Select mode:<br />

This installation selects between two kinds of handling the time of an down-counting timer. It<br />

influences the time addresses only, not the data of the LTC(MTD).<br />

6 6-digits operating mode: the time addresses of the LTC output will be prepared for a<br />

LTC reader display, which only displays hours/minutes/seconds. It is supposed, that<br />

the LTC reader adds one frame to compensate for delay as it is a recommended<br />

practice. In a 6-digits display the down-counting timer reaches zero as soon as the<br />

seconds switches from 1 to 0. Compared with the 8-digits operating mode the time<br />

addresses get a one second minus one frame addition.<br />

Down-counting<br />

hours:minutes:seconds(:frames<br />

)<br />

Time addresses,<br />

6-digit mode<br />

LTC display,<br />

8 digits<br />

LTC display,<br />

6 digits<br />

00:00:02 (:01) 00:00:02:00 00:00:02:01 00:00:02<br />

00:00:02 (:00) 00:00:01:24 00:00:02:00 00:00:02<br />

00:00:01 (:24) 00:00:01:23 00:00:01:24 00:00:01<br />

etc.<br />

00:00:01 (:01) 00:00:01:00 00:00:01:01 00:00:01<br />

00:00:01 (:00) 00:00:00:24 00:00:01:00 00:00:01<br />

00:00:00 (end) 00:00:00:23 00:00:00:24 00:00:00<br />

8 8-digits operating mode: the time addresses of the LTC output will be prepared for a<br />

LTC reader display, which displays the frames as well. It is supposed, that the LTC<br />

reader adds one frame to compensate for delay as it is a recommended practice. In a<br />

8-digits display the down-counting timer reaches zero if even the frames have 00. If<br />

the 8-digits mode is selected but a 6-digits display used, the time at the display<br />

appears to be one second in advance.<br />

Down-counting<br />

hours:minutes:seconds(:frames<br />

)<br />

Time<br />

addresses,<br />

8-digit mode<br />

LTC display<br />

8 digits<br />

LTC display<br />

6 digits<br />

00:00:02 (:01) 00:00:01:01 00:00:01:02 00:00:01<br />

00:00:02 (:00) 00:00:01:00 00:00:01:01 00:00:01<br />

00:00:01 (:24) 00:00:00:24 00:00:01:00 00:00:01<br />

00:00:01 (:23) 00:00:00:23 00:00:00:24 00:00:00<br />

etc.<br />

00:00:01 (:01) 00:00:00:01 00:00:00:02 00:00:00<br />

00:00:01 (:00) 00:00:00:00 00:00:00:01 00:00:00<br />

00:00:00 (end) 23:59:59:24 00:00:00:00 00:00:00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!