Y-SERIES OVERVIEW<br />
CITY MULTI ® Y-Series:<br />
The two-pipe zoned<br />
system designed for<br />
heat pump operation<br />
Y-Series outdoor units are flexible enough<br />
to cool or heat up to 50 individual zones,<br />
maximizing building design options.<br />
They feature low operating sound, easy<br />
piping and maintenance design, and light<br />
weight. Y-Series units are available in<br />
both 208/230V and 460V up to 30 tons<br />
for different applications, (6-20 ton units<br />
meet ENERGY STAR ® Light Commercial<br />
Requirements and will exceed proposed<br />
ASHRAE 90.1 efficiency ratings for 2010).<br />
Design flexibility<br />
Flexibility is the key with the CITY MULTI Y-Series.<br />
The Y-Series, just like the R2-Series, can condition up<br />
to 50 zones intelligently. The Y-Series takes advantage of<br />
<strong>Mitsubishi</strong> Electric’s INVERTER technology to deliver the<br />
precise amount of cooling or heating to all connected<br />
zones. By using T-branches and headers, the Y-Series<br />
provides the ultimate in piping design flexibility that is truly<br />
simple in application. The BC Controller is not used for<br />
Y-Series installations.<br />
The ultimate in zoning<br />
The CITY MULTI Y-Series uses a two-pipe system with a<br />
wide variety of indoor units and individual zone controllers to<br />
provide the ultimate zoning system. Headers and T-branches<br />
simplify the piping design and provide design freedom for<br />
placement of both piping and indoor units. Individual zones<br />
are managed by remote controllers placed in each zone or by<br />
the centralized controller. The BC Controller is not used for<br />
Y-Series installations.<br />
Heat Pump (Y- / WY- / S-Series)<br />
Intelligent energy usage<br />
The highly responsive INVERTER technology and customized<br />
individual zones of the CITY MULTI Y-Series provide year–<br />
round savings. In warm summer months, the Y-Series provides<br />
exceptional zoned cooling, and in cold winter months<br />
the INVERTER-driven compressor provides outstanding<br />
heating performance.<br />
CITY MULTI systems, in combination with <strong>Mitsubishi</strong><br />
Electric’s TG-2000 integrated system software configured with<br />
Tenant Billing, are able to monitor and log each zone’s energy<br />
usage via a networked PC.<br />
Larger projects, more options<br />
New to the modular outdoor unit design specifications is an<br />
option for either a 208/230V, 3-Phase, 60Hz powersource or a<br />
460V, 3-Phase, 60Hz power source. Another feature is larger<br />
capacities for the larger projects–to 30 tons–and an increased<br />
number of connectable indoor units–50–with increased line<br />
lengths. These capabilities increase the range<br />
of potential applications for which an architect, engineer or<br />
building owner cab specify CITY MULTI VRF systems.<br />
Increased pipe length<br />
The Y-Series two-pipe system offers great piping design flexibility.<br />
Two pipes run from the Y–series outdoor unit to connect up to<br />
50 indoor units via simple T-branches, headers, or combination<br />
of both. A Y-Series system may have a total combined length<br />
of refrigerant piping up to 3,280 feet one way. The farthest<br />
distance between the Y-Series outdoor unit and any one of the<br />
50 indoor units is 541 feet. The outdoor unit can be placed 164*<br />
feet vertically above the lowest indoor unit or 131 feet vertically<br />
below the highest indoor unit. The Y-Series offers exceptional<br />
line lengths that will accommodate just about any commercial<br />
application, including multi-story office buildings, universities, and<br />
many, many others.<br />
Refrigerant piping lengths<br />
Total length ............................................................3,280<br />
Maximum feet<br />
Farthest indoor from outdoor ..............................541 (623 equivalent)<br />
Farthest indoor unit from first branch ...................134 – 184<br />
Vertical differentials between units<br />
Indoor/outdoor (outdoor higher) ...........................164*<br />
Indoor/outdoor (outdoor lower).............................131<br />
Indoor/BC controller (single/main) ........................49<br />
- Maximum length between single/main BC controller and<br />
indoor is dependent upon the vertical differential between<br />
the single/main BC controller and the indoor unit.<br />
Indoor/indoor .........................................................49<br />
Main BC Controller/Sub BC Controller ................49<br />
Maximum feet<br />
22