Parameters<br />

1.054 Ramp section Unit: integer<br />

Relationship to<br />

parameter:<br />

1,050 to 1,053<br />

Parameter manual:<br />

p. xy<br />

Selection of used ramp pair<br />

Transfer status:<br />

42 Operating manual <strong>FKO</strong><br />

2<br />

min: 0 own value (to<br />

be entered!)<br />

max.: 6<br />

def.: 0<br />

0 = deceleration 1 (1.050) / acceleration 1 (1.051)<br />

1 = deceleration 2 (1.052) / acceleration 2 (1.053)<br />

2 = digital input 1 (false = ramp pair 1 / True = ramp pair 2)<br />

3 = digital input 2 (false = ramp pair 1 / true = ramp pair 2)<br />

4 = digital input 3 (false = ramp pair 1 / true = ramp pair 2)<br />

5 = digital input 4 (false = ramp pair 1 / true = ramp pair 2)<br />

6 = <strong>FKO</strong> Soft-PLC<br />

1.100 Control mode Unit: integer<br />

Relationship to<br />

parameter:<br />

1,130<br />

1,131<br />

2,051 to 2,057<br />

3,050 to 3,071<br />

Parameter manual:<br />

p. xy<br />

Selecting the operating mode.<br />

Transfer status:<br />

2<br />

min: 0 own value (to<br />

be entered!)<br />

max.: 4<br />

def.: 0<br />

After SW release (1,131) and hardware release, the drive control runs as<br />

follows:<br />

0 = frequency control mode, with the target value of the selected reference<br />

channel (1,130)<br />

1 = PID process control, with the target value of the PID process control<br />

(3,050–3,071)<br />

2 = preset speed mode, with the frequencies specified by parameters<br />

2,051–2,057<br />

3 = selection from <strong>FKO</strong> Soft-PLC