2.2 Data label<br />
The data label certifi es the country where the appliance is<br />
intended to be installed. It is located on the rear of the drop<br />
down control box<br />
The data label contains the following data:<br />
- The name of the manufacturer<br />
- The country of intended destination<br />
- The commercial name of the appliance <strong>and</strong> its serial number<br />
- The types of fl ue installations authorised<br />
- The appliance's gas category<br />
Product/production certifi ed by:<br />
Notifi ed body IMQ 52BP2727 CE Directives 2009/142/EEC.<br />
52BP27<strong>28</strong>DR CE Directives 92/42/EEC.<br />
The CE mark indicates that the appliances described in this<br />
manual are in compliance with the following directives:<br />
- European directive n°2009-142 relative to gas appliances<br />
- European directive n°2004-108 from the European Parliament<br />
<strong>and</strong> Council relative to electromagnetic compatibility<br />
- European directive n°2006-95 from the European Parliament<br />
<strong>and</strong> Council relative to low voltage<br />
- European directive n°92-42 relative to the yield of boilers<br />
- The gas type, group <strong>and</strong> pressure, set in the factory<br />
- The DHW specifi c fl ow rate (D)<br />
- The maximum pressure in the heating circuit (PMS)<br />
- The maximum pressure in the domestic water circuit (PMW)<br />
- The NOx class of the appliance<br />
- The type <strong>and</strong> voltage of electricity supply<br />
- The maximum power rating<br />
- The electrical protection class<br />
- The minimum <strong>and</strong> maximum heat input (Q)<br />
- The minimum <strong>and</strong> maximum power output (P)<br />
- The CE number <strong>and</strong> logo<br />
a<br />
The appliance shall only be connected to the gas<br />
type(s) indicated on the data label.<br />
2.3 Gas category<br />
This boiler is <strong>for</strong> <strong>use</strong> only on G20, but can be converted <strong>for</strong> <strong>use</strong><br />
on G31.<br />
• To adapt the appliance to another type of gas, see the<br />
chapter "Gas conversion".<br />
2.4 Regulation <strong>and</strong> statutory requirements<br />
CE Mark<br />
This boiler meets the requirements of Statutory Instrument,<br />
No. 3083 The Boiler (Effi ciency) Regulations, <strong>and</strong> there<strong>for</strong>e is<br />
deemed to meet the requirements of Directive 92/42/EEC on the<br />
effi ciency requirements <strong>for</strong> new hot water boilers fi red with liquid<br />
or gaseous fuels.<br />
Type test <strong>for</strong> purposes of Regulation 5 certifi ed by:<br />
Notifi ed body IMQ 52BP2727 CE Directives 2009/142/EEC.<br />
52BP27<strong>28</strong>DR CE Directives 92/42/EEC.<br />
2.5 Hydraulic schematic<br />
13<br />
12<br />
11<br />
10<br />
9<br />
8<br />
7<br />
23<br />
6<br />
5<br />
3<br />
2<br />
1<br />
Key<br />
1 Gas service isolating valve (Yellow)<br />
2 Heating flow isolating valve (Red)<br />
3 Heating safety valve<br />
4 N/A<br />
5 DHW flow sensor<br />
6 Domestic plate to plate heat exchanger<br />
7 By-pass<br />
8 Heating return thermistor (Blue)<br />
9 Condensate trap<br />
10 Ignition <strong>and</strong> control electrode<br />
11 Burner<br />
12 Main heat exchanger<br />
13 Thermal f<strong>use</strong><br />
14 Flue outlet<br />
15 Silencer<br />
16 Heating expansion vessel<br />
17 Fan<br />
18 Gas control valve<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
20<br />
21<br />
22<br />
<strong>24</strong><br />
25<br />
26<br />
27<br />
- 4 - Service Call 0844 736 9042, Technical Help (Chargeable) Call 0906 802 0253