Before magnified<br />

After magnified<br />

2. Changing the transmission pulse width<br />

With respect to ranges of 1.5 NM, 3 NM and 6 NM, the transmission pulse width may<br />

be changed.<br />

If a wider pulse width is selected, the echo images on the PPI screen will be extended in<br />

the range direction. Conversely, when a narrower pulse width is selected, the image is<br />

compressed (made shorter) in the range direction.<br />

The difference of this function from the image expansion function is that when the<br />

pulse width becomes wider, echoes that had not been visible are sometimes visible as<br />

images.<br />

Attention<br />

• When switching to a wide pulse width, two targets that are in proximity in the range<br />

direction (depth) may be shown as one echo on the PPI screen.<br />

(a) Select "1.5NM", "3NM", or "6NM" in the line "TX PULSE" - the menu<br />

"RADAR SET-UP 1".<br />