Extended temperature range<br />
The updated WR2 and WY series CITY MULTI water source<br />
units can now handle entering water temperatures down<br />
to 23 o F in both heating and cooling mode allowing more<br />
possibilities for geothermal applications. Coupling the water<br />
source units with a geothermal loop will not only provide the<br />
benefit of higher efficiencies by using a lower entering water<br />
temperature, but will also provide all the benefit of an inverter<br />
driven CITY MULTI system. Running the loop temperatures<br />
colder when the system is operating in cooling mode reduce<br />
the power required by the outdoor units by as much as 35%.<br />
Because the ground remains relatively unaffected by outdoor<br />
ambient temperatures, the loop can be run at temperatures<br />
lower than ambient throughout the cooling season, and<br />
higher than ambient throughout the heating season. By<br />
running the loop at lower temperatures in the cooling season,<br />
the system becomes more efficient and by running the loop<br />
at higher temperatures during the heating season, it may<br />
reduce or remove the requirement for an auxiliary boiler to<br />
supplement the system.<br />
WR2/WY<br />
23˚F<br />
In cooling mode<br />
23˚F<br />
-13˚F -4˚F<br />
14˚F 32˚F 50˚F 68˚F 86˚F 104˚F<br />
Inlet Water Temperature<br />
Water temperature<br />
Water temperature<br />
CITY MULTI Systems and<br />
geothermal applications<br />
In heating mode<br />
113˚F<br />
113˚F<br />
CITY MULTI water cooled systems used in geothermal<br />
applications work by taking heat or rejecting heat from/to the<br />
ground. Closed loop systems accomplish this by circulating<br />
water through a series of wells or loops that are installed in<br />
the ground. This effectively turns the ground into a large heat<br />
exchanger.<br />
Available tax credits<br />
Coupling the CITY MULTI system with a ground source<br />
loop could qualify the entire system for a 10% commercial<br />
tax credit provided that the building meets the following<br />
requirements:<br />
• The system was placed in service between 10/3/2008 –<br />
12/31/2016<br />
• The building owner is not tax exempt<br />
• The building is located in the United States<br />
If the building meets these requirements, the building owner<br />
may be able to claim a 10% tax credit for the total installed<br />
cost of CITY MULTI geothermal system.<br />