Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Solenoid</strong>-<strong>Diaphragm</strong> <strong>Dosing</strong> <strong>Pump</strong> MAGDOS LP<br />
Operating Instructions<br />
5 Technical Data<br />
5.1 Delivery capacity data<br />
Please note that some of this data only represents guide values. The actual capacity of a dosing pump depends on various factors. For approximate<br />
values of the delivery capacity at diffferent pressures, refer to „Delivery characteristic curves“ (see page 53).<br />
Information<br />
Value<br />
MAGDOS LP size<br />
05 1 2 4 6 10 15<br />
Delivery capacity at max. backpressure<br />
l/h 0.36 0.76 1.9 3.4 6.2 9.0 13<br />
ml/stroke 0.05 0.05 0.2 0.31 0.57 0.83 0.86<br />
max. back pressure bar 16 8 6 3<br />
Max. delivery pressure in Eco-Mode 1* bar 10 6 4 2<br />
Max. delivery pressure in Eco-Mode 2* bar 6 4 2 1<br />
Delivery capacity at average backpressure<br />
l/h 0.54 1.1 2.3 3.8 6.8 10 15<br />
ml/stroke 0.08 0.07 0.24 0.35 0.63 0.92 1.0<br />
Average back pressure bar 8 4 3 1<br />
Max. stroke frequency RPM 120 250 160 180 250<br />
Suction head for non-gassing media<br />
(suction line filled)<br />
mWS 5 3 2<br />
Table 5-1: Output data<br />
* In the case of operation in Eco-Mode energy saving mode, the delivery capacity is 5-10 % less than in normal mode (with the same backpressure).<br />
If necessary, recalibration may be necessary (see „Calibrating the dosing pump“ on page 38).<br />
5.2 Operating conditions and limits<br />
Information<br />
Value<br />
MAGDOS LP size<br />
05 – 15<br />
Max. ambient temperature °C 45 (40 with PVC parts)<br />
Relative humidity % Max. 90<br />
Max. sound pressure level (depressurised) dB(A) 68 – 75<br />
Max. sound pressure level (at test pressure)<br />
dB(A) 65 – 70<br />
Max. supply pressure mbar 800<br />
Viscosity limits mPa s 300* / 1000**<br />
Linear dosing range % 10 – 100<br />
Table 5-2: Operating conditions and limits<br />
* With a viscosity of ~300 mPa s and above, you must use spring-loaded valves.<br />
** If the viscosity is above 1000 mPa s, this must be checked individually and the stroke frequency must be between 50 and 100 strokes/min.<br />
© Lutz-Jesco GmbH 2012<br />
Subject to technical changes.<br />
BA-10231-02-V01<br />
Technical Data<br />
Delivery capacity data<br />
11