The external wiring must be earthed, with correct polarity <strong>and</strong> in<br />
accordance with current st<strong>and</strong>ards.<br />
The manufacturer declines any responsibility <strong>for</strong> damages to<br />
persons or others ca<strong>use</strong>d by the incorrect installation of the<br />
appliance earthing. This includes failure to comply with current<br />
st<strong>and</strong>ards.<br />
Electrical components have been tested to meet the equivalent<br />
requirements of the BEAB.<br />
• Do not <strong>use</strong> cable greater than 8 mm in diameter <strong>for</strong> the<br />
electrical connections.<br />
All system components must be of an approved type.<br />
• Do not interrupt the mains supply with a time switch or<br />
programmer.<br />
The boiler is suitable <strong>for</strong> installation in bathroom zones 2 <strong>and</strong> 3.<br />
10.2 Access to main board<br />
1<br />
2 3<br />
Key<br />
1 Control box<br />
2 Control box securing screw<br />
3 Mains cable<br />
2<br />
• Keep a distance of a maximum of 30 mm between connector<br />
(1) <strong>and</strong> the start of the insulation (3).<br />
• If using single core wires are <strong>use</strong>d(2) ensure that the are<br />
wrapped together in an insulating sheath.<br />
• Fix the cables in the cable-clamp on the eBox.<br />
10.4 Electrical wiring<br />
Connection of the whole electrical system <strong>and</strong> any heating<br />
system controls to the electrical supply must be through a<br />
common isolator.<br />
Isolation should preferably be by a double pole switched f<strong>use</strong>d<br />
spur box having a minimum contact separation of 3mm on each<br />
pole. The f<strong>use</strong>d spur box should be readily accessible <strong>and</strong><br />
preferably adjacent to the boiler. It should be identifi ed as to its<br />
<strong>use</strong>.<br />
A f<strong>use</strong>d (3A) three pin plug <strong>and</strong> shuttered socket outlet may be<br />
<strong>use</strong>d instead of a f<strong>use</strong>d spur box provided that it is not <strong>use</strong>d in a<br />
room containing a fi xed bath or shower.<br />
• Connect the appliance's power cable to the 230 V singlephase<br />
network + earth.<br />
• Connect the appliance in accordance with the live <strong>and</strong><br />
neutral connections.<br />
230V permanent supply<br />
a<br />
All cables connected to the appliance should<br />
be permanently fixed to the wall. Ensure the<br />
incoming electrical cable is clamped in the clamp<br />
provided.<br />
2<br />
• Remove the control box securing screws (2) <strong>and</strong> pull the<br />
control box (1) <strong>for</strong>ward into the service position.<br />
• Route the mains cable (3) through the grommet <strong>and</strong> connect<br />
to the electrical plug on the controls board.<br />
1<br />
10.3 Main board<br />
1 2 3<br />
3<br />
30mm<br />
max<br />
Key<br />
1 Connector<br />
2 Electrical wires<br />
3 Insulation<br />
When you connect the electrical wires to a connector on the<br />
electronic board:<br />
Key<br />
1 230V permanent supply<br />
2 Main board terminal block: = Mains earth, N = Mains<br />
neutral<br />
L = Mains live<br />
3 F<strong>use</strong><br />
4 Double pole connector<br />
• Connect mains supply as described.<br />
4<br />