the pressure indicator displays a value of 1.0 bar<br />

(if the pressure falls below 0.4 bar, the air vent function will<br />

run automatically <strong>for</strong> a period of 5 minutes until you see 0.5<br />

bar on the pressure indicator). If not, re-charge the system.<br />

• Check that all external controls are connected correctly.<br />

- <strong>28</strong> - Service Call 0844 736 9042, Technical Help (Chargeable) Call 0906 802 0253