Operation<br />

Vref2) is between 1V and 0.2V. The controllable range of the reference top voltage (Vtop) is between<br />

1.5V and 3V.<br />

V<br />

Vtop Voltage<br />

3<br />

4<br />

2<br />

A/D Input<br />

Vtop 2.15V<br />

3<br />

2<br />

1<br />

1K (10-bit)<br />

256 (8-bit)<br />

1<br />

0<br />

Vbtm 0.45V<br />

0<br />

255<br />

Counts<br />

Figure 1 Figure 2<br />

Examples:<br />

Command W<br />

“:”, “VT”, “7E”, CR<br />

7EH = Vref top: 126<br />

3AH, 56H, 37H, 45H, 36H, 0DH<br />

Vref (V)<br />

1.2<br />

1<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

Function: Write data to the selected pages or calibration<br />

data table.<br />

0<br />

Figure 3<br />

255<br />

Counts<br />

Saving to page (from 0 through 6):<br />

“:”, “W”, “P” - “6”, CR<br />

3AH, 57H, 41H - 36H, 0DH<br />

(Page 0 is factory use only)<br />

Saving the current gain setting to User Table (A) with the “WU” command:<br />

Command L<br />

“:”, “W”, “U”, “A”, CR<br />

3AH, 57H, 55H, 41H, 0DH<br />

Function: Select and read a memory page and set the preprogrammed data. This loads the data from the<br />

preset page location or preset gain table.<br />

Command R<br />

“:”, “L”, “P” - “6”, CR<br />

3AH, 4CH, 50H - 36H, 0DH<br />

Function: Output data values of camera memory (PULNiX software is available).<br />