5 Connection of position and speed sensors<br />

5.1 General notes<br />

Depending on module type the <strong>SMX</strong> module (<strong>SMX</strong>11/<strong>SMX</strong>12) has (1/2) external encoder<br />

interfaces <strong>for</strong> the connection of industrial incremental and absolute encoders. The encoder<br />

interfaces can be configured as incremental, SIN/COS, or as absolute SSI-encoders.<br />

It is also possible to connect 2 incremental signal generating sensors (e.g. proximity<br />

switches) to the counting inputs of the <strong>SMX</strong> module. The signals must each be read in with<br />

normal and complementary track.<br />

IMPORTANT<br />

The voltage supply of the encoder system uses the dedicated terminal on the <strong>SMX</strong> module.<br />

This voltage is applied to the encoder plug and monitored by an internal diagnostic process.<br />

When the sensor is supplied with an external voltage, this voltage must be supplied through<br />

the encoder plug. The corresponding terminal (encoder supply voltage) on the <strong>SMX</strong> module<br />

remains unoccupied.<br />

If an external sensor voltage supply is not recirculated through the encoder plug, any failure<br />

of this supply must be included in the fault examination of the overall system. This, in<br />

particular, requires evidence that this fault is detected or can be excluded when the specified<br />

operating voltage of the overall system is fallen short of / exceeded.<br />

EMC - measures such as shielding etc. must be observed.<br />

The two encoders must be non-interacting to each other. This applies <strong>for</strong> both the electrical<br />

as well as the mechanical part.<br />

If both encoders are coupled to the facility to be monitored via common mechanical parts, the<br />

connection must be positively designed and should not have any parts that are susceptible to<br />

wear (chains, toothed belts, etc.). Should this be the case, additional monitoring features <strong>for</strong><br />

the mechanical connection of the sensors (e.g. monitoring of a toothed belt) are required).<br />

In case of an active position processing at least one absolute value encoder must be used.<br />

When using two equivalent sensors one must make sure that the sensor with the higher<br />

resolution is configured as sensor 1 (process sensor) and the sensor with the lower<br />

resolution as sensor 2 (reference sensor).<br />