8.4 Rectifier Unit (NBA-797A)<br />

(1) Dimensions<br />

・Width<br />

270mm<br />

・Height<br />

430mm<br />

・Depth<br />

175mm<br />

(2) Mounting Wall type, drip proof structure<br />

(3) Mass Approx. 18kg<br />

(4) Input power AC 100/110/115/200/220/230V±15%<br />

50/60Hz, Single phase<br />

(5) Power consumption 200VA<br />

(6) Output DC 26V, 7A<br />

8.5 Unit-to-unit Spacing<br />

Maximum Cable Length Standard Cable Length<br />

Scanner to display 20m 15m<br />

Display to rectifier (Note) 2m<br />

(Note)<br />

About power cable length between display to rectifier, see "9.5.3 Selecting<br />

a Long Cable"<br />

Attention<br />

• Install each equipment so that the length of the cable between a snanner unit and a<br />

display unit does not exceed 20m. If the regular length is exceeded, it may become<br />

the cause of causing poor adjustment and the defect of a system of operation.<br />

・The standard cables are provided with connectors and plugs.<br />