5.5 CREMATORIA IN THAILAND, BY UTE KARL (BANGKOK CONSULTATION)<br />

Slide 1<br />

Slide 4<br />

Crematoria in Thailand<br />

Technical Review of the Crematories<br />

à Basic Cremati<strong>on</strong> Data for<br />

Bangkok<br />

à Technical Review of the<br />

Crematories<br />

à Analysis of Status Quo<br />

in Bangkok<br />

All cremators visited during site inspecti<strong>on</strong> are<br />

designed as flat bed systems, mostly equipped<br />

with a fixed hearth.<br />

à Opti<strong>on</strong>s for Rehabilitati<strong>on</strong><br />

Measures<br />

GTZ Study May 2003 – March 2004<br />

Slide 2<br />

Slide 5<br />

Basic Cremati<strong>on</strong> Data for Bangkok<br />

Analysis of Status Quo in Bangkok<br />

309 temples in Bangkok; most of theseused for less than five<br />

cremati<strong>on</strong>sper m<strong>on</strong>th<br />

The technical standard of the temples can be summarised as follows:<br />

- mostly n<strong>on</strong>-automatic coffin feeding into the cremati<strong>on</strong> chamber,<br />

- cremator type, mostly based <strong>on</strong> flatbed-fixed hearth systems,<br />

- cremator design is mostly very simple, limited for 1 to 2 cremati<strong>on</strong>s/day,<br />

- mostly primary and sec<strong>on</strong>dary combusti<strong>on</strong> chambers,<br />

- burner systems using oil or gas,<br />

- no integrated process c<strong>on</strong>trol system,<br />

- no flue gas c<strong>on</strong>diti<strong>on</strong>ing and cleaning devices, except of <strong>on</strong>e crematorium<br />

equipped with a cycl<strong>on</strong>e.<br />

In-effective use of existing crematoriain Bangkok<br />

Technical measures reducing PCDD, PCDF and other harmful<br />

substances are not implemented.<br />

Source: GTZ 2004<br />

Slide 3<br />

Slide 6<br />

Basic Cremati<strong>on</strong> Data for Bangkok<br />

Opti<strong>on</strong>s for Rehabilitati<strong>on</strong> Measures<br />

During site inspecti<strong>on</strong> in totally 20 cremati<strong>on</strong> temples were visited<br />

and their characteristic data were collected.<br />

Collected plant informati<strong>on</strong>:<br />

• Technical informati<strong>on</strong>, suchas cremator design (primary and<br />

sec<strong>on</strong>dary chamber), burner equipment, combusti<strong>on</strong> air device,<br />

flue gastreatment<br />

• Available operati<strong>on</strong> andemissi<strong>on</strong>data, such as temperatures,<br />

opacity and emissi<strong>on</strong> data available by BMA/PCD,<br />

• Statusof operati<strong>on</strong>, such as coffin feeding, cremati<strong>on</strong> processing,<br />

preheating,durati<strong>on</strong> of cremati<strong>on</strong>, religiousaspects, etc,<br />

• Technical Maintenance, such as procedure andresp<strong>on</strong>sibility,<br />

• Basis for rehabilitati<strong>on</strong>measures.<br />

No rehabilitati<strong>on</strong> / Close down:<br />

- coal fired cremators,<br />

- cremators, not equipped with a post combusti<strong>on</strong> chamber,<br />

- cremators, characterised by extremely unsatisfying combusti<strong>on</strong> c<strong>on</strong>diti<strong>on</strong>s<br />

as given by cremati<strong>on</strong> cycle of more than 180 min and energy<br />

c<strong>on</strong>sumpti<strong>on</strong> rates of more than 1,100 kWh/cremati<strong>on</strong>.<br />

Rehabilitati<strong>on</strong> measures shall achieve:<br />

- reducti<strong>on</strong> of envir<strong>on</strong>mental impact by minimising combusti<strong>on</strong>-dependent<br />

pollutants, such as CO and total hydrocarb<strong>on</strong>s as well as partly NOx,<br />

- reducti<strong>on</strong> of fuel c<strong>on</strong>sumpti<strong>on</strong>,<br />

- improvement of operati<strong>on</strong>al c<strong>on</strong>diti<strong>on</strong>s,<br />

- increase of cremati<strong>on</strong> capacity, in order to compensate the lack of<br />

cremati<strong>on</strong>s, resulting from the proposed close-down of the above<br />

described crematoria with extremely unsatisfying technical standard.<br />