Code Service Parameters Unit Description<br />

d.22 DHW dem<strong>and</strong> active (tapping) -<br />

d.23 Central heating mode -<br />

d.33 Speed setpoint of fan rpm<br />

d.44 Digitalized ionisation voltage V<br />

d.68 Unsuccessfull ignitions at fi rst attempt -<br />

d.69 Unsuccessfull ignitions at second attempt -<br />

d.80 Operating hours in heating mode h<br />

d.81 Operating hours in domestic hot water mode h<br />

d.82 Number of burner starts in heating mode -<br />

d.83 Number of burner starts in DHW mode -<br />

d.93 Device Specifi c Number -<br />

d.96 Factory reset -<br />

0 = off<br />

1 = on<br />

0 = CH not available (summer mode)<br />

1 = CH available (winter mode)<br />

Fan speed is displayed between 0 <strong>and</strong> 99.<br />

Multiply the displayed value by 100.<br />

Display the digitalized ionisation voltage. Multiply<br />

the displayed value by 100.<br />

Display the number of unsuccessfull ignitions at fi rst<br />

attempt.<br />

Display the number of unsuccessfull ignitions at<br />

second attempt.<br />

Display the number of operating hours in heating<br />

mode. Multiply the displayed value by 100.<br />

Display the number of operating hours in domestic<br />

hot water mode. Multiply the displayed value by 100.<br />

Display the number of burner starts in heating<br />

mode. Multiply the displayed value by 100.<br />

Display the number of burner starts in DHW mode.<br />

Multiply the displayed value by 100.<br />

Select the product code of the appliance:<br />

<strong>24</strong> = 1<br />

<strong>28</strong> = 2<br />

All parameters stored in EEPROM (main board +<br />

appliance interface) are reset to factory settings if<br />

this function is activated.<br />

0 = deactivated<br />

1 = activated<br />

Factory<br />

setting<br />

Modifiable<br />

parameter<br />

- no<br />

- no<br />

- no<br />

- no<br />

- no<br />

- no<br />

- no<br />

- no<br />

- no<br />

- no<br />

15<br />

22<br />

yes<br />

0 yes<br />

13.1.1 Status of the appliance<br />

• Press button <strong>for</strong> 7 seconds to learn the current state of<br />

functioning of the appliance.<br />

The screen displays "S" <strong>and</strong> the state of the appliance.<br />

• To exit to display menu, press the button <strong>for</strong> 3<br />

seconds.<br />

Status Heating Mode<br />

S.00 No request <strong>for</strong> heating<br />

S.01 Pre-run fan<br />

S.02 Pre-run pump<br />

S.03 Ignition<br />

S.04 Burner lit<br />

S.05 Post run pump/fan<br />

S.06 Post run fan<br />

S.07 Post run pump<br />

S.08 Time delay anti short-cycles after heating<br />

Status Domestic hot water mode<br />

S.10 Request <strong>for</strong> domestic hot water<br />

S.11 Pre-run fan<br />

S.13 Ignition<br />

S.14 Burner lit<br />

S.15 Post run pump/fan<br />

S.16 Post run fan<br />

S.17 Post run pump<br />

Status Domestic hot water heating<br />

S.20 Pre-run pump<br />

S.21 Pre-run fan<br />

S.23 Ignition<br />

S.<strong>24</strong> Burner lit<br />

S.25 Post run pump/fan<br />

S.26 Post run fan<br />

S.27 Post run pump<br />

S.<strong>28</strong> The boiler blocks tank reheating after a reheating cycle.<br />

Status Specific messages<br />

S.30 No request <strong>for</strong> heating or domestic water.<br />

S.31 "Hot water only" mode<br />

S.32 Tolerance indication time of fan speed.<br />

S.34 "Frost protection" mode<br />

S.35 The speed of fan in functioning phase is outside tolerance<br />

S.36 Heating Blockage<br />

S.37<br />

The speed of fan in functioning phase is outside tolerance<br />

during operation<br />

S.41 High pressure value<br />

S.53<br />

Waiting cycle: temperature differential between heating fl ow<br />

<strong>and</strong> return is too high. If ∆T > 30, <strong>for</strong>cing to Pmin<br />

S.54<br />

Waiting cycle: lack of water in the installation/temperature<br />

rise between heating fl ow <strong>and</strong> return is too high<br />

S.58 A fi xed modulation until the condition provides<br />

S.90 End of fi nal control test<br />

S.92 Water fl ow sensor control, DHW <strong>and</strong> CH is in blockage<br />

S.95 Voltage control, DHW <strong>and</strong> CH is in blockage<br />

S.96 Return sensor control, DHW <strong>and</strong> CH is in blockage<br />

S.97 Water pressure sensor control, DHW <strong>and</strong> CH is in blockage<br />

S.98 Flow/Return sensor control, DHW <strong>and</strong> CH is in blockage<br />