Chapter 2<br />

About the MSR57P <strong>Speed</strong> Monitoring <strong>Safe</strong>ty Relay<br />

Hardware Features<br />

The MSR57P relay features five dual-channel inputs, three sets of<br />

sourcing safety outputs, and one bipolar safety output. You can<br />

configure dual-channel inputs to accept contact devices with two<br />

normally closed contacts, or one normally closed and one normally<br />

open contact. They can also be configured for single channel<br />

operation.<br />

IMPORTANT<br />

Single-channel operation does not meet SIL CL3, PL(e), Cat 4<br />

safety integrity.<br />

These inputs also support output signal switching devices (OSSD).<br />

Each output has integral pulse-test checking circuitry. Two RJ-45<br />

connectors support encoder inputs. The MSR57P relay features status<br />

indicators and status data for troubleshooting.<br />

26 Publication 440R-UM004A-EN-P - December 2008