CITY MULTI ® CONTROLLERS<br />
Wireless MA Remote Controller (PAR-FL32MA) and Receiver (PAR-FA32MA)<br />
• Features user-friendly operation and monitoring<br />
• Controls up to 16 indoor units in a single group<br />
• User Function: Allows user to set:<br />
- On/Off<br />
- operation modes of Cool, Heat, Dry, Fan or<br />
Auto (R2-Series only)<br />
- set temperature from 57˚ F – 87˚ F, depending on<br />
operation mode and indoor unit<br />
- fan speed setting<br />
- airflow direction<br />
• Grouping: Can be used only in same group<br />
with PAC-YT51 (Simple MA Remote Controller), PAR-21MAA<br />
(Deluxe MA Remote Controller), and other PAR-FL32MA<br />
(Wireless MA Remote Controllers)<br />
• Addressing: No addressing required<br />
• Wiring: Connects using two stranded, non-polar control<br />
wires to TB15 connection terminal on the indoor unit.<br />
Requires crossover wiring for grouping across indoor units<br />
• Dimensions: Remote (2-5/16" x 3/4" x 5-1/4"),<br />
Receiver (2-3/4" x 7/8" x 4-12/16")<br />
(Receiver (PAR-FA32MA) not shown)<br />
On/Off Controller (PAC-YT40ANRA)<br />
• On/Off Control for up to 16 Groups (max. of 50<br />
indoor units)<br />
• Collective On/Off Button turns all units on/off; collective<br />
LED displays if any units are on, off, or in error<br />
• Individual On/Off Button for 16 groups of indoor units;<br />
Turns individual group on/off; Individual LED displays if<br />
any units in the group are on, off, or in error<br />
• Diagnostics: Flashing LED indicates error.<br />
Displays four-digit error code<br />
• Addressing: Requires manual addressing using rotary dial<br />
switch to the M-NET communication bus<br />
(default address is 201)<br />
• Wiring: Connects to TB7 connection terminal on outdoor<br />
unit via PAC-SC50KUA power supply or connects to<br />
TB3 connection terminal on outdoor unit<br />
• Dimensions: 5-1/8" x 3/4" x 4-3/4"<br />
• Recommended to be used in conjunction with<br />
PAR-21MAA Deluxe MA Remote Controllers or<br />
PAR-F27MEA ME Remote Controllers for temperature<br />
and mode setting<br />
• Expandability: External input signal can be used for batch<br />
operation such as Emergency Stop, On/Off, or On/Off<br />
plus prohibit of local remote controller operation, external<br />
output signal for collective operation state or error state<br />
Schedule Timer (PAC-YT34STA)<br />
• Schedules up to 50 indoor units. Maximum number of<br />
indoor units per one group is 16. Maximum number of<br />
groups is 50<br />
• Use only in conjunction with PAR-21MAA (Deluxe MA<br />
Remote Controllers) or PAR-F27MEA (ME Remote<br />
Controllers)<br />
• Scheduling: Supports up to nine patterns with up to 16<br />
operations per pattern; operations include On/Off, mode<br />
selection (Cool, Heat), set temperature, and prohibition<br />
of remote controller functions (On/Off, operation mode<br />
change, and set temperature adjustment); patterns are<br />
applied to each group of indoor units on a per-day basis;<br />
minimum time interval is five minutes<br />
• Diagnostics: Displays four-digit error code and<br />
error unit address<br />
• Addressing: Requires manual addressing using rotary dial<br />
switch to the M-NET communication bus.<br />
• Wiring: Connects to TB7 connection terminal on outdoor<br />
unit with the PAC-SC50KUA power supply or connects<br />
to TB3 connection terminal on outdoor unit<br />
• Dimensions: 5-1/8" x 3/4" x 4-3/4"<br />
• Expandability: Can be used in conjunction with AG-150<br />
Centralized Controller, which has higher priority but<br />
requires change in dip-switch setting. Can be used in<br />
conjunction with external input/output signals<br />