Operation<br />
This selects a mode for external shutter speed control. Hexadecimal shutter number (3 digit) follows<br />
“SX” command (e.g., “080” = 128H, shutter speed = 4.1msec). It moves the shutter discharge pulse<br />
at every 1H (32 µsec.) period from 254 (no shutter) to 1H (max. speed).<br />
Command G<br />
Function: A/D pre-amp gain control.<br />
The “GM” command controls the gains of the A channel and the B channel. The “GA” and “GB”<br />
commands fine tune the gain of the A and B channels respectively, to achieve balance. The ratio is<br />
about 5:1.<br />
Examples:<br />
A (5:1)<br />
R4<br />
R3<br />
R1<br />
Ch. A<br />
“:”, “GM”, “D2”, CR<br />
D2 = gain 210<br />
3AH, 47H, 46H, 46H, 0DH<br />
M<br />
B (5:1)<br />
R5<br />
R6<br />
R2<br />
Ch. B<br />
“:”, “GA”, “12”, CR<br />
3AH, 47H, 31H, 32H, 0DH<br />
Gain control value 18<br />
GAIN (dB)<br />
Voltage<br />
3.5 4<br />
30<br />
3.1 3<br />
2.5 2<br />
20<br />
1.9 1<br />
10<br />
0<br />
90 130 160 190 225<br />
Counts<br />
1.0 2.0 3.0 4.0<br />
VOLTAGE (V)<br />
Command V<br />
Function: A/D reference voltage control. In the default gain setting there is no shutter. The A/D<br />
reference voltage bottom is preset to 0.45V. The controllable range of the reference voltage (Vref1,<br />
<strong>TM</strong>-<strong>6710</strong>/<strong>6710</strong>CL <strong>High</strong>-<strong>Speed</strong> <strong>Progressive</strong> <strong>Scanning</strong> CCD Camera