Y-SERIES OVERVIEW<br />

CITY MULTI ® Y-Series:<br />

The two-pipe zoned<br />

system designed for<br />

heat pump operation<br />

Y-Series outdoor units are flexible enough<br />

to cool or heat up to 50 individual zones,<br />

maximizing building design options.<br />

They feature low operating sound, easy<br />

piping and maintenance design, and light<br />

weight. Y-Series units are available in<br />

both 208/230V and 460V up to 30 tons<br />

for different applications, (6-20 ton units<br />

meet ENERGY STAR ® Light Commercial<br />

Requirements and will exceed proposed<br />

ASHRAE 90.1 efficiency ratings for 2010).<br />

Design flexibility<br />

Flexibility is the key with the CITY MULTI Y-Series.<br />

The Y-Series, just like the R2-Series, can condition up<br />

to 50 zones intelligently. The Y-Series takes advantage of<br />

<strong>Mitsubishi</strong> Electric’s INVERTER technology to deliver the<br />

precise amount of cooling or heating to all connected<br />

zones. By using T-branches and headers, the Y-Series<br />

provides the ultimate in piping design flexibility that is truly<br />

simple in application. The BC Controller is not used for<br />

Y-Series installations.<br />

The ultimate in zoning<br />

The CITY MULTI Y-Series uses a two-pipe system with a<br />

wide variety of indoor units and individual zone controllers to<br />

provide the ultimate zoning system. Headers and T-branches<br />

simplify the piping design and provide design freedom for<br />

placement of both piping and indoor units. Individual zones<br />

are managed by remote controllers placed in each zone or by<br />

the centralized controller. The BC Controller is not used for<br />

Y-Series installations.<br />

Heat Pump (Y- / WY- / S-Series)<br />

Intelligent energy usage<br />

The highly responsive INVERTER technology and customized<br />

individual zones of the CITY MULTI Y-Series provide year–<br />

round savings. In warm summer months, the Y-Series provides<br />

exceptional zoned cooling, and in cold winter months<br />

the INVERTER-driven compressor provides outstanding<br />

heating performance.<br />

CITY MULTI systems, in combination with <strong>Mitsubishi</strong><br />

Electric’s TG-2000 integrated system software configured with<br />

Tenant Billing, are able to monitor and log each zone’s energy<br />

usage via a networked PC.<br />

Larger projects, more options<br />

New to the modular outdoor unit design specifications is an<br />

option for either a 208/230V, 3-Phase, 60Hz powersource or a<br />

460V, 3-Phase, 60Hz power source. Another feature is larger<br />

capacities for the larger projects–to 30 tons–and an increased<br />

number of connectable indoor units–50–with increased line<br />

lengths. These capabilities increase the range<br />

of potential applications for which an architect, engineer or<br />

building owner cab specify CITY MULTI VRF systems.<br />

Increased pipe length<br />

The Y-Series two-pipe system offers great piping design flexibility.<br />

Two pipes run from the Y–series outdoor unit to connect up to<br />

50 indoor units via simple T-branches, headers, or combination<br />

of both. A Y-Series system may have a total combined length<br />

of refrigerant piping up to 3,280 feet one way. The farthest<br />

distance between the Y-Series outdoor unit and any one of the<br />

50 indoor units is 541 feet. The outdoor unit can be placed 164*<br />

feet vertically above the lowest indoor unit or 131 feet vertically<br />

below the highest indoor unit. The Y-Series offers exceptional<br />

line lengths that will accommodate just about any commercial<br />

application, including multi-story office buildings, universities, and<br />

many, many others.<br />

Refrigerant piping lengths<br />

Total length ............................................................3,280<br />

Maximum feet<br />

Farthest indoor from outdoor ..............................541 (623 equivalent)<br />

Farthest indoor unit from first branch ...................134 – 184<br />

Vertical differentials between units<br />

Indoor/outdoor (outdoor higher) ...........................164*<br />

Indoor/outdoor (outdoor lower).............................131<br />

Indoor/BC controller (single/main) ........................49<br />

- Maximum length between single/main BC controller and<br />

indoor is dependent upon the vertical differential between<br />

the single/main BC controller and the indoor unit.<br />

Indoor/indoor .........................................................49<br />

Main BC Controller/Sub BC Controller ................49<br />

Maximum feet<br />