12.03.2014 Views

TM-6710/6710CL High-Speed Progressive Scanning ... - JAI Pulnix

TM-6710/6710CL High-Speed Progressive Scanning ... - JAI Pulnix

TM-6710/6710CL High-Speed Progressive Scanning ... - JAI Pulnix

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Page 19<br />

Operation<br />

This selects a mode for external shutter speed control. Hexadecimal shutter number (3 digit) follows<br />

“SX” command (e.g., “080” = 128H, shutter speed = 4.1msec). It moves the shutter discharge pulse<br />

at every 1H (32 µsec.) period from 254 (no shutter) to 1H (max. speed).<br />

Command G<br />

Function: A/D pre-amp gain control.<br />

The “GM” command controls the gains of the A channel and the B channel. The “GA” and “GB”<br />

commands fine tune the gain of the A and B channels respectively, to achieve balance. The ratio is<br />

about 5:1.<br />

Examples:<br />

A (5:1)<br />

R4<br />

R3<br />

R1<br />

Ch. A<br />

“:”, “GM”, “D2”, CR<br />

D2 = gain 210<br />

3AH, 47H, 46H, 46H, 0DH<br />

M<br />

B (5:1)<br />

R5<br />

R6<br />

R2<br />

Ch. B<br />

“:”, “GA”, “12”, CR<br />

3AH, 47H, 31H, 32H, 0DH<br />

Gain control value 18<br />

GAIN (dB)<br />

Voltage<br />

3.5 4<br />

30<br />

3.1 3<br />

2.5 2<br />

20<br />

1.9 1<br />

10<br />

0<br />

90 130 160 190 225<br />

Counts<br />

1.0 2.0 3.0 4.0<br />

VOLTAGE (V)<br />

Command V<br />

Function: A/D reference voltage control. In the default gain setting there is no shutter. The A/D<br />

reference voltage bottom is preset to 0.45V. The controllable range of the reference voltage (Vref1,<br />