05.08.2014 Views

Solenoid-Diaphragm Dosing Pump

Solenoid-Diaphragm Dosing Pump

Solenoid-Diaphragm Dosing Pump

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Solenoid</strong>-<strong>Diaphragm</strong> <strong>Dosing</strong> <strong>Pump</strong> MAGDOS LP<br />

Operating Instructions<br />

5 Technical Data<br />

5.1 Delivery capacity data<br />

Please note that some of this data only represents guide values. The actual capacity of a dosing pump depends on various factors. For approximate<br />

values of the delivery capacity at diffferent pressures, refer to „Delivery characteristic curves“ (see page 53).<br />

Information<br />

Value<br />

MAGDOS LP size<br />

05 1 2 4 6 10 15<br />

Delivery capacity at max. backpressure<br />

l/h 0.36 0.76 1.9 3.4 6.2 9.0 13<br />

ml/stroke 0.05 0.05 0.2 0.31 0.57 0.83 0.86<br />

max. back pressure bar 16 8 6 3<br />

Max. delivery pressure in Eco-Mode 1* bar 10 6 4 2<br />

Max. delivery pressure in Eco-Mode 2* bar 6 4 2 1<br />

Delivery capacity at average backpressure<br />

l/h 0.54 1.1 2.3 3.8 6.8 10 15<br />

ml/stroke 0.08 0.07 0.24 0.35 0.63 0.92 1.0<br />

Average back pressure bar 8 4 3 1<br />

Max. stroke frequency RPM 120 250 160 180 250<br />

Suction head for non-gassing media<br />

(suction line filled)<br />

mWS 5 3 2<br />

Table 5-1: Output data<br />

* In the case of operation in Eco-Mode energy saving mode, the delivery capacity is 5-10 % less than in normal mode (with the same backpressure).<br />

If necessary, recalibration may be necessary (see „Calibrating the dosing pump“ on page 38).<br />

5.2 Operating conditions and limits<br />

Information<br />

Value<br />

MAGDOS LP size<br />

05 – 15<br />

Max. ambient temperature °C 45 (40 with PVC parts)<br />

Relative humidity % Max. 90<br />

Max. sound pressure level (depressurised) dB(A) 68 – 75<br />

Max. sound pressure level (at test pressure)<br />

dB(A) 65 – 70<br />

Max. supply pressure mbar 800<br />

Viscosity limits mPa s 300* / 1000**<br />

Linear dosing range % 10 – 100<br />

Table 5-2: Operating conditions and limits<br />

* With a viscosity of ~300 mPa s and above, you must use spring-loaded valves.<br />

** If the viscosity is above 1000 mPa s, this must be checked individually and the stroke frequency must be between 50 and 100 strokes/min.<br />

© Lutz-Jesco GmbH 2012<br />

Subject to technical changes.<br />

BA-10231-02-V01<br />

Technical Data<br />

Delivery capacity data<br />