PWFY-P-NMU-E-AU/BU SPECIFICATIONS<br />

Model Name PWFY-P36NMU-E-AU PWFY-P72NMU-E-AU PWFY-P36NMU-E-BU<br />

Power Source<br />

208/230V, 1-phase, 60Hz<br />

Cooling Capacity *1 Btu/h 36,200 72,000 -<br />

Heating Capacity *1 Btu/h 39,900 79,800 39,900<br />

Power<br />

Consumption<br />

Current<br />

External Finish<br />

Cooling W 15 N/A<br />

Heating W 15 2,480<br />

Cooling A 0.072 / 0.065 N/A<br />

Heating A 0.072 / 0.065 12.30 /11.12<br />

Galvanized-steel Sheet<br />

Height In. 31-1/2<br />

Dimensions<br />

Width In. 17-3/4<br />

Depth In. 11-13/16<br />

Net Weight Unit Pounds 78 84 133<br />

Operating Inlet Water<br />

Temp. Range<br />

Cooling 50° F to 95° F -<br />

Heating 50° F to 105° F 50° F to 160° F<br />

Circulating Water Operation Volume Range GPM (L/m) 3-9 (10-35) 5-18 (20-72) 3-9 (10-35)<br />

Circulating Water Design Pressure MPa (psi) 1 (145)<br />

Water Piping<br />

Dimensions<br />

Inlet In. 3/4 FPT 1 FPT 3/4 FPT<br />

Outlet In. 3/4 FPT 1 FPT 3/4 FPT<br />

Refrigerant Pipe<br />

Dimensions<br />

Low Pressure (Brazed) In. 5/8 3/4 5/8<br />

High Pressure (Brazed) In. 3/8 3/8 3/8<br />

Drainpipe Dimensions (O.D.) In. 1-1/4<br />

Sound Pressure Levels dB(A) 29 44<br />

Connectable Outdoor Units<br />

PURY-P72~240T/Y(S)HMU (-BS),<br />

PURY-P72~288T/Y(S)JMU (-BS),<br />

PQRY-P72~240T/Y(S)HMU (-BS),<br />

PUHY-P72~P360T/Y(S)HMU (-BS),<br />

PUHY-P72~360T/Y(S)JMU (-BS),<br />

PQHY-P72~360T/Y(S)HMU (-BS)<br />

PURY-P72~240T/Y(S)HMU (-BS),<br />

PURY-P72~288T/Y(S)JMU (-BS),<br />

PQRY-P72~240T/Y(S)HMU (-BS)<br />

*1 Cooling/Heating Capacity indicates the maximum value at operation under the following conditions:<br />

Cooling: Inlet water temperature : 74° F; Outdoor: 95° F (35°C) DB; Water flow rate: 9.25 GPM<br />

Heating: Inlet water temperature: 86° F (30°C); Outdoor: 47° F (8°C) DB / 43° F (6°C) WB; Water flow rate: 9.25 GPM<br />

*2 Airflow rate/sound pressure levels are at Low-Mid1-Mid2-Hi, Low-Mid-Hi, or Low-Hi<br />

Ventilation Air: Providing sufficient ventilation air is an important part of very building design. ASHRAE Standard 62 provides the minimum air requirements. Also check local codes.<br />

Specifications are subject to change.<br />

WATER HEATING<br />

PURY-P120YHMU-A<br />

BC CONTROLLER<br />

PWFY-P38NMU-E-BU<br />

PWFY-P36NMU-E-BU<br />

PWFY-P36NMU-E-BU PEFY-P15NMHU-E PEFY-P24NMSU-E<br />

Water Supply<br />

Cold Water Tank<br />

Hot Water Tank<br />

For Cooling<br />

(AHU, FCU, etc)<br />

For Heating<br />

(AHU, FCU,<br />

Floor Heating, etc)<br />

Water Supply<br />

For Sanitary Use<br />

(Shower, Bath, etc)<br />

39

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!