<strong>Installation</strong> <strong>Manual</strong><br />

6.3 Connection of an incremental encoder<br />

Pin 1<br />

n.c.<br />

Pin 2<br />

Ground<br />

Pin 3<br />

n.c.<br />

Pin 4<br />

B-<br />

Sub-D plug<br />

(9 pin) <strong>SMX</strong><br />

Pin 5<br />

A+<br />

Incremental<br />

encoder<br />

Pin 6<br />

A-<br />

Pin 7<br />

n.c.<br />

Pin 8<br />

B+<br />

Pin 9<br />

Supply voltage<br />

Pins 1, 3 and 7 stay open and are reserved <strong>for</strong> later expansions.<br />

HB-37350-810-01-10E-EN <strong>SMX</strong> installation manual.doc Page 30 of 30