KNOW-HOW 100 V PA TECHNOLOGY<br />

The wiring is in general very simple. All loudspeakers with<br />

built-in transformers can be parallel connected as in the following<br />

drawing.<br />

Please note: The sum of all power settings at the loudspeaker-transformers<br />

should not exceed the amplifier´s<br />

nominal rating considerably.<br />

We recommend to choose the amplifier´s<br />

nominal rating slightly higher than it may seem<br />

necessary at the first system layout.<br />

Connecting the speakers this way allows many versions,<br />

which will be presented in detail in the later following part<br />

“Tips and clues for 100V PA technology”. Here are only<br />

some of them:<br />

– Interconnecting of loudspeakers of different ratings without<br />

any difficulties.<br />

– If one or more loudspeaker fails, the remaining speakers,<br />

i.e. the whole system still works.<br />

– Each loudspeaker takes only so much power from the<br />

100V line as is set at the transformer. It is easily possible<br />

to connect 40 speakers, each with a load rating of 3W, to<br />

one 120W amplifier, which may already be sufficient for<br />

the acoustic irradiation of a small supermarket.<br />

– You can install single, group or all-call.<br />

– You can set priority circuits, emergency calls and special<br />

announcements, as well as switch on central fire alarm<br />

systems.<br />

SAFETY TIPS<br />

● The installation of 100V PA systems should be performed<br />

by experts who are familiar with the relevant safety regulations.<br />

● Only materials and tools approved for 100V should be<br />

used for the system.<br />

● Please pay absolute attention to the required protection<br />

against contact, even if the equipment used is secured to<br />

a large extent by CE-conformity.<br />

● If amplifiers are fully loaded, high voltages occur that can<br />

endanger your physical health in case of contact. You<br />

should therefore always switch off loudspeakers or<br />

amplifiers before opening and working on them.<br />

*<br />

Electromagnetic compatibility and low-voltage guidelines<br />

RCS tests all devices and products, which are subject of the CE guidelines by certified test<br />

laboratories. By the fact it is guaranteed that you may sell our devices in Germany and in the<br />

European Union domestic market without additional checks.<br />

© Copyright by RCS. Reproduction and duplication, also in part, only with our express permission.<br />

291

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!